Elda F. Saunderson

Elda F. Saunderson

Auto-generated profile, based on publicly available information

Elda F. Saunderson

South African National Space Agency, Hermanus, South Africa

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MJMichal Janošek
Michal Janošek
MBMattia Butta
Mattia Butta
MDMichal Dressler
Michal Dressler
ESElda Saunderson
Elda Saunderson
DNDavid Novotný
David Novotný
CFCoenrad Fourie
Coenrad Fourie

16 December 2014 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
TMThabang Matladi
Thabang Matladi
ESElda F Saunderson
Elda F Saunderson
DGDaniel J Gouws
Daniel J Gouws
TPTemwanijoshua Phiri
Temwanijoshua Phiri
CKChristian Kwisanga
Christian Kwisanga
CFC J Fourie
C J Fourie
There has always been a need to monitor the near Earth's magnetic field, as this monitoring provides understanding and possible predictions of Space Weather events such as geomagnetic storms. Conventional magnetometers such as fluxgates have been used for decades for Space Weather research. The use of highly sensitive magnetometers such as Superconducting QUantum Interference Devices (SQUIDs), promise to give more insight into Space Weather. SQUIDs are relatively recent types of magnetometers that exploit the superconductive effects of flux quantization and Josephson tunneling to measure magnetic flux. SQUIDs have a very broad bandwidth compared to most conventional magnetometers and can measure magnetic flux as low as a few femtotesla. Since SQUIDs have never been used in Space Weather research, unshielded, it is necessary to investigate if they can be reliable Space Weather instruments. The validation is performed by comparing the frequency content of the SQUID and fluxgate magnetometers, as reported by Phiri [1].

26 September 2019 in IEEE Magnetics Letters
Verified
Journal Article
Open access
MJMichal Janošek
Michal Janošek
ESElda F. Saunderson
Elda F. Saunderson
MDMichal Dressler
Michal Dressler
DGDaniel J. Gouws
Daniel J. Gouws
Capabilities for calibrations of angular deviations of sensor triplets in precise magnetometers were evaluated in a 2.5-metre, triaxial Helmholtz-coil facility. The coil system is located in a magnetically quiet environment at SANSA Space Science in Hermanus, South Africa. The angular calibration results obtained from the “thin-shell” calibration procedure were compared with direct measurements on a non-magnetic tilting/rotational platform. One-year expanded uncertainty of angular deviation calibrations is estimated as $6 \times 10^{-2}$ degrees of arc; $3 \times 10^{-3}$ degrees are possible when doing a numerical re-calibration and correction on a short-term basis. In addition, an approach for obtaining body-to-sensor angular calibrations is presented, allowing for speed-up of the calibrations and possibly increasing their accuracy and repeatability by avoiding alignment to the coils by a laser beam and leveling.

8 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ESElda F. Saunderson
Elda F. Saunderson
MJMichal Janošek
Michal Janošek
MDMichal Dressler
Michal Dressler
ANAmoré E. Nel
Amoré E. Nel
SLStefan I. Lotz
Stefan I. Lotz
CFCoenrad J. Fourie
Coenrad J. Fourie
A High Temperature Superconductor (HTS) SQUID magnetometer is located at the INTERMAGNET Hermanus Magnetic Observatory (HER) site in South Africa. The LN 2 -cooled SQUID is operated unshielded and records the geomagnetic field continuously. If validated, the SQUID may be used as a space weather instrument. The SQUID records small geomagnetic variations such as pulsations, which are short period fluctuations of the geomagnetic field at ULF frequencies. Although the SQUID magnetometers are about 10× more sensitive than fluxgate magnetometers, it is running in an urban environment contaminated by anthropogenous noise. It was also found that one of the SQUIDs is prone to thermally induced oscillations due to thermo-acoustic oscillations in the dewar. To distinguish pulsations from uncorrelated noise, the SQUID data is correlated with fluxgate data from the two closest INTERMAGNET observatories, Hartebeesthoek (HBK) and Keetmanshoop (KMH), both located more than 1000 km away. Man-made noise and SQUID oscillations should give low coherence between SQUID/KMH and SQUID/HBK pairs. Coherence higher than 0.9 was found when pulsations were present in the data and the algorithm has also proven effective on data contaminated with the thermal SQUID oscillations.

1 January 2024
Verified
Conference Paper
Open access
PDF file
ESE. Saunderson
E. Saunderson
DGD. Gouws
D. Gouws
MJM. Janosek
M. Janosek
Torquer rods for commercial spacecraft need to be characterized for qualification purposes. Very accurate characterization is possible using lengthy methods with accurate mechanical specifications, however, in the commercial environment this is not feasible. Three characterization methods, two magnetometric and one fluxmetric, are evaluated on robustness and uncertainty.