Jianfeng Zhou

Jianfeng Zhou

Auto-generated profile, based on publicly available information

Jianfeng Zhou

Department of Emergency Medicine, The First Medical Center of the Chinese People’s Liberation Army General Hospital, 100853 Beijing, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JLJiantao Li
Jiantao Li
MWMenglin Wang
Menglin Wang
JZJianfeng Zhou
Jianfeng Zhou
LHLin Han
Lin Han
HZHao Zhang
Hao Zhang
MHMing Hao
Ming Hao
Objectives. In the present study, we evaluated the mechanical outcome of different configurations of cannulated compression screws for the fixation of Pauwels type III femoral neck fracture and the stress distribution around the holes corresponding to fixation protocol after screws removal. Methods. The Pauwels type III of femoral neck fracture was created in 3-matic software and the models of cannulated compression screws were constructed using UG-NX software. Five fixation systems were assembled to the fracture models. Abaqus software was used to perform the process of finite element analysis. Values of stress distribution, maximum stress, model principal strains of proximal fragment, and stress distribution around the holes of femur model were recorded. Results. Stress of cannulated compression screws was intensely focused on the middle area of the screw near the fragment of each group. Inverted triangle model showed the highest peak stress on screws under different phases of load. Each screw dispersed some stresses, but at least one underwent the peak stress. Fracture model fixed by inverted triangle configuration showed the lowest volume of yielding strain in the proximal fragment. The area of higher stress around the holes was largest after triangle screws removal when compared with other four models. Conclusions. Our study indicated that different cannulated compression screws fixation configurations for the unstable femoral neck fractures showed the different mechanical efficiency. Inverted triangular configuration showed the mechanical advantage and being less likely to cutout. The fixation strategy of triangle configuration was least recommended if patients tended to remove the implants.

17 July 2026 in The Heart Surgery Forum
Verified
Journal Article
Open access
PDF file
JZJianfeng Zhou
Jianfeng Zhou
RZRenzheng Zhang
Renzheng Zhang
ZZZiyi Zhang
Ziyi Zhang
LYLing Yang
Ling Yang
DXDi Xie
Di Xie
Background:Complex acute type B aortic dissection (ATBAD) is an aortic emergency associated with high mortality. Thoracic endovascular aortic repair (TEVAR) has become the treatment of choice for complex ATBAD. However, early acute heart failure (AHF) after TEVAR can significantly increase perioperative mortality risk, and systematic studies on its incidence, multidimensional risk factors, and independent impact on mid- and long-term prognosis remain insufficient.Methods:A total of 225 patients with complex ATBAD who underwent TEVAR at our hospital from January 2021 to January 2025 were prospectively enrolled. Patients were divided into an AHF group (n = 34) and a non-AHF group (n = 191) according to whether AHF occurred within 30 days postoperatively. Baseline data, imaging characteristics, laboratory parameters, and perioperative data were collected. Univariable and multivariable binary logistic regression analyses were used to identify independent risk factors for AHF. Receiver operating characteristic (ROC) curves were plotted to evaluate predictive performance, and internal validation was conducted using Bootstrap resampling (B = 1000); Kaplan-Meier analysis and Cox proportional hazards regression (Fine-Gray competing risks model) were used to assess the impact of AHF on 1-year all-cause mortality.Results:Among 225 patients, the incidence of AHF within 30 days after TEVAR was 15.1% (34/225). Multivariable logistic regression identified four independent risk factors: preoperative B-type natriuretic peptide (BNP) ≥100 pg/mL (odds ratio [OR] = 7.84, 95% confidence interval [CI] 3.12–19.68), concomitant coronary artery disease (CAD) (OR = 3.10, 95% CI 1.05–9.13), admission heart rate per 10 beats/min increase (OR = 1.72, 95% CI 1.28–2.31), and stent coverage length per 10 mm increase (OR = 1.14, 95% CI 1.04–1.25) (all p < 0.05). The combined prediction model constructed from these four factors achieved an area under the curve (AUC) of 0.897 (95% CI 0.842–0.952); Bootstrap-corrected AUC was 0.868 (95% CI 0.801–0.935); the AUC for preoperative BNP alone was 0.842 (optimal cutoff 98.5 pg/mL). The AHF group had significantly higher 30-day all-cause mortality (17.6% vs 2.6%, p = 0.002) and 30-day major adverse cardiac and cerebrovascular events (MACCE) rate (35.3% vs 9.4%, p < 0.001) than the non-AHF group. Kaplan-Meier analysis showed a lower 1-year cumulative survival rate in the AHF group (73.5%) compared with the non-AHF group (93.7%, Log-rank p < 0.001). After adjusting for confounders, AHF remained an independent risk factor for 1-year all-cause mortality (hazard ratio [HR] = 4.32, 95% CI 1.86–10.04, p = 0.001).Conclusions:The incidence of early AHF after TEVAR in complex ATBAD patients is 15.1%. Preoperative BNP ≥100 pg/mL, concomitant CAD, elevated admission heart rate, and longer stent coverage length are independent risk factors. AHF independently increases perioperative and 1-year all-cause mortality risk.