Jiantao Li

Jiantao Li


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2024 in Cell Host & Microbe
Verified
Journal Article
Closed access
XZXiaoqiang Zhu
Xiaoqiang Zhu
XHXiaowen Huang
Xiaowen Huang
MHMuni Hu
Muni Hu
RSRongrong Sun
Rongrong Sun
JLJiantao Li
Jiantao Li
HCHaoyan Chen
Haoyan Chen

9 June 2022 in Cells
Verified
Journal Article
Open access
PDF file
JDJunhao Deng
Junhao Deng
FMFanqi Meng
Fanqi Meng
KZKexue Zhang
Kexue Zhang
JGJianpeng Gao
Jianpeng Gao
ZLZhong-yang Liu
Zhong-yang Liu
PTPeifu Tang
Peifu Tang
Microglia, as the resident immune cells and first responder to neurological insults, play an extremely important role in the pathophysiological process of spinal cord injury. On the one hand, microglia respond rapidly and gather around the lesion in the early stage of injury to exert a protective role, but with the continuous stimulation of the injury, the excessive activated microglia secrete a large number of harmful substances, aggravate the injury of spinal cord tissue, and affect functional recovery. The effects of microglia depletion on the repair of spinal cord injury remain unclear, and there is no uniformly accepted paradigm for the removal methods and timing of microglia depletion, but different microglia depletion strategies greatly affect the outcomes after spinal cord injury. Therefore, this review summarizes the physiological and pathological roles of microglia, especially the effects of microglia depletion on spinal cord injury—sustained microglial depletion would aggravate injury and impair functional recovery, while the short-term depletion of microglial population in diseased conditions seems to improve tissue repair and promote functional improvement after spinal cord injury. Furthermore, we discuss the advantages and disadvantages of major strategies and timing of microglia depletion to provide potential strategy for the treatment of spinal cord injury.

9 December 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JLJiantao Li
Jiantao Li
MWMenglin Wang
Menglin Wang
JZJianfeng Zhou
Jianfeng Zhou
LHLin Han
Lin Han
HZHao Zhang
Hao Zhang
MHMing Hao
Ming Hao
Objectives. In the present study, we evaluated the mechanical outcome of different configurations of cannulated compression screws for the fixation of Pauwels type III femoral neck fracture and the stress distribution around the holes corresponding to fixation protocol after screws removal. Methods. The Pauwels type III of femoral neck fracture was created in 3-matic software and the models of cannulated compression screws were constructed using UG-NX software. Five fixation systems were assembled to the fracture models. Abaqus software was used to perform the process of finite element analysis. Values of stress distribution, maximum stress, model principal strains of proximal fragment, and stress distribution around the holes of femur model were recorded. Results. Stress of cannulated compression screws was intensely focused on the middle area of the screw near the fragment of each group. Inverted triangle model showed the highest peak stress on screws under different phases of load. Each screw dispersed some stresses, but at least one underwent the peak stress. Fracture model fixed by inverted triangle configuration showed the lowest volume of yielding strain in the proximal fragment. The area of higher stress around the holes was largest after triangle screws removal when compared with other four models. Conclusions. Our study indicated that different cannulated compression screws fixation configurations for the unstable femoral neck fractures showed the different mechanical efficiency. Inverted triangular configuration showed the mechanical advantage and being less likely to cutout. The fixation strategy of triangle configuration was least recommended if patients tended to remove the implants.

9 February 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
HLHua Li
Hua Li
DWDaofeng Wang
Daofeng Wang
WZWupeng Zhang
Wupeng Zhang
GXGaoxiang Xu
Gaoxiang Xu
CXCheng Xu
Cheng Xu
JLJiantao Li
Jiantao Li
Objective: The systematic review aimed to determine the potential side effects of antibacterial coatings in orthopaedic implants.Methods: Publications were searched in the databases of Embase, PubMed, Web of Science and Cochrane Library using predetermined keywords up to 31 October 2022. Clinical studies reporting side effects of the surface or coating materials were included.Results: A total of 23 studies (20 cohort studies and three case reports) reporting the concerns about the side effects of antibacterial coatings were identified. Three types of coating materials, silver, iodine and gentamicin were included. All of studies raised the concerns regarding safety of antibacterial coatings, and the occurrence of adverse events was observed in seven studies. The main side effect of silver coatings was the development of argyria. For iodine coatings, only one anaphylactic case was reported as an adverse event. No systemic or other general side effects were reported for gentamicin.Conclusion: Clinical studies on the side effects of antibacterial coatings were limited. Based on the available outcomes, the most reported side effects of antibacterial coatings in clinical use were argyria with silver coatings. However, researchers should always pay attention to the potential side effects of antibacterial materials, such as systematic or local toxicity and allergy.

27 May 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
RZRu-Yi Zhang
Ru-Yi Zhang
XSXiu yun Su
Xiu yun Su
JZJingxin Zhao
Jingxin Zhao
JLJiantao Li
Jiantao Li
LZLicheng Zhang
Licheng Zhang
PTPeifu Tang
Peifu Tang
Background: The femoral neck torsion angle (FNTA) is an important but often neglected parameter in assessments of the anatomical morphology of the femoral neck, which is often confused with the femoral neck anteversion angle (FNAA) in the current literature. Currently, the measurement methods reported in the literature all adopt the naked eye or two-dimensional (2D) visualization method, and the measurement parameters and details are not clearly defined. The objection of this research was to provide a reliable 3D method for determining the femoral neck axis, to improve the measurement method of the FNTA, and to analyze the anatomical and clinical significance of the results. Methods: Computed tomography (CT) data of 200 patients who received a lower extremity CT angiography examination were selected, and the bilateral femurs were reconstructed with three dimensional CT (3D CT). First, the 3D axis of the femoral neck was built. Second, the long axis of the cross section the femoral neck isthmus (FNI) and femoral neck basilar part (FNB) were confirmed by the “inertia axes” method, and the plane consisting of the long axis of the cross-section and the center of the femoral head was defined as the long axial plane. Third, the coronal plane of the proximal femur was determined through the long axis of the proximal femur and the femoral coronal. Finally, the FNTAs (the angles between the long axial planes and the coronal plane of the proximal femur) of FNI and FNB were measured. The size of FNTA was compared between the sexes and sides and different locations, the correlation between the parameters and age, height, and weight were evaluated. Results: The difference in FNTA was statistically significant between the isthmus and the basilar part (isthmus 30.58 ± 8.90° vs. basilar part 23.79 ± 3.98°; p < 0.01). Significant difference in the FNTA was observed between the sexes (males 31.99 ± 9.25° vs. females 27.49 ± 7.19°; p < 0.01). The increase in FNTA from the basilar part to the isthmus was 6.79 ± 8.06°, and the male (7.87 ± 8.57°) was greater than the female (4.44 ± 6.23°, p < 0.01). However, no significant difference in the values was observed between sides. Height exerted the greatest effect on the FNTA according to the correlation analysis (r = 0.255, p< 0.001). Conclusions: This study found a reliable 3D method for the determination of the femoral neck axis improved the measurement method of the FTNTA and made it more accurate and repeatable. The results provided a methodological basis and theoretical support for the research and development of internal fixation device for femoral neck fracture and the spatial configuration of implants in treatment. And the optimal opening point of the femoral medullary cavity was recommended to locate at the posterior position of the top of the femoral neck cross-section during hip replacement.

16 September 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
HChua chen
hua chen
PYPeng Yin
Peng Yin
SWSong Wang
Song Wang
JLJiantao Li
Jiantao Li
LZLihai Zhang
Lihai Zhang
PTPeifu Tang
Peifu Tang
Objective. The objective of this study was to compare the clinical outcomes and complications between the locking compression plate (LCP) and LCP with fibular allograft in the treatment of patients with displaced proximal humerus fracture (PHF) in elderly people. Material and Methods. Between January 2010 and December 2013, a total of 97 elderly patients with displaced PHF were treated by LCP or LCP with fibular allograft, and finally 89 patients were included in our study. All the patients were divided into Group I (patients treated by LCP) and Group II (patients treated by LCP with fibular allograft). Function results were assessed by the disability of the arm, shoulder, and hand (DASH) score and Constant-Murley score (CMS), and complications were also recorded in each group. Results. The average follow-up was 35.2 months (range, 24-48 months) in Group I and 33.5 months (range, 24-48 months) in Group II. DASH in patients of Group I was significantly higher than that in patients in Group II and patients of Group I had CMS scores significantly lower than patients in Group II (P5mm were significantly higher in Group I than in Group II (P<0.05). Conclusions. The present results showed that that patients treated by LCP with fibular allograft had a better functional outcome and a lower complication rate compared to patients treated by LCP alone. Suitable void filler in the proximal humerus for supporting the head fragment, medial cortical bone, and greater tuberosity might play a key role in reducing the incidence of the complications in elderly patients, especially with osteoporosis.