Aikaterini Gialopsou

Aikaterini Gialopsou

Auto-generated profile, based on publicly available information

Aikaterini Gialopsou

University of Nottingham

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2024 in Quantum Science and Technology
Verified
Journal Article
Open access
TCT Coussens
T Coussens
AGA Gialopsou
A Gialopsou
CAC Abel
C Abel
MBM G Bason
M G Bason
TJT M James
T M James
PKP Krüger
P Krüger
To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers. This system is designed and built to facilitate fast prototyping and testing of new measurement schemes by enabling quick reconfiguration of the self-contained laser and sensor modules as well as allowing for the construction of various array layouts with a shared light source. The modularity of this system facilitates the development of methods for managing high-density arrays for magnetic imaging. The magnetometer sensitivity and bandwidth are first characterised in both individual channel and differential gradiometer configurations before testing in a real-world magnetoencephalography environment by measuring alpha rhythms from the brain of a human participant. We demonstrate the OPM system in a first-order axial gradiometer configuration with a magnetic field gradient sensitivity of 10 fT / cm / Hz at a baseline of 4.5 cm. Single-channel operation achieved a sensitivity of 65 fT / Hz . Bandwidths exceeding 200 Hz were achieved for two independent modules. The system’s increased temporal resolution allows for the measurement of spinal cord signals, which we demonstrate by using phantom signal trials and comparing with an existing commercial sensor.

28 January 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
AGAikaterini Gialopsou
Aikaterini Gialopsou
CAChristopher Abel
Christopher Abel
TJTimothy M. James
Timothy M. James
TCThomas Coussens
Thomas Coussens
MBMark G. Bason
Mark G. Bason
PKPeter Krüger
Peter Krüger
Recent developments in performance and practicality of optically pumped magnetometers have enabled new capabilities in non-invasive brain function mapping through magnetoencephalography. In particular the lack of need of cryogenic operating conditions allows for more flexible placement of the sensor heads closer to the brain surface, leading to improved spatial measurement resolution and increased source localisation capabilities. Through the recording of visually evoked brain fields (VEF), we demonstrate that the closer sensor proximity can be further exploited to improve the temporal resolution. We use optically pumped magnetometers (OPMs), and for reference superconducting quantum interference devices (SQUIDs), to measure brain responses to standard flash and pattern reversal stimuli. We find highly reproducible signals with consistency across multiple healthy participants, stimulus paradigms and sensor modalities. The temporal resolution advantage of OPMs is manifest in a fourfold improvement of the ratio of magnetic signal peak height to temporal width, compared to SQUIDs. The resulting capability of improved spatio-temporal signal tracing is illustrated by simultaneous vector recordings of VEFs in the primary (V1) and associative (V2) visual cortex, where a time lag on the order of 10-20 ms is consistently found. This paves the way for further studies of spatio-temporal neurophysiological signal tracking in visual stimulus processing and other brain responses with potentially far-reaching consequences for time-critical mapping of functionality in the healthy and pathological brains.

28 July 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
MHMairi Houlgreave
Mairi Houlgreave
AGAikaterini Gialopsou
Aikaterini Gialopsou
EBElena Boto
Elena Boto
MBMatthew J Brookes
Matthew J Brookes
SJStephen R. Jackson
Stephen R. Jackson
Tourette Syndrome (TS) is a neurodevelopmental hyperkinetic disorder characterised by involuntary tics. These tics are thought to arise due to hyperexcitability of the motor cortex due to disinhibition within the cortico-striato-thalamo-cortical pathway. Given the involvement of motor circuits in this disorder, we explored whether there is a difference in the oscillatory dynamics of voluntary movements in people with tic disorders. We recorded optically pumped magnetometer magnetoencephalography during cued voluntary finger abductions in individuals with tic disorders and age- and sex-matched neurotypical controls. We analysed the data both using conventional time frequency analysis and using hidden Markov modelling to explore the difference in beta burst characteristics and dynamics. Whilst no differences were seen between groups during conventional analysis, we demonstrated an increase in beta burst duration during the post-movement beta rebound within the contralateral motor cortex in individuals with TS suggestive of increased inhibition following movement. We also show evidence of increased contralateral sensorimotor functional connectivity and reduced connectivity from and between frontal regions, as measured using coincident beta bursts. This is suggestive of disrupted functional connectivity within frontal control networks in individuals with TS.