28 January 2019 in IEEE Transactions on Power Delivery
Mineral oil is traditionally used in liquid immersed transformers to act as a coolant, an information carrier, and as an electrical insulator. Emerging alternative transformer liquids provide advantages, such as improved fire safety and better biodegradability, of which transformer operators would like to utilize. In this paper, an experimental study is conducted to compare the thermal performance of a mineral hydrocarbon transformer oil, a gas-to-liquid hydrocarbon transformer oil, and a synthetic ester transformer liquid as coolants in a zig-zag disc type winding model. Comparisons are made under liquid directed cooling modes and under liquid natural cooling modes. It was found that under both cooling modes, the mineral based transformer oil and the gas-to-liquid based transformer oil behaved almost with comparable liquid flow and temperature distributions. Under liquid directed cooling modes, the synthetic ester gave more uniform flow distribution and delayed the occurrence of liquid reverse flow compared to the other oils. Under liquid natural cooling modes and using the zig-zag disc type winding model, synthetic ester, due to its higher viscosity which caused lower inlet flow rate to develop under the specific tested retrofilling conditions, caused less uniform oil flow distribution within the pass and higher hot spot temperature.
15 June 2016 in IEEE Transactions on Power Delivery
In this paper, a method for predicting pressure drop and flow distribution in disc-type transformer windings in an oil-forced and directed cooling mode is proposed. First, dimensional analyses are conducted to identify the independent dimensionless variables that affect pressure drop over and flow distribution in the winding. Next, parametric sweeps are performed with computational fluid dynamics simulations under isothermal flow conditions. Finally, pressure drop and flow distribution results obtained from the simulations are correlated with the previously identified dimensionless variables to derive correlation equations. These equations have been verified over a range of different isothermal and non-isothermal flow cases and applied to identify the criteria for the occurrence of reverse flow resulting from a combination of pass inlet flow rate and winding geometry. In addition, the method provides an insight into the controlling parameters to determine the minimum oil velocity in horizontal cooling ducts.
1 September 2019 in High Voltage
Failure of a transformer is a costly incident which can impact power system operation and result in loss of supply to customers. Transformers can fail through a number of mechanisms, one of which is from the formation of bubbles within the insulation. Currently, the loading guidance is set to avoid certain overload temperatures as high temperature is the main cause of bubbles forming. This paper analyses the limit set within the loading guides, comparing the most commonly cited temperature limit of 140°C with values taken from across the full spectra of available studies in literature. It is concluded that there is sufficient evidence for further investigation into formation of bubbles from transformer insulation as employing a single temperature limit may be inadequate. Use of a single temperature value is unsuitable, given the wide range of potential scenarios that the transformer fleet can present. It has become the go‐to rationale that the moisture content of the solid insulation is the key driver for transformer bubbling temperature. This is true, however, it is shown that other factors such as solid insulation aged condition (determined through degree of polymerisation value) and the insulation type are also important considerations.
1 March 2013 in IET Electric Power Applications
This study reports experimental studies of creepage discharges on the pressboard (PB) surface in esters under ac divergent electric field. With the help of commercial partial discharges detector, wideband current measurement and high‐speed image recorder, the differences of discharge patterns between open gap and on PB surface were studied in esters as well as in mineral oil. The results show that the presence of PB surface tends to promote discharges, especially negative discharges, and enables more discharges to occur at smaller phase angles. It is believed that the promotion effect of PB surface on discharges is caused by surface charges and bubble residences; because of more intense discharges and higher viscosity of esters, this effect is more significant in esters than in mineral oil.
29 June 2017 in IEEE Transactions on Power Delivery
The hot-spot factor (H) is a crucial component of the thermal diagram in IEC 60076-2 to derive the hot-spot temperature from the test data. In this paper, H is expressed as the sum of two separable components, one relating to convection in the fluid domain and the other relating to conduction in the solid domain. Dimensional analyses on fluid flow and heat transfer show that both components are functions of dimensionless winding geometry, loss distribution, Re and Pr. The relationship between H and Re and Pr for a fixed winding geometry with uniform loss distribution is obtained by conducting computational fluid dynamics (CFD) parametric sweeps and multilayer least-square based correlation. The correlation obtained is verified by the consistency between H from new CFD simulations and those from the correlation. For nonuniform loss distribution, H is a function of Re, Pr and the Q factor. When the hot-spot is at the location of the highest power loss, H is in a linear relationship with Q and this linear relationship is coupled with a nonlinear relationship between H and Re and Pr.