Gordon Wilson

Gordon Wilson

Auto-generated profile, based on publicly available information

Gordon Wilson

National Grid Electricity Transmission,Warwick,United Kingdom

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ADAtip Doolgindachbaporn
Atip Doolgindachbaporn
GCGeorge Callender
George Callender
PLPaul Lewin
Paul Lewin
ESEdward Simonson
Edward Simonson
GWGordon Wilson
Gordon Wilson
Condition monitoring of power transformers, which are key components of electrical power systems, is essential to identify incipient faults and avoid catastrophic failures. In this paper machine learning algorithms, i.e., nonlinear autoregressive neural networks and support vector machines, are proposed to model the transformer thermal behavior for the purpose of monitoring. The thermal models are developed based on the historical measurements from nine transformers comprised of two 180-MVA units, four 240-MVA units and three 1000-MVA units. The data consist of load profile, tap position, winding indicator temperature (WTI) measurement, ambient temperature, wind speed and solar radiation. The results are validated against field measurements, and it is clearly demonstrated that the alternative algorithms surpass the IEEE Annex G thermal model. An incipient thermal fault identification algorithm is then proposed and successfully used to identify an issue using measurements taken in the field. This algorithm could be used to alert the operator and plan intervention accordingly.

1 September 2019 in High Voltage
Verified
Journal Article
Open access
PDF file
JHJames Hill
James Hill
ZWZhongdong Wang
Zhongdong Wang
QLQiang Liu
Qiang Liu
CKChristoph Krause
Christoph Krause
GWGordon Wilson
Gordon Wilson
Failure of a transformer is a costly incident which can impact power system operation and result in loss of supply to customers. Transformers can fail through a number of mechanisms, one of which is from the formation of bubbles within the insulation. Currently, the loading guidance is set to avoid certain overload temperatures as high temperature is the main cause of bubbles forming. This paper analyses the limit set within the loading guides, comparing the most commonly cited temperature limit of 140°C with values taken from across the full spectra of available studies in literature. It is concluded that there is sufficient evidence for further investigation into formation of bubbles from transformer insulation as employing a single temperature limit may be inadequate. Use of a single temperature value is unsuitable, given the wide range of potential scenarios that the transformer fleet can present. It has become the go‐to rationale that the moisture content of the solid insulation is the key driver for transformer bubbling temperature. This is true, however, it is shown that other factors such as solid insulation aged condition (determined through degree of polymerisation value) and the insulation type are also important considerations.

5 July 2011 in IET Electric Power Applications
Verified
Journal Article
Closed access
ZWZ.D. Wang
Z.D. Wang
QLQiang Liu
Qiang Liu
XWX. Wang
X. Wang
PJP. Jarman
P. Jarman
GWG. Wilson
G. Wilson
IEC 60897 (determination of lightning impulse breakdown voltage, LIBV) and IEC 61294 (determination of partial discharge inception voltage, PDIV) are designed with the purpose of evaluating insulating liquids' electrical property in a divergent field, and their current versions have existed for about two decades without revision. In view of the interest in the use of natural and synthetic esters in transformers, the suitability of IEC 60897 and IEC 61294 to evaluate new insulating liquids and the potential revisions are discussed here. Through comparative tests of mineral oil and esters, it is proposed that for IEC 60897, V–T (breakdown voltage–time to breakdown) curve should be obtained at overstressed voltages, i.e. voltages higher than LIBV, preferably under positive polarity, as a complement of LIBV. Similarly for IEC 61294, counting partial discharge (PD) numbers at overstressed voltages, i.e. voltages higher than PDIV, is proposed as a complement of PDIV. Overall, overstressing the liquids helps provide more information about electrical property of insulating liquid and thus can better assess a liquid for the purpose of insulation design. According to the above proposed procedure, both esters are found to be inferior to mineral oil in terms of lightning impulse property and PD behaviour.

14 January 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
SZSicheng Zhao
Sicheng Zhao
QLQiang Liu
Qiang Liu
MWMark Wilkinson
Mark Wilkinson
GWGordon Wilson
Gordon Wilson
ZWZhongdong Wang
Zhongdong Wang
In this paper, a reduced computational fluid dynamics (CFD) model is proposed for determining the total heat dissipation and the oil temperature distribution of transformer radiators in oil natural air natural (ONAN) cooling mode. In the reduced radiator CFD model, the air flow simulation is replaced with an optimized air heat transfer coefficient (h_air) equation. An experimentally verified full radiator CFD model, which includes the air flow simulation, has been introduced as a benchmark model for evaluating the validity of the reduced model. It was found that one h_air can provide sufficient accuracy in simulating the air convection effect of transformer radiators. An h_air equation was derived through a parametric study using the full radiator CFD model. The performance of the proposed h_air equation was compared with the existing empirical equations, and its validities for different insulating liquids and different ambient temperatures were proven by additional CFD modelling. This h_air equation can be transformed into a dimensionless form to help the radiator design and facilitate the complete-cooling-loop (CCL) based transformer CFD modelling.

1 July 2014 in Corrosion Science
Verified
Journal Article
Closed access
MFMarco Facciotti
Marco Facciotti
PAPedro S. Amaro
Pedro S. Amaro
AHAlex F. Holt
Alex F. Holt
RBRichard C.D. Brown
Richard C.D. Brown
PLPaul Lewin
Paul Lewin
PJPaul N. Jarman
Paul N. Jarman

1 October 2013
Verified
Conference Paper
Closed access
SMShekhar Mahmud
Shekhar Mahmud
GCGeorge Chen
George Chen
IGIgor O. Golosnoy
Igor O. Golosnoy
GWGordon Wilson
Gordon Wilson
PJPaul Jarman
Paul Jarman
Cellulose particle accumulation under AC, DC and DC biased AC electric field in transformer oil has been investigated in this paper. Different levels of particle concentrations tested with spherical electrode system. Optical microscopic images and conduction current of the particle accumulation process have been recorded during the experiments. A complete bridge of cellulose particles only observed under DC and DC biased AC electric field.