26 May 2020 in IEEE Sensors Journal
The demand for cable diagnostics and monitoring techniques has increased significantly in recent decades. Various diagnostic tests such as partial discharge, dielectric loss, and elongation-at-break tests are available in real-world applications. Among the cable diagnostic methods, reflectometry can be used to detect the location of a fault according to the reflected signal at the impedance-discontinuity point. Because it is a nondestructive method and can be applied regardless of the cable type, reflectometry is commonly used for monitoring real-world applications. Time–frequency domain reflectometry, an improved type of reflectometry, is more accurate than conventional reflectometry and employs time–frequency localized signals that are robust to noise. To compensate for the errors occurring in the time–frequency domain reflectometry, several algorithms have been reviewed. In the past, because the signal of time-frequency domain reflectometry contains both time and frequency information, a high-specification signal generator and measurement sensors were required, which made practical application of the method difficult. However, with recent developments in instrumentation and sensing technology, reduction in the instrumentation size and cost facilitates the use of time–frequency domain reflectometry in various industrial applications, e.g., control and instrumentation cables in nuclear power plants, superconducting cables, and submarine cables. This work reviews the use of time-frequency domain reflectometry for cable diagnostics and monitoring in real-world applications. The purpose and results of the experiments on industrial applications are introduced and analyzed. This study also suggests directions for further research to make time–frequency domain reflectometry a diagnostic standard.
7 June 2019 in IEEE Transactions on Industrial Electronics
Owing to the increasing complexity of electrical systems, diagnostic techniques of cables used for connecting electrical elements are essential for system maintenance in order to prevent a failure that can cause significant impacts on overall electrical systems. Multicore structures are typically used as control and instrumentation (C&I) cables in nuclear power plants, and the failure of the C&I cables can result in a disaster. In this paper, a method for the diagnosis of multi-core cables is proposed based on reflectometry. The diagnosis relates to the classification of defective cores in joint, which is one of the weakest parts in cable systems. The reflected signals obtained through reflectometry are converted into images by an advanced image processing algorithm, and the images are classified using artificial neural networks. The proposed method is demonstrated by experimental data using a real-world multi-core cable. In the experiment, the faults are emulated similar to real-world defects using a potentiometer. It is expected that the proposed technique will enhance the stability and reliability of multi-core cable systems.
28 January 2021 in IEEE Transactions on Instrumentation and Measurement
In order to improve the performance of the conventional guided wave testing (GWT) with a low sensitivity on damage in pipelines, a new GWT based on time-frequency-domain reflectometry (TFDR) is proposed. TFDR using electromagnetic signals is a diagnostic technique for electrical cables, and the signal is analyzed in both time and frequency domains to enhance the resolution of faults in the electrical cables. Since it is impossible to directly apply the TFDR methodology for electrical cables to the pipelines, this article presents new TFDR methodologies suitable for the ultrasonic characteristics of the pipelines. The proposed technique is demonstrated by experiments using a real-world pipeline. The analysis of the experimental results depending on the changes in the defect size and internal material of the pipeline is provided, and the performance of the proposed technique is confirmed by the experiments.
22 November 2018 in IEEE Transactions on Industrial Electronics
In this paper, new time-frequency-based anomaly detection methodology is proposed for the condition monitoring of high-temperature superconducting (HTS) cable systems. The time-frequency-based anomaly detection methodology includes two indices, which are obtained via cross Wigner-Ville distribution and scattering parameter. For the validation of the proposed methodology, the methodology is applied to an ac 22.9-kV/50-MVA HTS cable system connected to the real power grid network. Furthermore, the changes in dielectric properties of the HTS cable system during the cooling process and the current imbalance failure are monitored. The proposed anomaly detection indices are shown to be able to detect the heat and the current imbalance caused by the malfunction of the joint box. For the application of the two validated indices, new anomaly detection procedure for HTS cable systems is also presented.
4 August 2020 in IEEE Access
High-temperature superconducting (HTS) cables are expected to be installed in cable tunnels that are already constructed in urban districts. Therefore, the installation of normal joint boxes is inevitable, and it is necessary to develop a diagnostic methodology that considers both the existence of the joints and the electrical characteristics of HTS cables. In this work, temporal sliding long short-term memory (TS-LSTM) is proposed to estimate the locations of the joints that can be hidden by multiple reflections. TS-LSTM includes short-term TS-LSTM and long-term TS-LSTM for analyzing various time dependencies. The reflected signals of the actual joints, which are distinguished from multiple reflections, are analyzed via the chirplet transform (CT) which is one of the time-frequency (TF) analysis methods. The proposed condition monitoring method is applied to an AC 154 kV 600 MVA HTS cable system (1 km) connected to a real power grid network in Jeju, South Korea. For the validation of the proposed methodology, the dielectric and electrical characteristics of the 154 kV HTS cable system are monitored during the cooling process.
15 May 2023 in IEEE Transactions on Industrial Electronics
Advanced reflectometry, which can be used to estimate the location of defects in electrical cables with high accuracy, has undergone continuous development based on advanced signal processing techniques. However, in actual fields, nonexperts find it difficult to use advanced reflectometry owing to the difficulty of the application process. Therefore, in this article, a novel technique that can automate the signal-design process in reflectometry, enabling anyone to use advanced reflectometry in the actual field, is proposed. In this work, the signal-design process is automated by utilizing reinforcement learning (RL), and the application methodology is explained using time-frequency domain reflectometry. The agent of the proposed RL model is trained in a simulation-based environment. Finally, the trained agent is applied to a real-world cable to demonstrate its performance.