Emidio Nigro

Emidio Nigro

Auto-generated profile, based on publicly available information

Emidio Nigro

University of Naples “Federico II

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2011 in Journal of Composites for Construction
Verified
Journal Article
Closed access
ABAntonio Bilotta
Antonio Bilotta
FCFrancesca Ceroni
Francesca Ceroni
Marco Di LudovicoMarco Di Ludovico
Marco Di Ludovico
ENE. Nigro
E. Nigro
MPMaria Rosaria Pecce
Maria Rosaria Pecce
GMG. Manfredi
G. Manfredi
This paper reports the results of an experimental program to investigate the bonding behavior of two different types of fiber-reinforced polymer (FRP) systems for strengthening RC members: externally bonded carbon (EBR) plates and bars or strips externally applied with the near-surface-mounted (NSM) technique. The overall experimental program consisted of 18 bond tests on concrete specimens strengthened with EBR carbon plates and 24 bond tests on concrete specimens strengthened with NSM systems (carbon, basalt, and glass bars, and carbon strips). Single shear tests (SST) were carried out on concrete prisms with low compressive strengths to investigate the bonding behavior of existing RC structures strengthened with different types of FRP systems. The performance of each reinforcement system is presented, discussed, and compared in terms of failure mode, debonding load, load-slip relationship, and strain distribution. The findings indicate that the NSM technique could represent a sound alternative to EBR systems because it allows debonding to be delayed, and hence FRP tensile strength to be better exploited.

1 August 2012 in Journal of Composites for Construction
Verified
Journal Article
Closed access
ENEmidio Nigro
Emidio Nigro
ABAntonio Bilotta
Antonio Bilotta
GCGiuseppe Cefarelli
Giuseppe Cefarelli
GMGaetano Manfredi
Gaetano Manfredi
ECEdoardo Cosenza
Edoardo Cosenza
Intuitively, the fire endurance of concrete members reinforced with fiber reinforced polymer (FRP) bars is related to the decrease in the mechanical properties of the materials concerned, especially resin. Large-scale fire tests recently performed on nine concrete slabs reinforced with glass FRP bars demonstrated the importance of bond between FRP and concrete for performance under fire situations. The experimental results showed that (1) the length of the FRP bars in the zone of slabs not directly exposed to fire (namely, anchoring length in fire situations) can be much more relevant to fire endurance than the concrete cover in the zone directly exposed to fire; and (2) the shape of the bar, for instance bent at the end, allows a reduction in anchoring length. From a design point of view, evaluating the necessary anchoring length through a bond model seems to be a key aspect. Full-scale test results, extensively presented elsewhere, are used in this paper to investigate the bond behavior of FRP bars embedded in concrete at high temperature and to assess a procedure to predict bond stress, slip, and load transfer at elevated temperature, based on both the results of numerical thermal analysis and the predictions of a bond theoretical model adjusted for fire situations. The design procedure outlined for calculating the minimal required anchoring length proves a valuable approach for the practicing engineer and stands together with the experimental and numerical results presented earlier. Finally, design nomograms are shown as examples of application of the procedure.

1 February 2016 in Journal of Composites for Construction
Verified
Journal Article
Closed access
ABAntonio Bilotta
Antonio Bilotta
FCFrancesca Ceroni
Francesca Ceroni
JBJoaquim António Oliveira de Barros
Joaquim António Oliveira de Barros
ICInês Costa
Inês Costa
APAniello Palmieri
Aniello Palmieri
MPMaria Rosaria Pecce
Maria Rosaria Pecce
Despite the extensive research on the debonding behavior of fiber-reinforced polymer (FRP) strengthening systems, no standard methodology has been established on its experimental characterization. To assess the performance and reliability of small-scale testing on near-surface mounted (NSM) FRP strengthening systems, an experimental program was carried out on a series of nine NSM FRP strengthening systems (bars and strips), in the framework of an international round robin testing (RRT). Eleven laboratories and seven manufacturers and suppliers participated in this extensive international exercise, which regarded both NSM and EBR FRP strengthening systems. The experimental results are discussed and compared in this paper in order to investigate (1) the bond behavior of NSM strips and bars, (2) the influence of alternative single-bond or double-bond shear pulling setups adopted by the participating laboratories, and (3) the influence in concrete strength due to different constituent materials between countries in applying a prescribed mix. The results show no significant influence of the concrete strength on both failure modes and loads. On the other hand, axial stiffness and surface treatment of the FRP NSM systems strongly affect both the bond strength and the parameters identifying the bond laws. Differences of bond strength experimentally recorded for the same FRP NSM systems tested according to different setups range between 10 and 25%. Therefore, for standard bond test protocol, the single shear bond test setup is more reliable, due to its higher feasibility compared with the double shear test setup.

19 May 2022 in Coatings
Verified
Journal Article
Open access
PDF file
Donatella de SilvaDonatella de Silva
Donatella de Silva
INIolanda Nuzzo
Iolanda Nuzzo
ENEmidio Nigro
Emidio Nigro
AOAntonio Occhiuzzi
Antonio Occhiuzzi
Intumescent coatings (ICs) are often used for protecting steel buildings during a fire when the structural, aesthetic, and architectural features of the structural members should be preserved. Indeed, ICs form a thin protective layer on the steel surface, that if exposed to fire or elevated temperatures, expands in volume with a consequent reduction in density. Hence, the protective layer captivates heat and protects the structural member from damage or elevated deformation. This reactive fire protection is designed using prescriptive tables, in which the IC thickness is chosen according to the required fire resistance, critical temperature, and section factor of the steel element. These tables are elaborated on the basis of the tests results according to the UNI EN 13381-8 standard, which is the reference for characterizing reactive systems such as ICs. For its reactive nature, this fire protection has to be applied to the structure in a controlled manner, and it is good practice to verify its correct application by measuring thickness and adhesion in situ through regulated methods. The qualification process of IC systems in Italy can be realized through a voluntary certification within the scope of a European technical assessment or by means of a national technical assessment certificate that is mandatory. All these aspects related to qualification, assessment, and design of ICs are often ignored by both designers and manufacturers, especially in Italy. Therefore, this paper describes all the approaches, introducing the main technical differences, in order to provide a sort of guideline on the use of these reactive fire protections.

1 April 2011 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
ENE. Nigro
E. Nigro
Marco Di LudovicoMarco Di Ludovico
Marco Di Ludovico
ABAntonio Bilotta
Antonio Bilotta
The effectiveness of externally bonded fiber-reinforced polymer (FRP) laminates for strengthening existing reinforced concrete (RC) structures is strictly related to the bond of the FRP reinforcement to the concrete substrate. Although numerous experimental studies have investigated this bond, experimental data concerning cyclic tests on both FRP sheets and plates applied on concrete specimens are still lacking. Thus, a series of single shear tests (SSTs) under both monotonic and cyclic actions, without inversion of sign, were performed on concrete prismatic specimens reinforced with carbon FRP (CFRP) sheets or plates. To evaluate and compare the influence of cyclic external actions on the bonding behavior of sheets and plate reinforcements, the results provided by monotonic and cyclic tests are reported and discussed in this paper. In particular, force-displacement relationships, axial strains, and shear stresses recorded along the FRP reinforcement are reported; the influence of the load path on the FRP...

1 April 2012 in Journal of Composites for Construction
Verified
Journal Article
Closed access
ABA. Bilotta
A. Bilotta
CFC. Faella
C. Faella
Enzo MartinelliEnzo Martinelli
Enzo Martinelli
ENE. Nigro
E. Nigro
The mechanical response of Reinforced Concrete (RC) beams strengthened by an Externally Bonded Reinforcement (EBR) made out of Fiber-Reinforced Polymers (FRPs) is deeply influenced by the interaction between the concrete substrate and the FRP system, either cured-in-place (sheets) or preformed (plates). In particular, the strength of FRP-EBR RC beams is often controlled by debonding phenomena to develop at the adhesive-to-concrete interface. The most recent theoretical formulations and some experimental results obtained in the last years pointed out the differences that characterize the debonding strength of FRP sheets and plates. According to the findings of those studies, the fracture energy is a fundamental parameter governing the debonding phenomenon. However, determining its value is not sufficient for simulating the behavior of the FRP-to-concrete interface and modeling relevant problems such as intermediate debonding in RC beams externally strengthened by FRP. Consequently, formulating and ...