1 April 2017 in Engineering Science and Technology, an International Journal
A Modified Grey Wolf Optimization (MGWO) based cascade PI-PD controller is suggested in this paper for Automatic Generation Control (AGC) of power systems in presence of Plug in Electric Vehicles (PEV). The modification in original Grey Wolf Optimization (GWO) algorithm is introduced by strategy which maintains a proper balance between exploration and exploitation stages of the algorithm and gives more importance to the fittest wolves to find the new position of grey wolves during the iterations. Proposed algorithm is first tested using four bench mark test functions and compared with original GWO, Differential Evolution (DE), Gravitational Search Algorithm (GSA), Particle Swarm Optimization (PSO) to show its superiority. The proposed technique is then used to tune various conventional controllers in a single area three-unit power system consisting of thermal hydro and gas power plants for AGC. The superiority of proposed MGWO algorithm over some recently proposed approaches has been demonstrated. In the next step, different controllers like PI, PID, and cascaded PI-PD controller are taken and Plug in Electric Vehicles (PEVs) are assumed. The proposed approach is also extended to a two-area six-unit power system. Lastly, a five unequal area nonlinear power system with PEVs and dissimilar cascade PI-PD controller in each area is considered and proposed MGWO technique is employed to optimize the controller parameters in presence of nonlinearities like rate constraint of units, dead zone of governor and communication delay. It is observed that PEVs contribute in the AGC to control system frequency
26 February 2018 in Arabian Journal for Science and Engineering
7 May 2018 in International Journal of Numerical Modelling: Electronic Networks, Devices and Fields
27 May 2022 in IET Renewable Power Generation
Renewable generation uncertainty, dynamic load change, and system parameter variation play a significant role in the performance degradation of non‐linear multi‐microgrid (MMG) systems. As a result, intelligent control becomes the need of the hour for assisting superlative attribute‐ based consistent electric power. The application of marine predator algorithm (MPA)‐based cascaded PD‐(1+PI) controller for Automatic Generation Control (AGC) of MMG system is a novel work. A maiden attempt of the MPA is proposed to optimize the parameters of the cascaded PD‐(1+PI) controller using the integral time absolute error criterion. To demonstrate its superiority, the proposed algorithm is compared to the genetic algorithm, differential evolution, and grey wolf optimization. MPA then applied to conventional controller PID, cascaded PD‐PI controller and proposed PD‐(1+PI) controller for frequency control in multi‐microgrid system. The robustness of the suggested controller is verified over PID and PD‐PI controller by taking step and random load perturbation and integrating the renewable sources like solar and wind with their uncertain nature. The simulation of the investigated interconnected microgrid is carried out in MATLAB/SIMULINK environment. Finally, detailed simulation and hardware in the loop experimental results are presented to confirm the practicality of the proposed approach.
8 May 2025 in Electric Power Systems Research
RKRajendra Kumar Khadanga