Ashwini Kumar Mishra

Ashwini Kumar Mishra

Auto-generated profile, based on publicly available information

Ashwini Kumar Mishra

Department of Electronics Engineering, Indian Institute of Technology (BHU), Varanasi-221005, India

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
AMAshwini Kumar Mishra
Ashwini Kumar Mishra
DJDeepak Kumar Jarwal
Deepak Kumar Jarwal
BMBratindranath Mukherjee
Bratindranath Mukherjee
AKAmit Kumar
Amit Kumar
SRSmrity Ratan
Smrity Ratan
Satyabrata JitSatyabrata Jit
Satyabrata Jit

14 January 2019 in RSC Advances
Verified
Journal Article
Open access
PDF file
AMAshwini Kumar Mishra
Ashwini Kumar Mishra
BMBratindranath Mukherjee
Bratindranath Mukherjee
AKAmit Kumar
Amit Kumar
DJDeepak Kumar Jarwal
Deepak Kumar Jarwal
SRSmrity Ratan
Smrity Ratan
Satyabrata JitSatyabrata Jit
Satyabrata Jit
This paper describes a low-cost facile method to construct gold (Au) nanoparticles (NPs) modified copper oxide (CuO) nanowires (NWs) electrode on copper foil for the detection of glucose. Copper foil has been converted to aligned CuO NWs arrays by sequential formation of Cu(OH)2 followed by heat treatment induced phase transformation to CuO. Au NPs are deposited on CuO NWs via simple reductive solution chemistry to impart high surface to volume ratio and enhanced catalytic activity of the resulting electrode. Structure, microstructure and morphology of Cu, Cu(OH)2 NWs, CuO NWs, and Au NPs modified CuO NWs are investigated by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The homogeneous distribution of Au NPs (average diameter ∼12 nm) on CuO NWs (average diameter 100 nm and aspect ratio ∼20) is confirmed by high-resolution transmission electron microscopy (HRTEM), scanning transmission electron microscopy (STEM) and elemental mapping. This CuO based glucose detection method gives the highest sensitivity along with the maximum linearity range. This non-enzymatic glucose sensor based on Au modified CuO NWs electrode gives broad linearity range from 0.5 μM to 5.9 mM. The sensor exhibits sensitivity of 4398.8 μA mM−1 cm−2, lower detection limit of 0.5 μM, and very fast response time of ∼5 s. Properties of the proposed glucose sensor are also investigated in human blood and it is found that the sensor is highly accurate and reliable. In addition, higher sensitivity and lower detection limit confirm that this device is suitable for invasive detection in saliva and urine.