Kayla O'Sullivan-Steben

Kayla O'Sullivan-Steben

Auto-generated profile, based on publicly available information

Kayla O'Sullivan-Steben

Medical Physics Unit McGill University Montreal QC Canada

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
KOKayla O'SUllivan‐Steben
Kayla O'SUllivan‐Steben
LGLuc Galarneau
Luc Galarneau
SJSusie Judd
Susie Judd
ALAndrea M. Laizner
Andrea M. Laizner
TWTristan Williams
Tristan Williams
JKJohn Kildea
John Kildea
Purpose: Radiotherapy patients often face undue anxiety due to misconceptions about radiation and their inability to visualize their upcoming treatments. Access to their personal treatment plans is one way in which pre‐treatment anxiety may be reduced. But radiotherapy data are quite complex, requiring specialized software for display and necessitating personalized explanations for patients to understand them. Therefore, our goal was to design and implement a novel radiotherapy menu in a patient portal to improve patient access to and understanding of their radiotherapy treatment plans.Methods: A prototype radiotherapy menu was developed in our institution's patient portal following a participatory stakeholder co‐design methodology. Customizable page templates were designed to render key radiotherapy data in the portal's patient‐facing mobile phone app. DICOM‐RT data were used to provide patients with relevant treatment parameters and generate pre‐treatment 3D visualizations of planned treatment beams, while the mCODE data standard was used to provide post‐treatment summaries of the delivered treatments. A focus group was conducted to gather initial patient feedback on the menu.Results: Pre‐treatment: the radiotherapy menu provides patients with a personalized treatment plan overview, including a personalized explanation of their treatment, along with an interactive 3D rendering of their body, and treatment beams for visualization. Post‐treatment: a summary of the delivered radiotherapy is provided, allowing patients to retain a concise personal record of their treatment that can easily be shared with future healthcare providers. Focus group feedback was overwhelmingly positive. Patients highlighted how the intuitive presentation of their complex radiotherapy data would better prepare them for their radiation treatments.Conclusions: We successfully designed and implemented a prototype radiotherapy menu in our institution's patient portal that improves patient access to and understanding of their radiotherapy data. We used the mCODE data standard to generate post‐treatment summaries in a way that is easily shareable and interoperable.

26 November 2025 in Medical Physics
Verified
Journal Article
Open access
KOKayla O'SUllivan‐Steben
Kayla O'SUllivan‐Steben
LGLuc Galarneau
Luc Galarneau
JKJohn Kildea
John Kildea
Background: The increase in public medical imaging datasets has raised concerns about potential patient reidentification from head CT scans. However, existing defacing algorithms, which help protect patient confidentiality, fail to preserve critical radiotherapy structures, including organs at risk (OARs) and planning target volumes (PTVs) in head and neck cancer (HNC) patients. Furthermore, current algorithms do not address the defacing of DICOM‐RT structure set and dose data, which also contain information for facial surface rendering. Purpose: To develop and validate a novel automated defacing algorithm that preserves OARs and PTVs while removing identifiable features from HNC CTs and DICOM‐RT data. Methods: Eye contours were used as landmarks to automate the removal of CT pixels above the inferior‐most slice of the eye and anterior to the midpoint of the eye. Pixels within PTVs were retained if they intersected with the removed region. The body contour and dose map were then reshaped to reflect the defaced image. We validated our approach on 829 HNC CT‐simulation scans from 622 patients. To evaluate privacy protection, we applied the FaceNet512 facial recognition algorithm before and after defacing on 3D‐rendered CT scan pairs from 70 patients at two time points. To assess research utility, we examined the impact of defacing on auto‐contouring performance using LimbusAI and analyzed the locations of PTVs relative to the defaced regions. Results: Before defacing, the facial recognition algorithm matched 97% of patients' CT scans. After defacing, this rate dropped to just 4%. LimbusAI effectively auto‐contoured organs in the defaced CTs, with perfect Dice scores of 1 for OARs below the defaced region, and mean Dice scores exceeding 0.95 for OARs on the same slices as the defaced region. PTV analysis revealed that 86% of PTVs were entirely below the cropped region, 9.1% were on the same slice as the crop without overlap, and only 4.9% extended into the cropped area. All overlapping PTVs were preserved through our algorithm's design. Conclusions: We developed a novel defacing algorithm that anonymizes HNC CT scans and related DICOM‐RT data. Our algorithm balances patient privacy while preserving essential structures for radiotherapy research, facilitating the sharing of HNC imaging datasets for Big Data and AI.

19 August 2025 in arXiv
Verified
Preprint
Open access
PDF file
KOKayla O'Sullivan-Steben
Kayla O'Sullivan-Steben
LGLuc Galarneau
Luc Galarneau
JKJohn Kildea
John Kildea
Introduction: The rise in public medical imaging datasets has raised concerns about patient reidentification from head CT scans. However, existing defacing algorithms often remove or distort Organs at Risk (OARs) and Planning Target Volumes (PTVs) in head and neck cancer (HNC) patients, and ignore DICOM-RT Structure Set and Dose data. Therefore, we developed and validated a novel automated defacing algorithm that preserves these critical structures while removing identifiable features from HNC CTs and DICOM-RT data. Methods: Eye contours were used as landmarks to automate the removal of CT pixels above the inferior-most eye slice and anterior to the eye midpoint. Pixels within PTVs were retained if they intersected with the removed region. The body contour and dose map were reshaped to reflect the defaced image. We validated our approach on 829 HNC CTs from 622 patients. Privacy protection was evaluated by applying the FaceNet512 facial recognition algorithm before and after defacing on 3D-rendered CT pairs from 70 patients. Research utility was assessed by examining the impact of defacing on autocontouring performance using LimbusAI and analyzing PTV locations relative to the defaced regions. Results: Before defacing, FaceNet512 matched 97% of patients' CTs. After defacing, this rate dropped to 4%. LimbusAI effectively autocontoured organs in the defaced CTs, with perfect Dice scores of 1 for OARs below the defaced region, and excellent scores exceeding 0.95 for OARs on the same slices as the crop. We found that 86% of PTVs were entirely below the cropped region, 9.1% were on the same slice as the crop without overlap, and only 4.9% extended into the cropped area. Conclusions: We developed a novel defacing algorithm that anonymizes HNC CT scans and related DICOM-RT data while preserving essential structures, enabling the sharing of HNC imaging datasets for Big Data and AI.

17 January 2026 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
OROdette Rios-Ibacache
Odette Rios-Ibacache
JMJames Manalad
James Manalad
KOKayla O'SUllivan‐Steben
Kayla O'SUllivan‐Steben
EPEmily Poon
Emily Poon
LGLuc Galarneau
Luc Galarneau
JKJohn Kildea
John Kildea
Background: Head and neck cancer (HNC) patients undergoing radiotherapy (RT) may experience anatomical changes during treatment, which can compromise the validity of the initial treatment plan, necessitating replanning. However, ad hoc replanning disrupts clinical workflows and increases workload. Currently, no standardized method exists to quantify anatomical variation that necessitates replanning. Purpose: This project aimed to create geometrical metrics to describe anatomical changes in HNC patients during RT. The usefulness of these metrics was evaluated by a univariate analysis and through machine learning (ML) models to predict the need for replanning. Methods: A cohort of 150 HNC patients treated at McGill University Health Centre was analyzed. Based on the shapes of the RT structures (body, PTV, mandible, neck, and submandibular contours), we developed 43 metrics and automatically calculated them through a Python pipeline that we called HNGeoNatomyX . Univariate analysis using linear regression was conducted to obtain the rate of change of each metric. We also obtained the relative variation of each metric between the pre‐treatment and replanning‐requested scans. Fraction‐specific ML models (incorporating information available up to and including the specific fraction) for fractions 5, 10, and 15 were built using metrics, clinical data, and feature selection techniques. Model performance was estimated with repeated stratified 5‐fold cross‐validation resampling technique and the area under the curve (AUC) of the receiver operating characteristic (ROC) curve. Results: Univariate analysis showed that body‐ and neck‐related metrics were most predictive of replanning need. Our best specific multivariate models for fractions 5, 10, and 15 yielded testing scores of 0.82, 0.70, and 0.79, respectively. Our models early predicted replanning for 76% of the true positives. Conclusions: The created metrics have the potential to characterize and distinguish which patients will necessitate RT replanning. They show promise in guiding clinicians to evaluate RT replanning for HNC patients and streamline workflows.