18 May 2021 in Applied Physics Reviews
Antibiotic-resistant bacteria, which are growing at a frightening rate worldwide, has put the world on a long-standing alert. The COVID-19 health crisis reinforced the pressing need to address a fast-developing pandemic. To mitigate these health emergencies and prevent economic collapse, cheap, practical, and easily applicable infection control techniques are essential worldwide. Application of light in the form of photodynamic action on microorganisms and viruses has been growing and is now successfully applied in several areas. The efficacy of this approach has been demonstrated in the fight against viruses, prompting additional efforts to advance the technique, including safety use protocols. In particular, its application to suppress respiratory tract infections and to provide decontamination of fluids, such as blood plasma and others, can become an inexpensive alternative strategy in the fight against viral and bacterial infections. Diverse early treatment methods based on photodynamic action enable an accelerated response to emerging threats prior to the availability of preventative drugs. In this review, we evaluate a vast number of photodynamic demonstrations and first-principle proofs carried out on viral control, revealing its potential and encouraging its rapid development toward safe clinical practice. This review highlights the main research trends and, as a futuristic exercise, anticipates potential situations where photodynamic treatment can provide a readily available solution.
21 January 2026 in NeuroImage
Recent neurosurgery advancements include improved stereotactic targeting and increased density and specificity of electrophysiological evaluation. This study introduces a subject-specific, in silico modeling tool for optimizing electrode placement and maximizing coverage with a variety of devices. The basis for optimization is the Shannon-Hartley information capacity of field potentials derived from dipolar sources. The approach integrates subject-specific MRI data with finite element modeling (FEM) used to simulate the sensitivity of subdural and intracortical devices. Sensitivity maps, or lead fields, from these models enable the comparison of different electrode placements, contact sizes, contact configurations, and substrate properties, which are often overlooked factors. One key tool is a genetic algorithm that optimizes electrode placement by maximizing information capacity. Another is a sparse sensor method, Sparse Electrode Placement for Input Optimization (SEPIO), that selects the best sensor subsets for accurate source classification. We demonstrate several use cases for clinicians, engineers, and researchers. Overall, these open-source tools provide a quantitative framework to select devices from a neurosurgical armament and to optimize device and contact placement. Using these tools may help refine electrode coverage with low channel count devices while minimizing the burden of invasive surgery. The study demonstrates that optimized electrode placement significantly improves the information capacity and signal quality of local field potential (LFP) recordings. The tools developed offer a valuable approach for refining neurosurgical techniques and enhancing the design of neural implants.
23 September 2026 in bioRxiv
Extracellular electrophysiological recordings reflect both the organization of neural activity and the geometry through which that activity is sampled. Here, we used biophysical modeling and experimental recordings from the macaque auditory cortex to determine how cortical activity is transformed across neural sources, extracellular signals, and recording geometries. In a biophysically detailed thalamocortical model, four separately instantiated cortical-column conditions spanning graded thalamic recruitment exhibited a graded response hierarchy across local field potential, current-source density, and multiunit activity, despite signal-dependent differences in the contributions of cortical neuronal populations. We then arranged independently simulated cortical columns into controlled spatial configurations and sampled the same underlying sources using virtual linear laminar and Directional and Scalable (DiSc) electrode arrays. The linear geometry primarily represented variation along cortical depth, whereas DiSc additionally represented circumferential variation associated with lateral source organization, demonstrating that recording geometry determines which spatial dimensions of common underlying activity are represented in extracellular measurements. Experimental recordings obtained with the corresponding geometries were consistent with these model-derived predictions: broadband-noise responses exhibited spatial organization shared across tone-evoked responses in both multidimensional DiSc maps and laminar profiles, despite substantial variation in frequency-dependent response magnitude across penetrations. Together, these results show that extracellular measurements represent an interaction between biological source organization and recording geometry. Biophysical forward modeling therefore provides a framework for determining which features of underlying circuit organization remain identifiable after extracellular sampling and for relating neural-interface design to the dimensions of cortical activity accessible experimentally.