Changzhi Peng

Changzhi Peng

Auto-generated profile, based on publicly available information

Changzhi Peng

State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2022 in High Voltage
Verified
Journal Article
Open access
CPChangzhi Peng
Changzhi Peng
XDXuzhu Dong
Xuzhu Dong
YZYanpu Zhao
Yanpu Zhao
ZLZhijun Li
Zhijun Li
YZYu Zheng
Yu Zheng
BLBing Luo
Bing Luo
The physical mechanism of leader formation and development is not well understood. In this study, we present experimental and simulation results obtained with a 10 m long air gap discharge. A 10 m outdoor discharge experiment is carried out to obtain the current, voltage, and optical image during the leader discharge process. Four different impulse voltages were applied to the rod‐plane gap. The measured current is used as an input for a plasma model, then the temperature and electric field could be calculated. The simulation results show that the temperature of the streamer stem during the dark period may exceed 2000 K. In addition, the critical charge required for leader initiation can be as low as 0.27 μC for a 10 m air gap. The channel temperature is relatively stable in the process of leader development, which is maintained at about 4500 K. The electron density is about 0.5–3 × 10 20 m −3 , and the discharge channel conductivity fluctuates in the range of 1–10 S/m for the leader current between 1 and 2 A. A long dark period is tended to be associated with a higher injected charge by the first streamer. It is inferred that the voltage increments during the dark period play an important role in promoting streamer‐to‐leader transition, except for temperature and the injected charge.

14 August 2023 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
CPChangzhi Peng
Changzhi Peng
RSRuth V. Sabariego
Ruth V. Sabariego
XDXuzhu Dong
Xuzhu Dong
JRJiangjun Ruan
Jiangjun Ruan
The streamer discharge physical process can be described by the coupled Poisson’s equation and the convection diffusion equation. It is a multi-physical field problem involving electromagnetism and hydrodynamics. We propose a streamer discharge model based on physics-informed neural networks (PINN) to improve the computational efficiency regarding the classical approach. The Poisson’s equation and the convection-diffusion equation are trained to generate sufficient data and construct a deep operator neural network (DeepONet). The performance of the PINN, in terms of accuracy, is analyzed by applying it to different datasets (electron density and potential distribution) and comparing to a reference solution (spatial evolution of electrons). The simulation results show that the neural network has high accuracy in learning two types of equations.

8 June 2024 in Geophysical Research Letters
Verified
Journal Article
Open access
CPChangzhi Peng
Changzhi Peng
ZLZhijun Li
Zhijun Li
XPXuekai Pei
Xuekai Pei
XZXiangen Zhao
Xiangen Zhao
GLGaopeng Lu
Gaopeng Lu
XDXuzhu Dong
Xuzhu Dong
Positive leaders branch less frequently than negative counterpart, and the physical processes and properties of positive leader branching remain a mystery. We investigated 10 m laboratory discharges under four positive voltages using a high‐speed video camera. Positive leaders differ from negative leaders by either directly splitting or connecting with floating bidirectional leaders to form branching, and the number of leader branches shows a positive correlation with the applied voltage, that is, the branched channels increased from 1 to 4 when the voltage increased by a factor of 1.5. Grounding points are positioned beneath the electrode and are more concentrated with lower voltage. During the stable progression of the leader, there is a slight increase in its development speed as the applied voltage rises. When the voltage is increased by 70%, the average breakdown time decreases by 40%. These characteristics provide insights into the branching mechanism of positive leaders.

18 April 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
CPChangzhi Peng
Changzhi Peng
XDXuzhu Dong
Xuzhu Dong
RSRuth V. Sabariego
Ruth V. Sabariego
YZYu Zheng
Yu Zheng
YDYongqing Deng
Yongqing Deng
PXPengkang Xie
Pengkang Xie
Long air gap discharge is one of the fundamental issues in high voltage engineering. The simulation of long air gap discharge can provide essential data for designing ultra-high voltage transmission and serves as the foundation for lightning protection. This study introduces an enhanced numerical model for simulating long air gap discharge, accounting for time-varying leader charge density and streamer region with direct experimental extraction. The comprehensive three-dimensional (3-D) model integrates novel parameters, including the streamer region angle, direction, and stochastic leader development, surpassing mere empirical descriptions. Additionally, the updated methodology for determining the streamer region makes the model adaptable to symmetric and asymmetric geometric engineering structures. Simplifying assumptions render the model computationally lightweight in full 3-D demand. The model simulated the current, velocity, and leader path of long air gap discharge under various voltages, then compared with experimental results. By incorporating new physical quantities, the model exhibited improved accuracy and precisely predicted current and velocity. Furthermore, the model calculated the breakdown voltage of typical engineering gaps, yielding results closely aligned with experimental data, with an accuracy exceeding 90%.

31 October 2025 in IEEE Open Journal of Industry Applications
Verified
Journal Article
Open access
CPChangzhi Peng
Changzhi Peng
LXLiang Xie
Liang Xie
XPXuekai Pei
Xuekai Pei
XDXuzhu Dong
Xuzhu Dong
PXPengkang Xie
Pengkang Xie
With the rise of the carbon neutrality strategy, there has been a global push to harness clean energy sources such as solar, wind, and hydropower, which are often located in remote areas from central cities. Long-distance transmission lines traverse various complex terrains, potentially crossing regions in China with altitudes ranging from 0 to 4800 m. In this context, this paper focuses on studying the corona inception characteristics of large transmission line fittings at different altitudes. Firstly, the corona characteristics of transmission line fittings at altitudes of 60 m and 4350 m are examined. The study obtained corona inception electric field characteristics for fittings with different type and size. Additionally, to understand the corona inception characteristics of fittings at intermediate altitudes, simulated altitude tests were conducted in an artificial climate laboratory. Based on these experimental results, this study provides recommended fitting parameters for transmission lines at various altitudes. Furthermore, considering that transmission towers, especially tension towers with special conductor structures, may exhibit increased corona characteristics due to conductor bending, the impact of jump lines on corona discharge characteristics in high altitude areas was also investigated. The series of conductor parameters obtained will benefit the construction of transmission lines in various regions globally.

15 September 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LCLi Cai
Li Cai
HJHaohao Jin
Haohao Jin
CPChangzhi Peng
Changzhi Peng
MCMengyuan Chen
Mengyuan Chen
JWJianguo Wang
Jianguo Wang
XDXuzhu Dong
Xuzhu Dong
Variations in air pressure, temperature, and humidity at high altitudes affect the discharge characteristics of long air gaps and the variability of discharge channel tortuosity. The degree of zigzagging was believed to influence the breakdown voltage and discharge path of the gap; however, there was a lack of relevant experimental and research support. In this study, the effect of the high-altitude environment on the tortuosity of the long air gap discharge path was investigated. The experiments were conducted in Tibet at an altitude of 4650 m. The discharge voltages, currents, and optical frames of different types of electrodes (rod, sphere, and corona ring plane) were investigated for different gap lengths. The results showed that both the deviation angle Φ and the bending angle $\beta $ followed a normal distribution. Both gap distance and electrode type affected the degree of tortuosity. The study also identified a three-phase development pattern in the discharge channel through K-means clustering analysis. At an altitude of 4650 m, the average deflection angle was 12.7° with a standard deviation of ±10.0°. At higher altitudes, the data were more dispersed with a wider probability density curve, while at lower altitudes, the curve was more concentrated. The findings of this study provided valuable data for air discharge simulation and high voltage engineering projects under high altitude environments.