Sajad Mohammed Ali

Sajad Mohammed Ali

Auto-generated profile, based on publicly available information

Sajad Mohammed Ali

Department of Medical Radiation Physics Lund University Lund Sweden

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SASajad Mohammed Ali
Sajad Mohammed Ali
NYNirbhay Yadav
Nirbhay Yadav
RWRonnie Wirestam
Ronnie Wirestam
MSMunendra Singh
Munendra Singh
HHHye‐Young Heo
Hye‐Young Heo
LKLinda Knutsson
Linda Knutsson
Purpose: Water saturation shift referencing (WASSR) Z‐spectra are used commonly for field referencing in chemical exchange saturation transfer (CEST) MRI. However, their analysis using least‐squares (LS) Lorentzian fitting is time‐consuming and prone to errors because of the unavoidable noise in vivo. A deep learning–based single Lorentzian Fitting Network (sLoFNet) is proposed to overcome these shortcomings.Methods: A neural network architecture was constructed and its hyperparameters optimized. Training was conducted on a simulated and in vivo–paired data sets of discrete signal values and their corresponding Lorentzian shape parameters. The sLoFNet performance was compared with LS on several WASSR data sets (both simulated and in vivo 3T brain scans). Prediction errors, robustness against noise, effects of sampling density, and time consumption were compared.Results: LS and sLoFNet performed comparably in terms of RMS error and mean absolute error on all in vivo data with no statistically significant difference. Although the LS method fitted well on samples with low noise, its error increased rapidly when increasing sample noise up to 4.5%, whereas the error of sLoFNet increased only marginally. With the reduction of Z‐spectral sampling density, prediction errors increased for both methods, but the increase occurred earlier (at 25 vs. 15 frequency points) and was more pronounced for LS. Furthermore, sLoFNet performed, on average, 70 times faster than the LS‐method.Conclusion: Comparisons between LS and sLoFNet on simulated and in vivo WASSR MRI Z‐spectra in terms of robustness against noise and decreased sample resolution, as well as time consumption, showed significant advantages for sLoFNet.

17 March 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
LKLinda Knutsson
Linda Knutsson
NYNirbhay N. Yadav
Nirbhay N. Yadav
SASajad Mohammed Ali
Sajad Mohammed Ali
DKDavid Olayinka Kamson
David Olayinka Kamson
EDEleni Demetriou
Eleni Demetriou
PZPeter C. M. van Zijl
Peter C. M. van Zijl
Purpose: Dynamic glucose enhanced (DGE) MRI studies employ CEST or spin lock (CESL) to study glucose uptake. Currently, these methods are hampered by low effect size and sensitivity to motion. To overcome this, we propose to utilize exchange‐based linewidth (LW) broadening of the direct water saturation (DS) curve of the water saturation spectrum (Z‐spectrum) during and after glucose infusion (DS‐DGE MRI). Methods: To estimate the glucose‐infusion‐induced LW changes ( Δ LW) , Bloch‐McConnell simulations were performed for normoglycemia and hyperglycemia in blood, gray matter (GM), white matter (WM), CSF, and malignant tumor tissue. Whole‐brain DS‐DGE imaging was implemented at 3 T using dynamic Z‐spectral acquisitions (1.2 s per offset frequency, 38 s per spectrum) and assessed on four brain tumor patients using infusion of 35 g of D‐glucose. To assess Δ LW , a deep learning‐based Lorentzian fitting approach was used on voxel‐based DS spectra acquired before, during, and post‐infusion. Area‐under‐the‐curve (AUC) images, obtained from the dynamic Δ LW time curves, were compared qualitatively to perfusion‐weighted imaging parametric maps. Results: In simulations, Δ LW was 1.3%, 0.30%, 0.29/0.34%, 7.5%, and 13% in arterial blood, venous blood, GM/WM, malignant tumor tissue, and CSF, respectively. In vivo, Δ LW was approximately 1% in GM/WM, 5% to 20% for different tumor types, and 40% in CSF. The resulting DS‐DGE AUC maps clearly outlined lesion areas. Conclusions: DS‐DGE MRI is highly promising for assessing D‐glucose uptake. Initial results in brain tumor patients show high‐quality AUC maps of glucose‐induced line broadening and DGE‐based lesion enhancement similar and/or complementary to perfusion‐weighted imaging.

18 February 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SASajad Mohammed Ali
Sajad Mohammed Ali
PZPeter C. M. van Zijl
Peter C. M. van Zijl
JPJannik Prasuhn
Jannik Prasuhn
RWRonnie Wirestam
Ronnie Wirestam
LKLinda Knutsson
Linda Knutsson
NYNirbhay Yadav
Nirbhay Yadav
Purpose: Four‐pool Voigt (FPV) machine learning (ML)–based fitting for Z‐spectra was developed to reduce fitting times for clinical feasibility in terms of on‐scanner analysis and to promote larger cohort studies. The approach was compared to four‐pool Lorentzian (FPL)‐ML–based modeling to empirically verify the advantage of Voigt models for Z‐spectra. Methods: Voigt and Lorentzian models were fitted to human 3 T Z‐spectral data using least squares (LS) to generate training data for the corresponding ML versions. Gradient boosting decision trees were trained, resulting in one Voigt and one Lorentzian ML model. Modeling accuracy was tested, and the fitting times of the ML models and LS versions were evaluated. The goodness of fits of Voigt and Lorentzian ML models were compared. Results: The training time for each ML model (Voigt and Lorentzian) was less than 1 min, and the modeling accuracy compared to the corresponding LS versions was excellent, as indicated by a nonsignificant difference between the parameters obtained by LS and corresponding ML versions. The average fitting time was 20 μs/spectrum for both ML models compared to 0.27 and 0.82 s/spectrum for LS with FPL and FPV, respectively. The goodness of fits of FPV‐ML and FPL‐ML differed significantly ( p < 0.005), with FPV‐ML showing an improvement for all tested data. Conclusion: Gradient boosting decision trees fitting of multi‐pool Z‐spectra significantly reduces fitting times compared to traditional LS approaches, allowing fast data processing while upholding fitting quality. Along with the short training times, this makes the method suitable for clinical settings and for large cohort research applications. The FPV‐ML approach provides a significant improvement of goodness of fit compared to FPL‐ML.

24 April 2025
Verified
Journal Article
Open access
LKLinda Knutsson
Linda Knutsson
NYNirbhay N. Yadav
Nirbhay N. Yadav
SASajad Mohammed Ali
Sajad Mohammed Ali
DKDavid Olayinka Kamson
David Olayinka Kamson
EDEleni Demetriou
Eleni Demetriou
PZPeter C.M. van Zijl
Peter C.M. van Zijl
Dynamic glucose enhanced (DGE) MRI studies employ CEST or spin lock (CESL) to study glucose uptake. Currently, these methods are hampered by low effect size and sensitivity to motion. To overcome this, we propose to utilize exchange-based linewidth (LW) broadening of the direct water saturation (DS) curve of the water saturation spectrum (Z-spectrum) during and after glucose infusion (DS-DGE MRI). To estimate the glucose-infusion-induced LW changes (ΔLW), Bloch-McConnell simulations were performed for normoglycemia and hyperglycemia in blood, gray matter (GM), white matter (WM), CSF, and malignant tumor tissue. Whole-brain DS-DGE imaging was implemented at 3 T using dynamic Z-spectral acquisitions (1.2 s per offset frequency, 38 s per spectrum) and assessed on four brain tumor patients using infusion of 35 g of D-glucose. To assess ΔLW, a deep learning-based Lorentzian fitting approach was used on voxel-based DS spectra acquired before, during, and post-infusion. Area-under-the-curve (AUC) images, obtained from the dynamic ΔLW time curves, were compared qualitatively to perfusion-weighted imaging parametric maps. In simulations, ΔLW was 1.3%, 0.30%, 0.29/0.34%, 7.5%, and 13% in arterial blood, venous blood, GM/WM, malignant tumor tissue, and CSF, respectively. In vivo, ΔLW was approximately 1% in GM/WM, 5% to 20% for different tumor types, and 40% in CSF. The resulting DS-DGE AUC maps clearly outlined lesion areas. DS-DGE MRI is highly promising for assessing D-glucose uptake. Initial results in brain tumor patients show high-quality AUC maps of glucose-induced line broadening and DGE-based lesion enhancement similar and/or complementary to perfusion-weighted imaging.