Yuval Dryer

Yuval Dryer

Auto-generated profile, based on publicly available information

Yuval Dryer

Department of Geosciences, Atmospheric Science Group, Texas Tech University, Lubbock, TX, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2020 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
KAKarin Ardon-Dryer
Karin Ardon-Dryer
YDYuval Dryer
Yuval Dryer
JWJake N. Williams
Jake N. Williams
NMNastaran Moghimi
Nastaran Moghimi
The PurpleAir PA-II unit is a low-cost sensor for monitoring changes in the concentrations of particulate matter (PM) of various sizes. There are currently more than 10 000 PA-II units in use worldwide; some of the units are located in areas where no other reference air monitoring system is present. Previous studies have examined the performance of these PA-II units (or the sensors within them) in comparison to a co-located reference air monitoring system. However, because PA-II units are installed by PurpleAir customers, most of the PA-II units are not co-located with a reference air monitoring system and, in many cases, are not near one. This study aims to examine how each PA-II unit performs under atmospheric conditions when exposed to a variety of pollutants and PM2.5 concentrations (PM with an aerodynamic diameter smaller than 2.5 µm), when at a distance from the reference sensor. We examine how PA-II units perform in comparison to other PA-II units and Environmental Protection Agency (EPA) Air Quality Monitoring Stations (AQMSs) that are not co-located with them. For this study, we selected four different regions, each containing multiple PA-II units (minimum of seven per region). In addition, each region needed to have at least one AQMS unit that was co-located with at least one PA-II unit, all units needed to be at a distance of up to 5 km from an AQMS unit and up to 10 km between each other. Correction of PM2.5 values of the co-located PA-II units was implemented by multivariate linear regression (MLR), taking into account changes of temperature and relative humidity. The fit coefficients, received from the MLR, were then used to correct the PM2.5 values in all the remaining PA-II units in the region. Hourly PM2.5 measurements from each PA-II unit were compared to those from the AQMSs and other PA-II units in its region. The correction of the PM2.5 values improved the R-squared value (R2), root-mean-square error (RMSE), and mean absolute error (MAE) and slope values between all units. In most cases, the AQMSs and the PA-II units were found to be in good agreement (75 % of the comparisons had a R2>0.8); they measured similar values and followed similar trends; that is, when the PM2.5 values measured by the AQMSs increased or decreased, so did those of the PA-II units. In some high-pollution events, the corrected PA-II had slightly higher PM2.5 values compared to those measured by the AQMS. Distance between the units did not impact the comparison between units. Overall, the PA-II unit, after corrections of PM2.5 values, seems to be a promising tool for identifying relative changes in PM2.5 concentration with the potential to complement sparsely distributed monitoring stations and to aid in assessing and minimizing the public exposure to PM.

20 April 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
KAKarin Ardon-Dryer
Karin Ardon-Dryer
MKMary C. Kelley
Mary C. Kelley
XXXia Xueting
Xia Xueting
YDYuval Dryer
Yuval Dryer
Information on atmospheric particles' concentration and sizes is important for environmental and human health reasons. Air quality monitoring stations (AQMSs) for measuring particulate matter (PM) concentrations are found across the United States, but only three AQMSs measure PM2.5 concentrations (mass of particles with an aerodynamic diameter of < 2.5 µm) in the Southern High Plains of West Texas (area ≥ 1.8 × 105 km2). This area is prone to many dust events (∼ 21 yr−1), yet no information is available on other PM sizes, total particle number concentration, or size distribution during these events. The Aerosol Research Observation Station (AEROS) was designed to continuously measure these particles' mass concentrations (PM1, PM2.5, PM4, and PM10) and number concentrations (0.25–35.15 µm) using three optical particle sensors (Grimm 11-D, OPS, and DustTrak) to better understand the impact of dust events on local air quality. The AEROS aerosol measurement unit features a temperature-controlled shed with a dedicated inlet and custom-built dryer for each of the three aerosol instruments used. This article provides a description of AEROS as well as an intercomparison of the different instruments using laboratory and atmospheric particles. Instruments used in AEROS measured a similar number concentration with an average difference of 2 ± 3 cm−1 (OPS and Grimm 11-D using similar particle size ranges) and a similar mass concentration, with an average difference of 8 ± 3.6 µg m−3 for different PM sizes between the three instruments. Grimm 11-D and OPS had a similar number concentration and size distribution, using a similar particle size range and similar PM10 concentrations (mass of particles with an aerodynamic diameter of < 10 µm). Overall, Grimm 11-D and DustTrak had good agreement in mass concentration, and comparison using laboratory particles was better than that with atmospheric particles. Overall, DustTrak measured lower mass concentrations compared to Grimm 11-D for larger particle sizes and higher mass concentrations for lower PM sizes. Measurement with AEROS can distinguish between various pollution events (natural vs. anthropogenic) based on their mass concentration and size distribution, which will help to improve knowledge of the air quality in this region.

5 November 2019 in EGUsphere
Verified
Preprint
Open access
PDF file
KAKarin Ardon-Dryer
Karin Ardon-Dryer
YDYuval Dryer
Yuval Dryer
JWJake N. Williams
Jake N. Williams
NMNastaran Moghimi
Nastaran Moghimi
The PurpleAir PA-II unit is a low-cost sensor for monitoring changes in the concentrations of Particulate Matter (PM) of various sizes. There are currently more than 9000 PA-II units worldwide; some of them are located in areas where no other reference air monitoring system is present. Previous studies have examined the performance of these PA-II units (or the sensor within them) in comparison to a co-located reference air monitoring system. However, because PA-II units are installed by PurpleAir customers, the PA-II units are not co-located with a reference air monitoring system and, in many cases, are not near one. This study aimed to examine how PA-II units perform under atmospheric conditions when exposed to a variety of pollutants and PM2.5 concentrations. We were interested in knowing how accurate these PA-II units are when measuring PM2.5 concentrations with their sensitivity to concentration changes in comparison to the Environmental Protection Agency (EPA) Air Quality Monitoring Stations (AQMS) that are not co-located with them. For this study, we selected eight different locations, where each location contains multiple PA-II units (minimum of seven per location, a total of 86 units) and at least one AQMS (total of 14). PM2.5 measurements from each PA-II unit were compared to those from the AQMS and other PA-II units in its area. The comparisons were made based on hourly and daily PM2.5 measurements. In most cases, the AQMS and PA-II units were found to be in good agreement; they measured similar values and followed similar trends, that is, when the PM2.5 values measured by the AQMS increased or decreased, so did those of the PA-II. In some high-pollution events, the PA-II measured higher PM2.5 values compared to those measured by the AQMS. We found PA-II PM2.5 measurements to remain unaffected by changes in temperature or Relative Humidity (RH). Overall, the PA-II unit seems to be a promising tool for identifying relative changes in PM2.5 concentration with the potential to complement sparsely distributed monitoring stations and to aid in assessing and minimizing the public exposure to PM, particularly in areas lacking the presence of an AQMS.

4 October 2021
Verified
Other
Open access
KAKarin Ardon-Dryer
Karin Ardon-Dryer
MKMary C. Kelley
Mary C. Kelley
XXXia Xueting
Xia Xueting
YDYuval Dryer
Yuval Dryer

5 November 2019
Verified
Other
Open access
KAKarin Ardon-Dryer
Karin Ardon-Dryer
YDYuval Dryer
Yuval Dryer
JWJake N. Williams
Jake N. Williams
NMNastaran Moghimi
Nastaran Moghimi

27 October 2021
Verified
Other
Open access
PDF file
KAKarin Ardon-Dryer
Karin Ardon-Dryer
MKMary C. Kelley
Mary C. Kelley
XXXia Xueting
Xia Xueting
YDYuval Dryer
Yuval Dryer
Information on atmospheric particles’ concentration and sizes are important for environmental and human health reasons. Air quality monitor stations (AQMSs) for measuring Particulate Matter (PM) concentrations are found across the United States, but only three AQMSs measure PM2.5 concentrations (particles with an aerodynamic diameter of < 2.5 μm) in the Southern High Plains of West Texas (area ≥ 1.8 × 105 km2). This area is prone to many dust events (~21 per year), yet no information is available on other PM sizes, total particle concentration, or size distribution during these events. The Aerosol Research Observation Station (AEROS) was designed to continuously measure these particles’ concentrations to better understand the impact of dust events on local air quality. The AEROS aerosol measurements unit features a temperature-controlled shed with a dedicated inlet and custom-built dryer for each of the three aerosol instruments used. This article provides a description of AEROS as well as an intercomparison of the different instruments using laboratory and atmospheric particles, which shows that the instruments used provided similar concentration measurements. Measurement with AEROS can distinguish between various pollution events (natural dust events vs anthropogenic haze) to improve knowledge of the air quality in this region.