Karin Ardon-Dryer

Karin Ardon-Dryer

Auto-generated profile, based on publicly available information

Karin Ardon-Dryer

Department of Geosciences Atmospheric Science Group Texas Tech University Lubbock TX USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
JMJessica L. Malisch
Jessica L. Malisch
BHBreanna N Harris
Breanna N Harris
SSShanen M. Sherrer
Shanen M. Sherrer
KLKristy A. Lewis
Kristy A. Lewis
SSStephanie L. Shepherd
Stephanie L. Shepherd
JDJennifer Deitloff
Jennifer Deitloff

13 October 2020 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
KAKarin Ardon-Dryer
Karin Ardon-Dryer
YDYuval Dryer
Yuval Dryer
JWJake N. Williams
Jake N. Williams
NMNastaran Moghimi
Nastaran Moghimi
The PurpleAir PA-II unit is a low-cost sensor for monitoring changes in the concentrations of particulate matter (PM) of various sizes. There are currently more than 10 000 PA-II units in use worldwide; some of the units are located in areas where no other reference air monitoring system is present. Previous studies have examined the performance of these PA-II units (or the sensors within them) in comparison to a co-located reference air monitoring system. However, because PA-II units are installed by PurpleAir customers, most of the PA-II units are not co-located with a reference air monitoring system and, in many cases, are not near one. This study aims to examine how each PA-II unit performs under atmospheric conditions when exposed to a variety of pollutants and PM2.5 concentrations (PM with an aerodynamic diameter smaller than 2.5 µm), when at a distance from the reference sensor. We examine how PA-II units perform in comparison to other PA-II units and Environmental Protection Agency (EPA) Air Quality Monitoring Stations (AQMSs) that are not co-located with them. For this study, we selected four different regions, each containing multiple PA-II units (minimum of seven per region). In addition, each region needed to have at least one AQMS unit that was co-located with at least one PA-II unit, all units needed to be at a distance of up to 5 km from an AQMS unit and up to 10 km between each other. Correction of PM2.5 values of the co-located PA-II units was implemented by multivariate linear regression (MLR), taking into account changes of temperature and relative humidity. The fit coefficients, received from the MLR, were then used to correct the PM2.5 values in all the remaining PA-II units in the region. Hourly PM2.5 measurements from each PA-II unit were compared to those from the AQMSs and other PA-II units in its region. The correction of the PM2.5 values improved the R-squared value (R2), root-mean-square error (RMSE), and mean absolute error (MAE) and slope values between all units. In most cases, the AQMSs and the PA-II units were found to be in good agreement (75 % of the comparisons had a R2>0.8); they measured similar values and followed similar trends; that is, when the PM2.5 values measured by the AQMSs increased or decreased, so did those of the PA-II units. In some high-pollution events, the corrected PA-II had slightly higher PM2.5 values compared to those measured by the AQMS. Distance between the units did not impact the comparison between units. Overall, the PA-II unit, after corrections of PM2.5 values, seems to be a promising tool for identifying relative changes in PM2.5 concentration with the potential to complement sparsely distributed monitoring stations and to aid in assessing and minimizing the public exposure to PM.

1 February 2020 in Environmental Research
Verified
Journal Article
Closed access
KAKarin Ardon-Dryer
Karin Ardon-Dryer
CMCaroline Mock
Caroline Mock
JRJose Reyes
Jose Reyes
GLGalit Lahav
Galit Lahav

8 December 2023 in GeoHealth
Verified
Journal Article
Open access
KAK. Ardon‐Dryer
K. Ardon‐Dryer
KCK. R. Clifford
K. R. Clifford
JHJ. L. Hand
J. L. Hand
Dust is an important and complex constituent of the atmospheric system, having significant impacts on the environment, climate, air quality, and human health. Although dust events are common across many regions of the United States, their impacts are not often prioritized in air quality mitigation strategies. We argue that there are at least three factors that result in underestimation of the social and environmental impact of dust events, making them receive less attention. These include (a) sparse monitoring stations with irregular spatial distribution in dust‐influenced regions, (b) inconsistency with dust sampling methods, and (c) sampling frequency and schedules, which can lead to missed dust events or underestimation of dust particle concentrations. Without addressing these three factors, it is challenging to characterize and understand the full air quality impacts of dust events in the United States. This paper highlights the need for additional monitoring to measure these events so that we can more fully evaluate and understand their impacts, as they are predicted to increase with climate change.

1 June 2021 in Atmospheric Pollution Research
Verified
Journal Article
Closed access
MKMary C. Kelley
Mary C. Kelley
KAKarin Ardon-Dryer
Karin Ardon-Dryer

15 July 2022 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
KAKarin Ardon-Dryer
Karin Ardon-Dryer
MKMary C. Kelley
Mary C. Kelley
Dust events are an important and complex constituent of the atmospheric system that can impact Earth's climate, the environment, and human health. The frequency of dust events in the Southern High Plains of West Texas has increased over the past 2 decades, yet their impact on air quality in this region is still unclear. This is due to the fact that there is only one air quality monitoring station that measures only PM2.5 concentrations (particulate matter with an aerodynamic diameter < 2.5 µm), and there is no information on other PM sizes or the particle size distribution. The Aerosol Research Observation Station (AEROS) unit provides insight into the local variation in particle concentration during different dust events and allows for a better understanding of the impact of dust events on air quality. As this area is prone to dust events, we were wondering if dust events generated by different meteorological causes (synoptic vs. convective) would present similar particle concentrations or particle size distributions. Thus, in this project, three different dust events were measured by AEROS and compared. Each dust event originated from a different direction and lasted a different duration. One of the dust events was synoptic (10 April 2019) and two were convective (5 and 21 June 2019). Measurements of particle mass and number concentration, size distribution, and meteorological conditions for each dust event were compared. The synoptic dust event (on 10 April) was longer (12 h) and had stronger wind speed conditions (up to 22.1 m s−1), whereas the two respective convective dust events on 5 and 21 June lasted only 20 and 30 min and had lower wind speeds (up to 16.5 and 13.4 m s−1). Observation of PM based on daily and hourly values showed an impact on air quality, yet measurements based on daily and hourly values underestimate the impact of the convective dust events. Observations based on a shorter timescale (10 min) reveal the true impact of the two convective dust events. A comparison of the particle size distribution showed that all three dust events presented an increase in particles in the 0.3–10 µm size range. Comparisons of the particle concentration for particles > 5 and > 10 µm show very high values during the dust events. Some particle sizes even increase in concentration by ∼ 2 orders of magnitude compared with the time before the dust event. This leads us to speculate that the impact of convective dust events on air quality in this region is underestimated with the current (hourly basis) method.