Marina M. -C. Höhne

Marina M. -C. Höhne

Auto-generated profile, based on publicly available information

Marina M. -C. Höhne

UMI Lab Leibniz Institute of Agricultural Engineering and Bioeconomy e.V

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2015 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MVMarina M.-C. Vidovic
Marina M.-C. Vidovic
HHHan-Jeong Hwang
Han-Jeong Hwang
SASebastian Amsuss
Sebastian Amsuss
JHJanne M. Hahne
Janne M. Hahne
DFDario Farina
Dario Farina
KMKlaus-Robert Muller
Klaus-Robert Muller
Fundamental changes over time of surface EMG signal characteristics are a challenge for myocontrol algorithms controlling prosthetic devices. These changes are generally caused by electrode shifts after donning and doffing, sweating, additional weight or varying arm positions, which results in a change of the signal distribution - a scenario often referred to as covariate shift. A substantial decrease in classification accuracy due to these factors hinders the possibility to directly translate EMG signals into accurate myoelectric control patterns outside laboratory conditions. To overcome this limitation, we propose the use of supervised adaptation methods. The approach is based on adapting a trained classifier using a small calibration set only, which incorporates the relevant aspects of the nonstationarities, but requires only less than 1 min of data recording. The method was tested first through an offline analysis on signals acquired across 5 days from seven able-bodied individuals and four amputees. Moreover, we also conducted a three day online experiment on eight able-bodied individuals and one amputee, assessing user performance and user-ratings of the controllability. Across different testing days, both offline and online performance improved significantly when shrinking the training model parameters by a given estimator towards the calibration set parameters. In the offline data analysis, the classification accuracy remained above 92% over five days with the proposed approach, whereas it decreased to 75% without adaptation. Similarly, in the online study, with the proposed approach the performance increased by 25% compared to a test without adaptation. These results indicate that the proposed methodology can contribute to improve robustness of myoelectric pattern recognition methods in daily life applications.

10 July 2024
Verified
Book Chapter
Closed access
PDF file
AHAnna Hedström
Anna Hedström
LWLeander Weber
Leander Weber
SLSebastian Lapuschkin
Sebastian Lapuschkin
MHMarina Höhne
Marina Höhne

30 July 2025 in Machine Learning: Earth
Verified
Journal Article
Open access
PBPhiline L Bommer
Philine L Bommer
MKMarlene Kretschmer
Marlene Kretschmer
FSFiona R Spuler
Fiona R Spuler
KBKirill Bykov
Kirill Bykov
MHMarina M-C Höhne
Marina M-C Höhne

21 January 2024
Verified
Book Chapter
Closed access
PDF file
KBKirill Bykov
Kirill Bykov
KMKlaus-Robert Müller
Klaus-Robert Müller
MHMarina M.-C. Höhne
Marina M.-C. Höhne

3 December 2025 in Results in Engineering
Verified
Journal Article
Open access
MBMajharulislam Babor
Majharulislam Babor
SLShanghua Liu
Shanghua Liu
AAArman Arefi
Arman Arefi
Agata Olszewska-WiddratAgata Olszewska-Widdrat
Agata Olszewska-Widdrat
Joachim VenusJoachim Venus
Joachim Venus
MHMarina M.-C. Höhne
Marina M.-C. Höhne

12 May 2025
Verified
Book Chapter
Closed access
PDF file
KWKristoffer Knutsen Wickstrøm
Kristoffer Knutsen Wickstrøm
MHMarina Höhne
Marina Höhne
AHAnna Hedström
Anna Hedström