Parvathy Nair

Parvathy Nair

Auto-generated profile, based on publicly available information

Parvathy Nair

Division of Cardiology, Department of Medicine, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2010 in BMC Medical Education
Verified
Journal Article
Open access
PDF file
DSDavid Shanks
David Shanks
RWRoger Y Wong
Roger Y Wong
JRJames M Roberts
James M Roberts
PNParvathy Nair
Parvathy Nair
IMIrene Wy Ma
Irene Wy Ma
Simulation is increasingly used for teaching medical procedures. The goal of this study was to assess learner preferences for how simulators should be used in a procedural curriculum.

1 June 2021 in Canadian Journal of Cardiology
Verified
Journal Article
Closed access
AAAws Almufleh
Aws Almufleh
CLChristopher Lee
Christopher Lee
MTMichael Yc Tsang
Michael Yc Tsang
KGKenneth Gin
Kenneth Gin
TTTeresa S.M. Tsang
Teresa S.M. Tsang
PNParvathy Nair
Parvathy Nair

9 February 2024 in Diseases
Verified
Journal Article
Open access
PDF file
NLNelson Lu
Nelson Lu
HVHooman Vaseli
Hooman Vaseli
MMMobina Mahdavi
Mobina Mahdavi
FDFatemah Taheri Dezaki
Fatemah Taheri Dezaki
CLChristina Luong
Christina Luong
TTTeresa Tsang
Teresa Tsang
Background: Automated rhythm detection on echocardiography through artificial intelligence (AI) has yet to be fully realized. We propose an AI model trained to identify atrial fibrillation (AF) using apical 4-chamber (AP4) cines without requiring electrocardiogram (ECG) data. Methods: Transthoracic echocardiography studies of consecutive patients ≥ 18 years old at our tertiary care centre were retrospectively reviewed for AF and sinus rhythm. The study was first interpreted by level III-trained echocardiography cardiologists as the gold standard for rhythm diagnosis based on ECG rhythm strip and imaging assessment, which was also verified with a 12-lead ECG around the time of the study. AP4 cines with three cardiac cycles were then extracted from these studies with the rhythm strip and Doppler information removed and introduced to the deep learning model ResNet(2+1)D with an 80:10:10 training–validation–test split ratio. Results: 634 patient studies (1205 cines) were included. After training, the AI model achieved high accuracy on validation for detection of both AF and sinus rhythm (mean F1-score = 0.92; AUROC = 0.95). Performance was consistent on the test dataset (mean F1-score = 0.94, AUROC = 0.98) when using the cardiologist’s assessment of the ECG rhythm strip as the gold standard, who had access to the full study and external ECG data, while the AI model did not. Conclusions: AF detection by AI on echocardiography without ECG appears accurate when compared to an echocardiography cardiologist’s assessment of the ECG rhythm strip as the gold standard. This has potential clinical implications in point-of-care ultrasound and stroke risk stratification.

1 January 2023 in Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
JYJeffrey Yim
Jeffrey Yim
MTMichael Y.C. Tsang
Michael Y.C. Tsang
AVAnand Venkataraman
Anand Venkataraman
SBShane Balthazaar
Shane Balthazaar
KGKen Gin
Ken Gin
TTTeresa Tsang
Teresa Tsang
Yim J, et al. J Cardiovasc Imaging. 2023 Mar;31:e18. https://doi.org/10.4250/jcvi.2022.0120

1 November 2023 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
JWJeffrey D. Wong
Jeffrey D. Wong
SFSarah J. Finlayson
Sarah J. Finlayson
JLJonathan M Loree
Jonathan M Loree
LSLynn Straatman
Lynn Straatman
PNParvathy Nair
Parvathy Nair
DYDarwin Yeung
Darwin Yeung

22 June 2025 in Diseases
Verified
Journal Article
Open access
PDF file
ARAishwarya Roshan
Aishwarya Roshan
JYJeffrey Yim
Jeffrey Yim
SLShamikh Lakhani
Shamikh Lakhani
JWJennifer Wang
Jennifer Wang
ASAamiya Sidhu
Aamiya Sidhu
TTTeresa Tsang
Teresa Tsang
Background: Despite its high prevalence, little is known about the effect of sex on the management and outcomes of aortic stenosis (AS). We sought to characterize the effect of sex on the clinical evaluation for and provision of aortic valve replacement (AVR), including surgical (SAVR) and transcatheter aortic valve replacement (TAVR), and the subsequent morbidity and mortality outcomes. Methods: A comprehensive chart review was conducted on all patients with a first diagnosis of severe aortic stenosis (AS) at Vancouver General and University of British Columbia hospitals from 2012 to 2022. Exact chi-square and Kruskal–Wallis tests were used to evaluate the variables of interest. Results: A total of 1794 studies met the inclusion criteria, comprising 782 females (44%) and 1012 males (56%). Females were significantly older than males at the time of the first diagnosis (79 versus 75 years, p < 0.001). Females were significantly less likely to be evaluated by the TAVR clinic or cardiac surgeon or to receive aortic valve intervention (p-value ≤ 0.001). Females were significantly more likely to be rejected for TAVR due to older age (OR 0.23 (0.07, 0.59)), comorbid conditions (OR 0.68 (0.47, 0.97)), and frailty (OR 0.23 (0.07, 0.59)). Females were significantly more likely to be rejected for SAVR on the basis of frailty (OR 0.66 (0.46, 0.94)). Females also had significantly higher rates of 1-year mortality, hospitalization, and heart failure hospitalization compared to males (p-values < 0.05). Conclusions: Our data suggest significant sex-based discrepancies in the management of AS. Females with severe AS are diagnosed later in life and are less likely to be evaluated for valve intervention. They are less likely to receive intervention due to older age, frailty, and multimorbid conditions. Further research is warranted for a more effective identification and follow up of aortic stenosis, as well as timely referral for AVR, where appropriate, especially for females.