Mamurzhon A. Makhmudov

Mamurzhon A. Makhmudov

Auto-generated profile, based on publicly available information

Mamurzhon A. Makhmudov

Meshalkin National Medical Research Center

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2023 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
ABA.A. Baranov
A.A. Baranov
OKO.V. Krestyaninov
O.V. Krestyaninov
ABA.G. Badoian
A.G. Badoian
DKDmitrii Khelimskii
Dmitrii Khelimskii
SMS.N. Manukian
S.N. Manukian
MMM.A. Makhmudov
M.A. Makhmudov
Background: Transcatheter aortic valve implantation (TAVI) is an effective and safe procedure for severe aortic stenosis. Increased aortic root angulation is an important anatomical feature that may cause technical difficulties and negatively affect immediate and long-term outcomes.Objective: To evaluate immediate outcomes of TAVI in patients with increased aortic root angulation.Methods: Our retrospective single-center study included 412 patients with severe aortic stenosis who underwent TAVI using self-expanding bioprostheses from 2015 to 2022. Patients with aortic root angulation ≥ 49° were included in group 1 (n = 200), and those with aortic root angulation < 49° comprised group 2 (n = 212).Results: The mean age of the patients was 75.2 ± 7.2 years. In a subgroup with the first-generation CoreValve prosthesis and a ≥ 49° angle, we observed moderate aortic regurgitation significantly more often (7.4% vs 0.0%, P = .010) and technical success significantly less often (90.1% vs 98.9%, P = .010) compared with a similar subgroup with a < 49° angle. In subgroups with CoreValve Evolute R and ACURATE neo prostheses, there were no significant differences in terms of the mentioned parameters. Independent predictors of technical failure were the aortic root angle [OR for each degree increase: 0.44, 95% CI: 0.30-0.63, P < .001], no postdilation [OR: 5.0, 95% CI: 1.33-20.00, P = .074], indexed mass of the left ventricular myocardium [OR: 1.02, 95% CI: 1.01-1.03, P = .003], and higher implantation relative to the aortic annulus [OR for every 1 mm decrease in implantation depth: 0.44, 95% CI: 0.30-0.63, P < .001].Conclusion: Increased aortic angulation ≥ 49° negatively affected the technical success of TAVI only in patients with the first-generation CoreValve prostheses. Independent predictors of technical failure in TAVI were the aortic root angle, no postdilation, indexed mass of the left ventricular myocardium, and higher implantation relative to the aortic annulus. Received 9 January 2023. Revised 10 May 2023. Accepted 30 May 2023. Funding: The study did not have sponsorship. Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: A.A. Baranov, O.V. Krestyaninov, D.A. Khelimskii, A.G. BadoianData collection and analysis: A.A. Baranov, O.V. Krestyaninov, D.A. Khelimskii, A.G. BadoianStatistical analysis: A.A. Baranov, O.V. Krestyaninov, D.A. Khelimskii, A.G. BadoianDrafting the article: A.A. Baranov, O.V. Krestyaninov, D.A. Khelimskii, A.G. Badoian, S.N. Manukian, A.Yu. Tsydenova, M.A. MakhmudovCritical revision of the article: A.A. Baranov, O.V. Krestyaninov, D.A. Khelimskii, A.G. Badoian, S.N. Manukian, A.Yu. Tsydenova, M.A. MakhmudovFinal approval of the version to be published: A.A. Baranov, O.V. Krestyaninov, D.A. Khelimskii, A.G. Badoian, S.N. Manukian, A.Yu. Tsydenova, M.A. Makhmudov

14 October 2025 in Russian Journal of Cardiology
Verified
Journal Article
Open access
PDF file
ABA. G. Badoyan
A. G. Badoyan
ABA. A. Baranov
A. A. Baranov
MMM. A. Makhmudov
M. A. Makhmudov
OKO. V. Krestyaninov
O. V. Krestyaninov
VBV. P. Borodin
V. P. Borodin
ADAnna Dokuchaeva
Anna Dokuchaeva
Endovascular embolization using coils is a widely used method for treating various vascular pathologies. There are many types of coils, differing in design, material and technical characteristics, which allows choosing the best options depending on the clinical setting. The article discusses the main types of endovascular coils and their technical features. The final part presents cases of successful use of endovascular embolization coils and stopping bleeding, demonstrating its high potential and important role in modern interventional therapy.

18 December 2025 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
АБАлексей Алексеевич Баранов
Алексей Алексеевич Баранов
ABAram G. Badoyan
Aram G. Badoyan
DKDmitrii Khelimskii
Dmitrii Khelimskii
ATAryuna Yu. Tsydenova
Aryuna Yu. Tsydenova
MMMamur A. Makhmudov
Mamur A. Makhmudov
МMМамуржон Али Угли Maхмудов
Мамуржон Али Угли Maхмудов
Background: Comparative studies demonstrate commensurate longterm survival rates after surgical myectomy and alcohol septal ablation in patients with hypertrophic obstructive cardiomyopathy, although endovascular interventions are associated with a less pronounced decrease in the obstruction gradient and an increased rate of repeat procedures. Considering the proven interrelations between residual pressure gradient and long-term survival, identification of factors affecting the hemodynamic efficacy of alcohol septal ablation is of particular clinical importance for improving selection criteria for patient and optimizing therapeutic оutcomes. Objective: The study was aimed at assessment of short-term results ofalcohol septal ablation and the detection of predictors for procedural failure of the intervention. Methods: This retrospective single-center study included 71 patients with hypertrophic obstructive cardiomyopathy who underwent septalalcohol ablation. The criterion for procedural failure of the intervention was considered to be the retention of the residual pressure gradient in the leftventricular outflow tract of ≥30 mm Hg at rest and/or the provoked gradientof ≥50 mm Hg at the time of patient discharge. The primary endpoint waspredictors of technical failure. Secondary endpoints included technical failure, in-hospital complications, and echocardiographic parameters. Results: The rate of procedural failure was 26.8 % (19/71). In the postoperative period, a significant decrease in the pressure gradient in the left ventricular outflow tract was from 77 mm Hg (64, 95) to 27 mm Hg (19, 45) (p < 0.001). There were no cases of acute cerebrovascular accident and hospital mortality. Implantation of a permanent pacemaker was required in 4.3 % of cases. Independent predictors of procedural failure of alcohol septal ablation included initial values of left ventricular endsystolic volume (OR 1.08, 95 % CI 1.02–1.16, p = 0.023) and left ventricular end-diastolic volume (OR 1.10, 95 % CI 1.04–1.19, p = 0.019), as well as left ventricular posterior wall thickness (OR 1.40, 95 % CI 1.06–1.96, p = 0.030). Conclusion: This study presents the experience of alcohol septal ablationin a single center. Procedural success of the intervention was significantlyassociated with initial left ventricular end-systolic volume, initial leftventricular end-diastolic volume, and left ventricular posterior wall thickness

13 December 2025 in Russian neurological Journal
Verified
Journal Article
Closed access
KSK. V. Shalygin
K. V. Shalygin
OKO. V. Krestyaninov
O. V. Krestyaninov
ABA. G. Badoian
A. G. Badoian
ABA. A. Baranov
A. A. Baranov
MMM. A. Makhmudov
M. A. Makhmudov
Objective. To assess the long-term outcomes of endovascular treatment in patients with aneurysmal subarachnoid hemorrhage (SAH) who underwent endovascular treatment within 72 hours from the onset of hemorrhage. Material and Methods. The study included 120 patients who underwent endovascular embolization of a ruptured cerebral aneurysm during the acute phase of SAH. Patients were stratified into two groups: early (n = 60) and ultra-early (n = 60) embolization. Functional outcomes were evaluated using the modified Rankin Scale (mRS) with long-term follow-up of up to 10 years. Results. Long-term data were available for 101 of the 120 patients (84.2%). A favorable outcome (mRS 0–2) was recorded in 72.3% of patients, moderate to severe neurological deficit (mRS 3–5) in 5.0%, and long-term mortality was 23.8%. Survival analysis revealed no significant differences between the early and ultra-early embolization groups (p = 0.924). Multivariate analysis confirmed a significant impact of age and the degree of occlusion according to the Raymond–Roy classification on prognosis. Conclusion. Endovascular embolization demonstrates high efficacy in the treatment of ruptured aneurysms, providing favorable functional outcomes in the majority of patients. The timing of intervention (early vs. ultra-early) does not significantly affect long-term survival.

14 January 2026 in Kardiologiia
Verified
Journal Article
Open access
PDF file
ABA. A. Baranov
A. A. Baranov
ABA. G. Badoian
A. G. Badoian
DKDmitrii Khelimskii
Dmitrii Khelimskii
AСA. Yu. Сydenova
A. Yu. Сydenova
MMM. A. Makhmudov
M. A. Makhmudov
OKO. V. Krestyaninov
O. V. Krestyaninov
Aim To evaluate the efficacy and safety of a new 3D navigation-guided technique for transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis (AS) and a high risk of atrioventricular (AV) conduction disorder. Material and methods The study presents the results of a single-center prospective randomized pilot study. Sixty patients meeting inclusion and exclusion criteria with at least one criterion of a high risk for AV conduction disorder were enrolled in the study. All included patients were randomized 1:1 into two groups. In Group 1, TAVI was performed using a 3D navigation-guided technique, while in Group 2, the classical TAVI technique was used. The primary endpoint was the composite incidence of permanent pacemaker (PP) implantation and new-onset complete left bundle branch block (LBBB) at 6 months. Results In the early postoperative period, the 3D navigation-guided TAVI group had a lower incidence of new-onset LBBB (10.3% vs . 33.3%; p =0.03), better parameters of intraventricular conduction according to electrophysiology study (EPS) (H-V interval 79.1±13.5 ms vs . 96.0±39.9 ms; p =0.03) and electrocardiography (QRS complex duration 108.0±16.3 ms vs . 119.0±22.6 ms; p =0.04). The incidence of PP implantation during the hospital stage, A-H interval duration, and Wenckebach point in the AV junction according to EPS did not differ significantly between the groups. The incidence of the primary endpoint (PP implantation + new-onset LBBB) during the 6-month follow-up period was 43.3% in the classical technique group and 16.7% in the 3D navigation-guided TAVI group ( p =0.02). There were no statistically significant differences between the groups in the incidence of procedural complications or major adverse cardiovascular and cerebrovascular outcomes. Conclusion This study demonstrated the efficacy and safety of a new 3D navigation-guided TAVI technique in reducing the composite rate of implantation PP and LBBB at 6 months post-procedure, with comparable rates of procedural complications and major adverse cardiac and cerebrovascular events (MACCE) during long-term follow-up. Implementation of these findings into clinical practice will enable personalization and optimization of transcatheter treatment outcomes in patients with severe AS.

13 August 2026 in Russian Journal of Cardiology
Verified
Journal Article
Open access
PDF file
ATA. Yu. Tsydenova
A. Yu. Tsydenova
ABA. G. Badoyan
A. G. Badoyan
ABA. A. Baranov
A. A. Baranov
MMM. M. Makhmudov
M. M. Makhmudov
SZSh. Sh. Zainobidinov
Sh. Sh. Zainobidinov
ОКО. В. Крестьянинов
О. В. Крестьянинов
Aim . To compare the procedural, inhospital, and mid-term outcomes of two stra­tegies for preparing coronary artery calcification. Material and methods . A clinical analysis of treatment outcomes was performed in 88 patients with severe coronary artery calcification who underwent surgery between 2022 and 2024. Percutaneous coronary intervention with stenting was performed. Patients were randomized 1:1 to calcification preparation using a combining rotational atherectomy with cutting balloon angioplasty or rotational athe­rectomy with high-pressure balloon angioplasty. Two patients (2,2%) underwent surgery for unstable angina, and 86 (97,8%) patients had stable angina. We assessed the procedure technical success, the need to modify the lesion pre­paration strategy, periprocedural complications, and the inhospital and 30-day postoperative periods. Results . Technical success was achieved in 100% of cases in both study groups. However, in 8 patients (18%) who did not achieve optimal calcification preparation criteria, rotational atherectomy and a high-pressure balloon preparation were switched to combining rotational atherectomy with cutting balloon angioplasty. The radial artery was the most common access for endovascular intervention (78,4% of cases). Periprocedural myocardial infarction was not recorded. In all cases, patients were managed conservatively in the postoperative period, and repeat intervention was not required. Conclusion . Combining rotational atherectomy with cutting balloon angioplasty demonstrates comparable safety and efficacy to rotational atherectomy combined with a high-pressure balloon angioplasty. Intravascular ultrasound is a key factor in optimizing treatment strategy and deciding whether to switch strategies. This method can be used as a primary strategy for calcification modification, as well as when high-pressure balloon angioplasty is ineffective.