1 April 1994 in Analytical Chemistry
15 April 1995 in Journal of Applied Physics
It is well known that bimetallic microcantilevers can exhibit static deflection as a result of thermal effects, including exothermic adsorption of chemicals on their surfaces. It is shown here that the resonance frequency of a cantilever can change due to a combination of mass loading and change of spring constant resulting from adsorption of chemicals on the surface. Cantilevers also undergo static bending that is induced by differential surface stress. The magnitude of these effects depends upon the chemical properties of the surface and upon the amount of material adsorbed. Hence cantilever deflection as well as resonance frequency change can be used as the basis for development of novel chemical sensors.
1 January 1989 in Physical Review B
The exponential decay of the evanescent field due to the total internal reflection (TIR) of a light beam in a prism is used to advantage in a new form of scanning optical microscope, the photon scanning tunneling microscope (PSTM). The PSTM is the photon analogue of the electron scanning tunneling microscope. The sample is placed on or forms the TIR surface and spatially modulates the evanescent field. Changes in intensity are monitored by a probe tip scanned over the surface, and the data are processed to generate an image of the sample. Subwavelength resolution in three dimensions is obtained because of the exponential nature of the evanescent field intensity. Images produced by a prototype instrument using 633-nm light and a 1-μm probe tip are shown to have a lateral resolution of about 200 nm.
27 March 1995 in Applied Physics Letters
Oscillating silicon nitride microcantilevers coated with a thin gold film have been used to detect mercury vapor in air. Cantilever resonance frequency changes due to surface mass loading as a result of adsorption of mercury vapor. Furthermore, cantilever bending is also altered due to changes in surface stress induced by mercury adsorption on the gold overlayer. Both of these phenomena can be used to quantitatively detect adsorbed vapors with picogram mass resolution.
23 May 1994 in Applied Physics Letters
The deflection of scanning force microscope cantilevers, metal coated on one side, is significantly influenced by both thermal heating and variations in relative humidity. For constant relative humidity, the deflection of the cantilever drifts due to laser heating and eventually reaches a steady-state value. For a thermally stabilized cantilever, the deflection varies linearly with relative humidity. Exposure to other vapors, such as mercury, changes the inherent deflection of the cantilever. Relative amounts of adsorbates on the cantilever can be estimated from shifts in the cantilever resonance frequency with picogram mass resolution. The cantilever deflection as well as changes in resonance frequency due to vapor adsorption can be used as basis for novel chemical sensors.
1 August 1994 in Review of Scientific Instruments
A variational method is used to calculate the deflection and the fundamental and harmonic resonance frequencies of commercial V‐shaped and rectangular atomic force microscopy cantilevers. The effective mass of V‐shaped cantilevers is roughly half that calculated for the equivalent rectangular cantilevers. Damping by environmental gases, including air, nitrogen, argon, and helium, affects the frequency of maximum response and to a much greater degree the quality factor Q. Helium has the lowest viscosity, resulting in the highest Q, and thus provides the best sensitivity in noncontact force microscopy. Damping in liquids is dominated by an increase in effective mass of the cantilever due to an added mass of the liquid being dragged with that cantilever.