Xiu Yang

Xiu Yang

Auto-generated profile, based on publicly available information

Xiu Yang

Shanghai University of Electric Power, Shanghai, China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in CIRED - Open Access Proceedings Journal
Verified
Journal Article
Open access
JSJie Song
Jie Song
ZXZhenzhen Xie
Zhenzhen Xie
JZJian Zhou
Jian Zhou
XYXiu Yang
Xiu Yang
APAiqiang Pan
Aiqiang Pan
Here, a methodology based on cluster analysis, feature selection, and support vector machine (SVM) is presented to predict power quality indexes such as harmonic distortion and voltage deviation. First, cluster analysis is made on power quality index data, and historical data sets to be used are selected according to the classification of the data to be predicted. Then, with the feature selection algorithm, the optimal factor combination relevant to the power quality index to be predicted is obtained from several factors, such as weather, active power, reactive power, and others. Finally, the historical data and associated factor data are taken as the training sample data sets to establish the SVM prediction model. Through the analysis of the actual sample data during 2013 and 2014 in a certain area of Shanghai, China, it is proved that the average relative error of this method is greatly improved.

12 February 2019 in IEEE Transactions on Device and Materials Reliability
Verified
Journal Article
Closed access
YXYang Xiu
Yang Xiu
NTNicholas Thomson
Nicholas Thomson
ERElyse Rosenbaum
Elyse Rosenbaum
On-chip supply noise induced by power-on ESD is studied with the aid of on-chip monitor circuits and circuit simulation. The monitor circuits' outputs provide information about the magnitudes of the ESD-induced supply noise. The supply noise monitor circuits were implemented on a 130-nm CMOS test chip. Voltage monitor circuits record the maximum and minimum supply voltage excursions. Flip-flop monitor circuits respond to a rapid voltage change at the supply. Circuit simulation is used to validate hypotheses about how the noise spreads throughout the power delivery network.

1 July 2020 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
YXYang Xiu
Yang Xiu
ERElyse Rosenbaum
Elyse Rosenbaum
This work studies the effect of system-level ESD on chip-level power integrity of ICs. The analysis reveals that isolating the ground nets of the various on-chip power domains impedes the cross-domain propagation of ESD-induced supply noise. Further analysis as well as circuit simulation show that an integrated voltage regulator (IVR) can provide increased immunity to ESD-induced supply noise, especially if the internally generated power supply does not utilize any PCB-level decoupling capacitors. However, the IVR's PMOS pass transistor may discharge the internally regulated supply if the IO supply domain collapses due to ESD. Key findings of the analysis are confirmed by measurements performed on two test chips which have differing IVR designs.

18 June 2021
Verified
Conference Paper
Closed access
DWDingmei Wang
Dingmei Wang
QZQiang Zhou
Qiang Zhou
WSWeicheng Shen
Weicheng Shen
DGDanzhen Gu
Danzhen Gu
XYXiu Yang
Xiu Yang
Building a dynamic equivalent model that can accurately describe the dynamic characteristics of power grid with wind farms is the basis of studying the operation and control of power system with high proportion of wind power. In this paper, a practical method of wind farm clustering modeling for power grid dynamic equivalence is proposed. The dynamic equivalence of wind farms is carried out step by step, and the equivalence of clusters, wind farms and networks with multiple wind farms is completed in turn; The calculation formula of aggregate equivalence of parameters of each part is given. The effectiveness of the method is verified by an example.

3 January 2012 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
HZHai Yang Zang
Hai Yang Zang
XYXiu Yang
Xiu Yang
As the power output of the photovoltaic (PV) cell changes with the insolation changing, PV cell temperature and cell voltage changing, it is necessary to control the operating voltage to draw the maximum power of the PV cell in order to increase system efficiency. Two-level three phase grid-connected PV system is designed. The forestage BOOST chopper adopt Incremental conductance algorithm to implement Maximum Power Point Tracking; The controller for the inverter system contains inner current loop and external voltage loop. According to the proposed control schemes, the phase and frequency of grid-connected current is the same as grid voltage, with the result of unity of the power, factor for power grid. The PV grid-connected system is built by MATLAB/SIMULINK, and the simulation results show that the proposed control schemes are validated.