Lu Jiang

Lu Jiang

Auto-generated profile, based on publicly available information

Lu Jiang

The University of Maryland

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2006 in Journal of Food Engineering
Verified
Journal Article
Closed access
LJLu Jiang
Lu Jiang
BZBin Zhu
Bin Zhu
XRXiuqin Rao
Xiuqin Rao
GBGerald Berney
Gerald Berney
Yang TaoYang Tao
Yang Tao

10 July 2007 in Sensing and Instrumentation for Food Quality and Safety
Verified
Journal Article
Closed access
PDF file
BZBin Zhu
Bin Zhu
LJLu Jiang
Lu Jiang
FJFenghua Jin
Fenghua Jin
LQLei Qin
Lei Qin
AVAbby Vogel
Abby Vogel
Yang TaoYang Tao
Yang Tao

9 November 2005
Verified
Conference Paper
Closed access
PDF file
BZBin Zhu
Bin Zhu
LJLu Jiang
Lu Jiang
XCXuemei Cheng
Xuemei Cheng
Yang TaoYang Tao
Yang Tao
Machine vision methods are widely used in apple defect detection and quality grading applications. Currently, 2D near-infrared (NIR) imaging of apples is often used to detect apple defects because the image intensity of defects is different from normal apple parts. However, a drawback of this method is that the apple calyx also exhibits similar image intensity to the apple defects. Since an apple calyx often appears in the NIR image, the false alarm rate is high with the 2D NIR imaging method. In this paper, a 2D NIR imaging method is extended to a 3D reconstruction so that the apple calyx can be differentiated from apple defects according to their different 3D depth information. The Lambertian model is used to evaluate the reflectance map of the apple surface, and then Pentland's Shape-From-Shading (SFS) method is applied to reconstruct the 3D surface information of the apple based on Fast Fourier Transform (FFT). Pentland's method is directly derived from human perception properties, making it close to the way human eyes recover 3D information from a 2D scene. In addition, the FFT reduces the computation time significantly. The reconstructed 3D apple surface maps are shown in the results, and different depths of apple calyx and defects are obtained correctly.

8 March 2007
Verified
Conference Paper
Closed access
LJLu Jiang
Lu Jiang
KSKhan Siddiqui
Khan Siddiqui
BZBin Zhu
Bin Zhu
Yang TaoYang Tao
Yang Tao
ESEliot Siegel
Eliot Siegel
During the last decade, x-ray computed tomography (CT) has been applied to screen large asymptomatic smoking and nonsmoking populations for early lung cancer detection. Because a larger population will be involved in such screening exams, more and more attention has been paid to studying low-dose, even ultra-low-dose x-ray CT. However, reducing CT radiation exposure will increase noise level in the sinogram, thereby degrading the quality of reconstructed CT images as well as causing more streak artifacts near the apices of the lung. Thus, how to reduce the noise levels and streak artifacts in the low-dose CT images is becoming a meaningful topic. Since multi-slice helical CT has replaced conventional stop-and-shoot CT in many clinical applications, this research mainly focused on the noise reduction issue in multi-slice helical CT. The experiment data were provided by Siemens SOMATOM Sensation 16-Slice helical CT. It included both conventional CT data acquired under 120 kvp voltage and 119 mA current and ultra-low-dose CT data acquired under 120 kvp and 10 mA protocols. All other settings are the same as that of conventional CT. In this paper, a nonparametric smoothing method with thin plate smoothing splines and the roughness penalty was proposed to restore the ultra-low-dose CT raw data. Each projection frame was firstly divided into blocks, and then the 2D data in each block was fitted to a thin-plate smoothing splines' surface via minimizing a roughness-penalized least squares objective function. By doing so, the noise in each ultra-low-dose CT projection was reduced by leveraging the information contained not only within each individual projection profile, but also among nearby profiles. Finally the restored ultra-low-dose projection data were fed into standard filtered back projection (FBP) algorithm to reconstruct CT images. The rebuilt results as well as the comparison between proposed approach and traditional method were given in the results and discussions section, and showed effectiveness of proposed thin-plate based nonparametric regression method.