Tianhua Zhu

Tianhua Zhu

Auto-generated profile, based on publicly available information

Tianhua Zhu

Department of Energy (AAU Energy), Aalborg University, Aalborg, Denmark

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FZFangzhou Zhao
Fangzhou Zhao
XWXiongfei Wang
Xiongfei Wang
TZTianhua Zhu
Tianhua Zhu
This article proposes a grid-forming based decoupling approach, which effectively mitigates the dynamic interactions between active and reactive power, especially suitable for system stabilization in ultrastrong grids with short-circuit ratio over 30. The physical coupling behaviors are first revealed by analytical studies, where two potential resonances, respectively, located in 40–50 Hz and 0–10 Hz are discovered with mathematical proofs. Based on the results, the decoupling controller is then designed with transfer function approximation for practical usage. The control method not only suppresses the couplings but also cancels two pairs of conjugate poles through decoupling paths. Thanks to the cancellation, the stability margin is remarkably increased in stiff grids, and therefore, a significant bandwidth boost on the power synchronization control can be realized if desired. The experimental results are finally performed to verify the proposed decoupling method.

4 March 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TZTianhua Zhu
Tianhua Zhu
FZFang Zhuo
Fang Zhuo
FZFangzhou Zhao
Fangzhou Zhao
FWFeng Wang
Feng Wang
HYHao Yi
Hao Yi
TZTong Zhao
Tong Zhao
The CLLC resonant converters are drawing more and more attention for their superiority in soft switching, wide output range and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and low efficiency under light-load conditions. Therefore, this paper proposes an optimization for extended phase-shift (EPS) control in full-bridge CLLC resonant converter to improve the light-load efficiency. In order to study the relations between phase-shifts of EPS control and converter efficiency, a detailed circuit model is first established to solve the voltage gain, time-domain expressions of main circuit variables and root mean square (RMS) values of resonant currents. Then, a comprehensive loss evaluation is conducted by calculating and analyzing the main power losses, including conduction loss, switching loss and core losses of magnetic components. Besides, zero voltage switching (ZVS) conditions of primary and rectifier switches are derived to define the range of soft switching. Finally, based on these analyses, the optimal combination of phase-shifts for EPS control is determined to achieve the maximum conversion efficiency of full-bridge CLLC converter at light-load conditions. The validity of the proposed optimized EPS control is verified on a 18~25V/400V, 200W GaN based CLLC resonant converter prototype.

5 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FZFangzhou Zhao
Fangzhou Zhao
TZTianhua Zhu
Tianhua Zhu
ZLZejie Li
Zejie Li
XWXiongfei Wang
Xiongfei Wang
Grid-forming voltage-source converter (GFM-VSC) may experience low-frequency resonances, such as synchronous resonance (SR) and subsynchronous resonance (SSR), in the output power. This article provides a comprehensive study on the low-frequency resonances with GFM-VSC systems and damping control methods. First, the causes of SR and SSR are discussed, highlighting the impacts of control interactions on the resonances. Then, a systematic study of the recent advancements in stabilizing control methods for SR and SSR is presented. Specific physical insights into different damping effects on SR and SSR under weak and stiff grid conditions are revealed and summarized. Furthermore, experimental results comparing the dynamic performances of different damping controls are provided, corroborating the insights obtained in this study. Finally, perspectives on future research trends are shared.

1 November 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
FZFangzhou Zhao
Fangzhou Zhao
XWXiongfei Wang
Xiongfei Wang
TZTianhua Zhu
Tianhua Zhu
This paper presents a passivity-based analysis and damping method for the low-frequency dynamics of grid-forming (GFM) control. A closed-form analytical solution to the positive realness of control input admittance is developed, which reveals the inherent non-passive property of GFM control. This feature gives rise to the risk of instability, especially in connection with a nearby non-passive GFM inverter, which may induce undesired control interactions. It is further revealed that the passivity index is determined by a low-frequency resonance around 10 Hz in the dq-frame, and this resonance can be better dampened, therefore with enhanced passivity index, by using a virtual reactance than using a virtual resistance. Finally, the theoretical findings are verified by the experimental results.

29 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FZFangzhou Zhao
Fangzhou Zhao
GXGuochun Xiao
Guochun Xiao
TZTianhua Zhu
Tianhua Zhu
XZXu Zheng
Xu Zheng
ZWZhiqian Wu
Zhiqian Wu
TZTong Zhao
Tong Zhao
The low-frequency fluctuation over the capacitor voltages seriously limits the development of the medium-voltage variable-speed drives with Modular Multilevel Converter (MMC). Therefore, this paper presents an effective strategy of the lowspeed and start-up operation for MMC based motor drive. The proposed strategy properly coordinates the improved injection and the reduced average capacitor voltage with high applicability. The specific interactions between the control parameters and the system metrics are analyzed to give the detailed steps of the parameters designing. Hence, based on the derivations, the proposed method enables the low-frequency operation under the nominal load torque with decreased injected components and reduced peak capacitor voltages. What's more, two start-up strategies that respectively aim at different objectives for the coordinated strategy are proposed, indicating satisfying control performances for the practical applications. The injected common-mode voltage and circulating current in the proposed method are designed to have a great reduction. Thus, the unfavorable risks for the motor is evidently decreased for better stability. The reduced peak current also lessens the high stress on the switching devices with desirable reliability. The simulation and experiment results on an MMC based motor drive prototype prove the effectiveness and superiority of the proposed method.

21 November 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FZFangzhou Zhao
Fangzhou Zhao
XWXiongfei Wang
Xiongfei Wang
ZZZichao Zhou
Zichao Zhou
YSYin Sun
Yin Sun
LHLennart Harnefors
Lennart Harnefors
TZTianhua Zhu
Tianhua Zhu
This letter proposes a grid-forming control scheme that is robust against a wide range of short-circuit ratio (SCR) of the ac grid. The approach modifies the traditional power synchronization control by adding an active susceptance loop, which enhances system damping for high stability robustness and enables to use a standard voltage-oriented vector current control. The latter can avoid major software changes on a classical grid-following control structure. Both small-signal dynamics analysis and experimental results confirm the effectiveness of the approach from ultraweak (SCR = 1, X / R ratio = 7) to stiff (SCR = 38.5) grids.