Fangzhou Zhao

Fangzhou Zhao

Auto-generated profile, based on publicly available information

Fangzhou Zhao

Tsinghua University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2022 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
BFBo Fan
Bo Fan
TLTeng Liu
Teng Liu
FZFangzhou Zhao
Fangzhou Zhao
HWHeng Wu
Heng Wu
XWXiongfei Wang
Xiongfei Wang
Grid-forming (GFM) inverters are recognized as a viable solution to increase the penetration of renewable energy in bulk power systems. However, they are physically different from synchronous generators in terms of overcurrent capability. To protect the power semiconductor devices and support the power grid under severe symmetrical disturbances, the GFM control systems should be able to achieve the following requirements: current magnitude limitation, fault current contribution, and fault recovery capability. Various current-limiting control methods are reported in the literature to fulfill these goals, including current limiters, virtual impedance, and voltage limiters. This paper presents an overview of those methods. Emerging challenges that need to be addressed, including temporary overcurrent, unspecified output current vector angle, undesired current saturation, and transient overvoltage, are pointed out. Comparative simulations are conducted to demonstrate the performance of different methods under grid voltage drops and phase jumps. Finally, open issues of current-limiting control methods for GFM inverters, including transient stability assessment, voltage source behavior under overcurrent conditions, and windup of voltage controllers, are shared.

7 March 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FZFangzhou Zhao
Fangzhou Zhao
XWXiongfei Wang
Xiongfei Wang
TZTianhua Zhu
Tianhua Zhu
This article proposes a grid-forming based decoupling approach, which effectively mitigates the dynamic interactions between active and reactive power, especially suitable for system stabilization in ultrastrong grids with short-circuit ratio over 30. The physical coupling behaviors are first revealed by analytical studies, where two potential resonances, respectively, located in 40–50 Hz and 0–10 Hz are discovered with mathematical proofs. Based on the results, the decoupling controller is then designed with transfer function approximation for practical usage. The control method not only suppresses the couplings but also cancels two pairs of conjugate poles through decoupling paths. Thanks to the cancellation, the stability margin is remarkably increased in stiff grids, and therefore, a significant bandwidth boost on the power synchronization control can be realized if desired. The experimental results are finally performed to verify the proposed decoupling method.

4 March 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TZTianhua Zhu
Tianhua Zhu
FZFang Zhuo
Fang Zhuo
FZFangzhou Zhao
Fangzhou Zhao
FWFeng Wang
Feng Wang
HYHao Yi
Hao Yi
TZTong Zhao
Tong Zhao
The CLLC resonant converters are drawing more and more attention for their superiority in soft switching, wide output range and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and low efficiency under light-load conditions. Therefore, this paper proposes an optimization for extended phase-shift (EPS) control in full-bridge CLLC resonant converter to improve the light-load efficiency. In order to study the relations between phase-shifts of EPS control and converter efficiency, a detailed circuit model is first established to solve the voltage gain, time-domain expressions of main circuit variables and root mean square (RMS) values of resonant currents. Then, a comprehensive loss evaluation is conducted by calculating and analyzing the main power losses, including conduction loss, switching loss and core losses of magnetic components. Besides, zero voltage switching (ZVS) conditions of primary and rectifier switches are derived to define the range of soft switching. Finally, based on these analyses, the optimal combination of phase-shifts for EPS control is determined to achieve the maximum conversion efficiency of full-bridge CLLC converter at light-load conditions. The validity of the proposed optimized EPS control is verified on a 18~25V/400V, 200W GaN based CLLC resonant converter prototype.

14 July 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
FZFangzhou Zhao
Fangzhou Zhao
XWXiongfei Wang
Xiongfei Wang
ZZZichao Zhou
Zichao Zhou
LHLennart Harnefors
Lennart Harnefors
JSJan Svensson
Jan Svensson
MGMikkel Peter Sidoroff Gryning
Mikkel Peter Sidoroff Gryning
With the increasing deployment of offshore wind power plants (WPPs), the grid-forming (GFM) battery energy storage system (BESS) has recently emerged as an attractive solution to improve the dynamic performances of WPPs. However, the control interactions of the GFM-BESS and offshore WPP, under different grid strengths, tend to complicate the controller-parameter tuning. This paper presents a modeling method for analyzing control interactions of offshore WPP and GFM-BESS, which sheds clear insights into the critical controller parameters to the system dynamics. Differing from conventional methods, a frequency-domain model of GFM-BESS, obtained by taking the Laplace transform of the corresponding state-space model, is developed first. This allows the impedance model of offshore WPP, including a black-box model of long transmission cable, to be flexibly integrated. Based on the model, both closed-loop transfer-function and pole-based dynamic analyses are then performed. Electromagnetic transient simulations corroborate the effectiveness of the model and analysis.

2 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YWYang Wu
Yang Wu
HWHeng Wu
Heng Wu
FZFangzhou Zhao
Fangzhou Zhao
ZLZejie Li
Zejie Li
XWXiongfei Wang
Xiongfei Wang
This letter analyzes the impact of a phase-locked loop (PLL) on small-signal stability in a system of interconnected grid-forming and grid-following (GFL) converters. It identifies an undiscovered instability phenomenon, i.e., the system is prone to unstable when the bandwidth of PLL used with GFL converter is low. Experiments validate the theoretical analysis.

5 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FZFangzhou Zhao
Fangzhou Zhao
TZTianhua Zhu
Tianhua Zhu
ZLZejie Li
Zejie Li
XWXiongfei Wang
Xiongfei Wang
Grid-forming voltage-source converter (GFM-VSC) may experience low-frequency resonances, such as synchronous resonance (SR) and subsynchronous resonance (SSR), in the output power. This article provides a comprehensive study on the low-frequency resonances with GFM-VSC systems and damping control methods. First, the causes of SR and SSR are discussed, highlighting the impacts of control interactions on the resonances. Then, a systematic study of the recent advancements in stabilizing control methods for SR and SSR is presented. Specific physical insights into different damping effects on SR and SSR under weak and stiff grid conditions are revealed and summarized. Furthermore, experimental results comparing the dynamic performances of different damping controls are provided, corroborating the insights obtained in this study. Finally, perspectives on future research trends are shared.