Vajendra Kumar

Vajendra Kumar

Auto-generated profile, based on publicly available information

Vajendra Kumar

Indian Institute of Technology, Roorkee, India

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
PBPallav Kumar Bera
Pallav Kumar Bera
VKVajendra Kumar
Vajendra Kumar
SPSamita Rani Pani
Samita Rani Pani
OMOm Malik
Om Malik
Protective relays can mal-operate for transmission lines connected to doubly fed induction generator (DFIG) based large capacity wind farms (WFs). The performance of distance relays protecting such lines is investigated and a statistical model based intelligent protection of the area between the grid and the WF is proposed in this article. The suggested method employs an adaptive fuzzy inference system to detect faults based on autoregressive (AR) coefficients of the 3-phase currents selected using minimum redundancy maximum relevance algorithm. Deep learning networks are used to supervise the detection of faults, their subsequent localization, and classification. The effectiveness of the scheme is evaluated on IEEE 9-bus and IEEE 39-bus systems with varying fault resistances, fault inception times, locations, fault types, wind speeds, and transformer connections. Further, the impact of factors like the presence of type-4 WFs, double circuit lines, WF capacity, grid strength, FACTs devices, reclosing on permanent faults, power swings, fault during power swings, voltage instability, load encroachment, high impedance faults, evolving and cross-country faults, close-in and remote-end faults, CT saturation, sampling rate, data window size, synchronization error, noise, and semi-supervised learning are considered while validating the proposed scheme. The results show the efficacy of the suggested method in dealing with various system conditions and configurations while protecting the transmission lines that are connected to WFs.

29 July 2020 in IEEE Systems Journal
Verified
Journal Article
Closed access
PBPallav Kumar Bera
Pallav Kumar Bera
CICan Isik
Can Isik
VKVajendra Kumar
Vajendra Kumar
This article solves the problem of accurate detection of internal faults and classification of transients in a five-bus interconnected system for phase angle regulators (PARs) and power transformers (PTs). The analysis prevents mal-operation of differential relays in case of transients other than faults, which include magnetizing inrush, sympathetic inrush, external faults with current transformer (CT) saturation, capacitor switching, nonlinear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of three-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (PT, PAR series, or exciting unit) and identify the type of fault. In case, a transient disturbance is detected, another GBC classifies them into the six disturbances. Five most relevant frequency- and time-domain features obtained using information gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy ( $\bar{\eta }$ ) of 99.95%. The faulty transformer unit is located with $\bar{\eta }$ of 99.5% and the different transient disturbances are identified with $\bar{\eta }$ of 99.3%. Moreover, the reliability of the scheme is verified for different ratings and connections of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two- and three-winding transformer models for creating the internal faults including interturn and interwinding faults.

18 June 2020 in arXiv
Verified
Preprint
Open access
PDF file
SPSamita Rani Pani
Samita Rani Pani
PBPallav Kumar Bera
Pallav Kumar Bera
VKVajendra Kumar
Vajendra Kumar
This paper proposes a Decision Tree (DT) based detection and classification of internal faults in a power transformer. The faults are simulated in Power System Computer Aided Design (PSCAD)/ Electromagnetic Transients including DC (EMTDC) by varying the fault resistance, fault inception angle, and percentage of winding under fault. A series of features are extracted from the differential currents in phases a, b, and c belonging to the time, and frequency domains. Out of these, three features are selected to distinguish the internal faults from the magnetizing inrush and another three to classify faults in the primary and secondary of the transformer. DT, Random Forest (RF), and Gradient Boost (GB) classifiers are used to determine the fault types. The results show that DT detects faults with 100\% accuracy and the GB classifier performed the best among the three classifiers while classifying the internal faults.

4 November 2022 in arXiv
Verified
Preprint
Open access
PDF file
PBPallav Kumar Bera
Pallav Kumar Bera
VKVajendra Kumar
Vajendra Kumar
SPSamita Rani Pani
Samita Rani Pani
VBVivek Bargate
Vivek Bargate
This article presents differential protection of the distribution line connecting a wind farm in a microgrid. Machine Learning (ML) based models are built using differential features extracted from currents at both ends of the line to assist in relaying decisions. Wavelet coefficients obtained after feature selection from an extensive list of features are used to train the classifiers. Internal faults are distinguished from external faults with CT saturation. The internal faults include the high impedance faults (HIFs) which have very low currents and test the dependability of the conventional relays. The faults are simulated in a 5-bus system in PSCAD/EMTDC. The results show that ML-based models can effectively distinguish faults and other transients and help maintain security and dependability of the microgrid operation.

2 August 2020 in arXiv
Verified
Preprint
Open access
PDF file
PBPallav Kumar Bera
Pallav Kumar Bera
CICan Isik
Can Isik
VKVajendra Kumar
Vajendra Kumar
This study solves the problem of accurate detection of internal faults and classification of transients in a 5-bus interconnected system for Phase Angle Regulators (PAR) and Power Transformers. The analysis prevents mal-operation of differential relays in case of transients other than faults which include magnetizing inrush, sympathetic inrush, external faults with CT saturation, capacitor switching, non-linear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of 3-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (Power Transformer, PAR series, or exciting unit) and identify the type of fault. In case a transient disturbance is detected, another GBC classifies them into the six transient disturbances. Five most relevant frequency and time domain features obtained using Information Gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy of 99.95%. The faulty transformer unit is located with a balanced accuracy of 99.5% and the different transient disturbances are identified with a balanced accuracy of 99.3%. Moreover, the reliability of the scheme is verified for different rating and connection of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two and three-winding transformer models for creating the internal faults including inter-turn and inter-winding faults.