Pallav Kumar Bera

Pallav Kumar Bera

Auto-generated profile, based on publicly available information

Pallav Kumar Bera

School of Applied Science and Engineering Western, Kentucky University, Bowling Green, Kentucky, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
SMSubodh Kumar Mohanty
Subodh Kumar Mohanty
PNParesh Kumar Nayak
Paresh Kumar Nayak
PBPallav Kumar Bera
Pallav Kumar Bera
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
The electricity generated from the present-day large capacity doubly fed induction generator (DFIG) installed wind farm is generally transmitted to utility grid via medium or high voltage transmission line (TL). Due to the restriction of building new TLs, series compensated TLs are some cases preferred for such applications. But, the nonlinear output power versus wind speed relation, control strategies of power electronic interfaced DFIG-wind turbine generators and the nonlinear operation of the thyristor-controlled series capacitor (TCSC) during fault impose adverse impact on the performance of the conventionally used distance relaying-based TL protection schemes. In this article, an improved fault detection and classification technique is proposed to assist distance relay in ensuring fast and reliable protection to TCSC compensated TL linked to DFIG-installed wind farm. In this method, a feature called transient monitoring indexed (TMI) is derived from the measured three-phase currents at the relay location for fault detection and TMI-assisted support vector machine is employed further for fault classification. Performance of the proposed scheme is validated on various fault and nonfault transients simulated on a test power system through MATLAB/Simulink. This protective scheme is farther validated throughout real-time assembled dSPACE DS 1104 control prototype hardware. The superiority of the proposed method is also demonstrated through comparative assessment results with few existing techniques. The overall results justify the merits of the proposed method for fast and accurate detection and classification of faults in such crucial TLs.

4 October 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
PBPallav Kumar Bera
Pallav Kumar Bera
VKVajendra Kumar
Vajendra Kumar
SPSamita Rani Pani
Samita Rani Pani
OMOm Malik
Om Malik
Protective relays can mal-operate for transmission lines connected to doubly fed induction generator (DFIG) based large capacity wind farms (WFs). The performance of distance relays protecting such lines is investigated and a statistical model based intelligent protection of the area between the grid and the WF is proposed in this article. The suggested method employs an adaptive fuzzy inference system to detect faults based on autoregressive (AR) coefficients of the 3-phase currents selected using minimum redundancy maximum relevance algorithm. Deep learning networks are used to supervise the detection of faults, their subsequent localization, and classification. The effectiveness of the scheme is evaluated on IEEE 9-bus and IEEE 39-bus systems with varying fault resistances, fault inception times, locations, fault types, wind speeds, and transformer connections. Further, the impact of factors like the presence of type-4 WFs, double circuit lines, WF capacity, grid strength, FACTs devices, reclosing on permanent faults, power swings, fault during power swings, voltage instability, load encroachment, high impedance faults, evolving and cross-country faults, close-in and remote-end faults, CT saturation, sampling rate, data window size, synchronization error, noise, and semi-supervised learning are considered while validating the proposed scheme. The results show the efficacy of the suggested method in dealing with various system conditions and configurations while protecting the transmission lines that are connected to WFs.

29 July 2020 in IEEE Systems Journal
Verified
Journal Article
Closed access
PBPallav Kumar Bera
Pallav Kumar Bera
CICan Isik
Can Isik
VKVajendra Kumar
Vajendra Kumar
This article solves the problem of accurate detection of internal faults and classification of transients in a five-bus interconnected system for phase angle regulators (PARs) and power transformers (PTs). The analysis prevents mal-operation of differential relays in case of transients other than faults, which include magnetizing inrush, sympathetic inrush, external faults with current transformer (CT) saturation, capacitor switching, nonlinear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of three-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (PT, PAR series, or exciting unit) and identify the type of fault. In case, a transient disturbance is detected, another GBC classifies them into the six disturbances. Five most relevant frequency- and time-domain features obtained using information gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy ( $\bar{\eta }$ ) of 99.95%. The faulty transformer unit is located with $\bar{\eta }$ of 99.5% and the different transient disturbances are identified with $\bar{\eta }$ of 99.3%. Moreover, the reliability of the scheme is verified for different ratings and connections of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two- and three-winding transformer models for creating the internal faults including interturn and interwinding faults.

1 June 2023 in International Journal of Cognitive Computing in Engineering
Verified
Journal Article
Open access
SSShashank Singh
Shashank Singh
VAVeena Anand
Veena Anand
PBPallav Kumar Bera
Pallav Kumar Bera

27 August 2024 in Electric Power Systems Research
Verified
Journal Article
Closed access
PBPallav Kumar Bera
Pallav Kumar Bera
SPSamita Rani Pani
Samita Rani Pani
CICan Isik
Can Isik
RBRamesh C. Bansal
Ramesh C. Bansal

17 May 2021 in IEEE Access
Verified
Journal Article
Open access
PBPallav Kumar Bera
Pallav Kumar Bera
CICan Isik
Can Isik
Several conventional and non-conventional transient conditions cause differential relays associated with Phase Angle Regulators to malfunction. For Two-core Symmetric Phase Angle Regulators, this article investigates the suitability of time and time-frequency feature-based estimators to differentiate internal faults from other transient conditions such as overexcitation, external faults with current transformer (CT) saturation, and magnetizing inrush. Subsequently, the faulty core unit (series or exciting) is located, and the transients are identified. Six well-known classifiers are trained on features extracted from one-cycle of post transient 3-phase differential currents filtered by an event detector. Maximum Relevance Minimum Redundancy, Random Forest, and exhaustive search with Decision Trees are used to select the relevant wavelet energy, time-domain, and wavelet coefficient features respectively. The fault detection scheme trained on XGBoost classifier with hyperparameters obtained from Bayesian Optimization gives an accuracy of 99.8%. The reliability of the proposed scheme is verified with varying tap positions, noise levels, and transformer ratings; and under different conditions like CT saturation, fault during magnetizing inrush, series core saturation, low current faults, and integration of wind energy. As a potential application, the methodology can be deployed to supervise microprocessor-based differential relays to improve the security and dependability of the protection system.