19 February 2018 in IEEE Transactions on Power Systems
Chance constrained optimal power flow (OPF) has been recognized as a promising framework to manage the risk from variable renewable energy (VRE). In the presence of VRE uncertainties, this paper discusses a distributionally robust chance constrained approximate ac-OPF. The power flow model employed in the proposed OPF formulation combines an exact ac power flow model at the nominal operation point and an approximate linear power flow model to reflect the system response under uncertainties. The ambiguity set employed in the distributionally robust formulation is the Wasserstein ball centered at the empirical distribution. The proposed OPF model minimizes the expectation of the quadratic cost function w.r.t. the worst-case probability distribution and guarantees the chance constraints satisfied for any distribution in the ambiguity set. The whole method is data-driven in the sense that the ambiguity set is constructed from historical data without any presumption on the type of the probability distribution, and more data leads to smaller ambiguity set and less conservative strategy. Moreover, special problem structures of the proposed problem formulation are exploited to develop an efficient and scalable solution approach. Case studies are carried out on the IEEE 14 and 118 bus systems to show the accuracy and necessity of the approximate ac model and the attractive features of the distributionally robust optimization approach compared with other methods to deal with uncertainties.
18 August 2017 in IEEE Transactions on Power Systems
This paper proposes a data-driven affinely adjustable distributionally robust method for unit commitment considering uncertain load and renewable generation forecasting errors. The proposed formulation minimizes expected total operation costs, including the costs of generation, reserve, wind curtailment, and load shedding, while guaranteeing the system security. Without any presumption about the probability distribution of the uncertainties, the proposed method constructs an ambiguity set of distributions using historical data and immunizes the operation strategies against the worst case distribution in the ambiguity set. The more historical data is available, the smaller the ambiguity set is and the less conservative the solution is. The formulation is finally cast into a mixed integer linear programming whose scale remains unchanged as the amount of historical data increases. Numerical results and Monte Carlo simulations on the 118- and 1888-bus systems demonstrate the favorable features of the proposed method.
9 November 2017 in IEEE Transactions on Industrial Informatics
This paper proposes distributionally robust energy-reserve-storage co-dispatch model and method to facilitate the integration of variable and uncertain renewable energy. The uncertainties of renewable generation forecasting errors are characterized through an ambiguity set which is a set of probability distributions consistent with observed historical data. The proposed model minimizes the expected operation costs corresponding to the worst-case distribution in the ambiguity set. Distributionally robust chance constraints are employed to guarantee reserve and transmission adequacy. The more historical data is available, the smaller the ambiguity set is and the less conservative the solution is. The formulation is finally cast into a mixed integer linear programming whose scale remains unchanged as the amount of historical data increases. Inactive constraint identification and convex relaxation techniques are introduced to reduce the computational burden. Numerical results and Monte Carlo simulations on IEEE 118-bus systems demonstrate the effectiveness and efficiency of the propose method.
18 October 2015 in Mathematical Problems in Engineering
As using the classical quasi-steady state (QSS) model could not be able to accurately simulate the dynamic characteristics of DC transmission and its controlling systems in electromechanical transient stability simulation, when asymmetric fault occurs in AC system, a modified quasi-steady state model (MQSS) is proposed. The model firstly analyzes the calculation error induced by classical QSS model under asymmetric commutation voltage, which is mainly caused by the commutation voltage zero offset thus making inaccurate calculation of the average DC voltage and the inverter extinction advance angle. The new MQSS model calculates the average DC voltage according to the actual half-cycle voltage waveform on the DC terminal after fault occurrence, and the extinction advance angle is also derived accordingly, so as to avoid the negative effect of the asymmetric commutation voltage. Simulation experiments show that the new MQSS model proposed in this paper has higher simulation precision than the classical QSS model when asymmetric fault occurs in the AC system, by comparing both of them with the results of detailed electromagnetic transient (EMT) model of the DC transmission and its controlling system.