Xiang Ji

Xiang Ji

Auto-generated profile, based on publicly available information

Xiang Ji

Key Laboratory of Intelligent Optical Sensing and Manipulation, and Engineering Research Center for Precision Photonics Integration & System Applications, Ministry of Education, Nanjing University, Nanjing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
KTKaifei Tang
Kaifei Tang
JWJiantao Wang
Jiantao Wang
WXWenqu Xu
Wenqu Xu
XJXiang Ji
Xiang Ji
JLJiahui Liu
Jiahui Liu
WJWei Jiang
Wei Jiang
With the explosive growth of data, tensor processing has emerged as a pivotal component of the next generation of artificial intelligence (AI) algorithms. Current photonic convolutional processors transform tensor convolutions into multi-channel general matrix multiplication (GeMM), which follows the path of electronic counterparts, leading to data replication and hardware complexity. In this study, we experimentally and theoretically demonstrate a photonic tensor processing unit (PTPU) with a single modulator, which offers a more concise approach for multi-channel standard tensor convolution processing, different from the channel-wise convolution method. By executing multi-tensor parallel computing instead of multi-channel parallel computing, PTPU can directly produce feature tensors without clock synchronization and delay compensation between multiple channels and allows more release of physical hardware resources. Furthermore, an integrated array of semiconductor optical amplifiers (SOAs) are used to be photonic synapses for programmable weight bank, demonstrating record-high precision of 9.2 bits for weights. In the proof-of-concept experiment, we extracted features from a 3-channel (RGB) image in horizontal and vertical directions, using integrated multi-wavelength photonic tensor kernels. We then built a 3D convolutional neural network to predict the presence of COVID-19 based on computer tomography (CT) scan data consisting of 64-channel tensors.

24 February 2024 in Photonics
Verified
Journal Article
Open access
PDF file
QLQuan Luo
Quan Luo
HLHongsheng Luo
Hongsheng Luo
GWGuihan Wu
Guihan Wu
XJXiang Ji
Xiang Ji
JSJinshan Su
Jinshan Su
WJWei Jiang
Wei Jiang
Laser remote sensing of earthquake waves has the potential to be used in many applications. This article shows a Doppler model for laser remote sensing of seismic waves based on a wavefront sensor. The longitudinal vibration wave is analyzed using remote sensing, guided by theoretical principles. To determine the magnitude of ground vibration, we employ the method of wavefront phase change analysis, utilizing a continuous laser emitting light with a wavelength of 635 nm to illuminate the ground target. The ground vibration amplitude within the range of 0.12–1.18 mm was examined, confirming the reasonableness of the Doppler model. Simultaneously, the experimental findings indicate that the system exhibits a certain enhancement in detection accuracy compared to the conventional laser remote sensing detection technique. This approach can detect vibration signals at a sub-millimeter scale level, with an accuracy of 1% to 2%. The approach can fulfill the requirements for detecting seismic waves with low frequencies.

20 February 2025 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
FYFuhao Yu
Fuhao Yu
ZZzhaobang zeng
zhaobang zeng
KTKaifei Tang
Kaifei Tang
SYShichong Yang
Shichong Yang
XJXiang Ji
Xiang Ji
WJWei Jiang
Wei Jiang
Micro-ring modulators with a small footprint and energy consumption have been explored for densely integrated high throughput optical interconnects. However, their strong dispersive response results in frequency chirp and pulse broadening, which limits their signal transmission distance. Here we explore the low chirp operation of a dual-racetrack modulator symmetrically coupled to a bus waveguide. With opposite index changes in the two resonators, the coherent couplings of two resonators' optical fields with the bus waveguide and their interference can cancel out the output phase variation due to a single resonator. This allows the push-pull operation to achieve a lower chirp compared to the single-drive operation. The advantage of lower chirp operation is experimentally verified through open eye diagram with 100 Gbps PAM-4 transmitted over 2 km single-mode fiber (SMF), with a peak-to-peak driving voltage of 1.6 V.

4 November 2023
Verified
Conference Paper
Closed access
KTKaifei Tang
Kaifei Tang
JWJiantao Wang
Jiantao Wang
XJXiang Ji
Xiang Ji
JLJiahui Liu
Jiahui Liu
YXYu Xin
Yu Xin
WJWei Jiang
Wei Jiang
Current photonic convolutional processors transform tensor convolutions into multi-channel general matrix multiplication (GeMM), leading to data replication and hardware complexity. In this study, we propose and experimentally demonstrate a photonic tensor processing unit (PTPU) with single dataflow, which offers a more concise approach to multi-channel standard tensor convolution processing. In experiment, we extracted features from a 3-channel (RGB) image in horizontal and vertical directions using an integrated multi-wavelength source. We then built a $3\mathrm{D}$ -convolutional neural network to predict the presence of COVID-19 based on computer tomography (CT) scan data consisting of 64-channel tensors.