In the past decades, numerous surgical robotic systems have been developed to improve dexterity, precision, and ergonomics in minimally invasive surgery (MIS). These robotic systems usually have different forms to accommodate the requirements from either multiport or single-port procedures. Unlike the design consensus in the multiport systems where distal-wristed and straight-stemmed instruments are maneuvered by patient-side manipulators, different approaches are still being explored to verify the fulfillment of the clinical and functional requirements from single-port procedures. No systems have been shown to satisfactorily handle both the multiport and the single-port procedures. Utilizing the previously proposed dual continuum mechanism to realize a payload-enhanced multidegree of freedom surgical instrument with a tight bending wrist for intra-abdomen dexterity, it was found that the locations and the number of channels of the access ports can be freely configured. A modular surgical robotic platform is, hence, proposed for handling multiport, single-port, and for the first time hybrid-port procedures. The design concepts, system descriptions, teleoperation kinematics, experimental characterizations, and animal studies are reported. It is expected that suitable invasiveness , where a minimal number of skin incisions can always be used to treat a condition, is to be achieved by the proposed system. True potentials of the proposed system are to be verified in the coming larger scale animal studies and clinical trials.
10 July 2019 in IEEE Robotics and Automation Letters
Robot-assisted laparoscopic minimally invasive surgery has gained significant attentions due to its enhanced dexterity, improved precision, natural eye-hand coordination, etc. In these procedures, stick-like surgical tools with distal wrists are usually maneuvered by multiple patient-side manipulators to perform an operation. These patient-side manipulators shall realize remote center of motion movements and are subject to risks of mutual collisions during motion. On the other hand, the continuum surgical manipulators, often with multiple segments, usually have several degrees of freedom (DoFs) for the movements in a patient's cavity, and only need a lockable bedside stand, rather than a manipulator. However, the continuum segments inherently have limited bending curvature such that large orientation changes of the surgical end effector around confined anatomical features can be challenging. This letter, hence, proposes a modular continuum-articulated laparoscopic robotic tool design with simple and decoupled kinematics. An inverted dual-continuum mechanism is used in the tool to realize pure translations, while a 2-DoF cable-driven distal wrist is incorporated for orientations. The utilized dual-continuum mechanism maintains a constant length across its entire cross section to significantly facilitate maintaining tensions for the actuation cables of the distal wrist. Design concept, kinematics, system descriptions, actuation calibration, and experimental characterizations are reported, demonstrating effectiveness of the proposed idea.
15 July 2019 in IEEE Robotics and Automation Letters
The use of continuum manipulators in surgical applications has increased recently. A continuum surgical manipulator is usually teleoperated after it is fully inserted into a patient's cavity. Clearly, it is still possible to control the continuum surgical manipulator while it is not fully inserted, although the mobility might be reduced under its partially-inserted configurations. However, such a control scheme for realizing the configuration transition during the manipulator's gradual insertion is missing. This letter, hence, proposes a novel kinematic framework of controlling a continuum surgical manipulator with configuration transitions for improved kinematic performance in teleoperation. The kinematic framework includes prioritized formulation of the Jacobian-based inverse kinematics, prediction-based constraint imposition and a set of configuration transition strategies. Both numerical simulations and experimental investigations were carried out to validate the proposed idea.
Reliable three-dimensional shape feedback is essential for magnetic soft continuum robots (MSCRs) to navigate safely within highly confined and tortuous vascular pathways. Fiber Bragg grating (FBG) sensors provide a promising solution to this issue, due to their compact form, high sensitivity, and immunity to electromagnetic interference. However, the low elastic modulus of MSCRs leads to substantial strain-transfer loss between the robot body and the embedded FBGs. Meanwhile, the large-curvature bending and torsional deformation introduce significant errors in curvature and bending-direction estimation. To overcome these challenges, this work introduces a compact and cost-effective shape-sensing scheme by using sparse FBG arrays with an optimized curvature/angle estimation algorithm, to realize robust 3D shape reconstruction. A curvature correction coefficient and a twist-angle offset are used to compensate for material-dependent transfer and alignment errors, while a curvature-pair interpolation algorithm, tailored for C2 continuous spatial curves, enables accurate curvature/angle estimation at non-sensing locations and improves the MSCR’s shape reconstruction accuracy. Experimental calibration and validation demonstrate that the proposed scheme can achieve submillimeter-level shape reconstruction and millimeter-scale tip positioning precision, satisfying the clinical requirements for minimally invasive interventions.
12 April 2026 in Sensors and Actuators A: Physical