Multi-backbone continuum robots demonstrated potentials for dexterous manipulation with proper payload capability in minimally invasive surgeries. Most prior works assume constant curvature shapes of the continuum segments in the modeling and control of the multi-backbone continuum robots. The actuation coupling effects between adjacent continuum segments and the segments' variable curvature shapes under environmental interactions have not been fully addressed by a static-kinematic model specifically for multi-backbone continuum robots. This letter hence proposes a variable curvature model for multi-backbone continuum robots with relatively low bending curvature based on the Cosserat rod theory. The model focuses on the major factors that affect the robot's shape: the length-prescribed push-pull actuation, the elastic elongation of the backbone rods, and the external loads. With five assumptions made to simplify the constraints in the multi-backbone continuum robot, a compact statics-kinematics formulation is derived with computational performance acceptable for real-time control. Experiments were conducted on a continuum robotic system to quantify the modeling accuracy and computational efficiency. The proposed model was shown to have substantially improved accuracy over the constant curvature model. The average computational time for solving the inverse kinematics was 0.7ms on a 2.6 GHz Intel i7-5600U platform, which is promising for real-time control.
24 September 2021 in IEEE/ASME Transactions on Mechatronics
In the past decades, numerous surgical robotic systems have been developed to improve dexterity, precision, and ergonomics in minimally invasive surgery (MIS). These robotic systems usually have different forms to accommodate the requirements from either multiport or single-port procedures. Unlike the design consensus in the multiport systems where distal-wristed and straight-stemmed instruments are maneuvered by patient-side manipulators, different approaches are still being explored to verify the fulfillment of the clinical and functional requirements from single-port procedures. No systems have been shown to satisfactorily handle both the multiport and the single-port procedures. Utilizing the previously proposed dual continuum mechanism to realize a payload-enhanced multidegree of freedom surgical instrument with a tight bending wrist for intra-abdomen dexterity, it was found that the locations and the number of channels of the access ports can be freely configured. A modular surgical robotic platform is, hence, proposed for handling multiport, single-port, and for the first time hybrid-port procedures. The design concepts, system descriptions, teleoperation kinematics, experimental characterizations, and animal studies are reported. It is expected that suitable invasiveness , where a minimal number of skin incisions can always be used to treat a condition, is to be achieved by the proposed system. True potentials of the proposed system are to be verified in the coming larger scale animal studies and clinical trials.