21 August 2023 in IEEE Transactions on Instrumentation and Measurement
The image quality of C-arm CT degrades due to the non-ideal projection geometry due to mechanical vibrations of the gantry during the CT scan; therefore, geometrical calibration methods need to be applied to derive the view-specific projection matrices, which are incorporated in the reconstruction processes. Previous geometrical calibration methods either requires specific calibration phantoms or long computational time due to the 3D-2D registration process. This work begins with a theoretical derivation on how the perturbed geometrical parameters impact the projection images. It was found that with small perturbations of the view angle and the altitude angle, the relationship between the projection images under the ideal geometry and those under the perturbed geometry can be related based on a model-based 2D deformation dependent on the perturbed geometrical parameters. Guided by the theoretical derivations, a new geometrical correction method was proposed which generates the geometrical parameters based on 2D-2D registrations between the ideal projection images and the perturbed projection images. The proposed method was applied to offline and online calibration and was validated by both numerical experiments and physical experiments.
4 August 2022 in RSC Advances
Enzymatic synthesis of selenium (Se)-enriched peptides is vital for their application in supplementing organic Se. However, the poor stability and reusability of the free enzyme impedes the reaction. In this work, a highly stable immobilized Alcalase was synthesized by immobilizing Alcalase on tannic acid (TA) and polyethyleneimine (PEI) modified Fe3O4 nanoparticles (NPs). The optimal immobilization conditions for immobilized Alcalase were found at a TA/PEI (v/v) ratio of 1 : 1, pH of 10, and temperature of 40 °C, and the results from scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier Transform Infrared (FTIR) and X-ray photoelectron spectroscopy (XPS) characterization confirmed the successful immobilization of Alcalase. The results of an enzyme property test showed that immobilized Alcalase had higher thermal and pH stability than free Alcalase, and retained 61.0% of the initial enzyme activity after 10 repetitions. Furthermore, the organic Se content of Se-enriched peptide prepared through enzymatic hydrolysis of Cardamine violifolia (CV) protein with immobilized Alcalase was 2914 mg kg−1, and the molecular weight was mainly concentrated in 924.4 Da with complete amino acid components. Therefore, this study proposes the feasibility of immobilized enzymes for the production of Se-enriched peptides.
16 February 2024 in IEEE Journal of Biomedical and Health Informatics
Spectral CT can provide material characterization ability to offer more precise material information for diagnosis purposes. However, the material decomposition process generally leads to amplification of noise which significantly limits the utility of the material basis images. To mitigate such problem, an image domain noise suppression method was proposed in this work. The method performs basis transformation of the material basis images based on a singular value decomposition. The noise variances of the original spectral CT images were incorporated in the matrix to be decomposed to ensure that the transformed basis images are statistically uncorrelated. Due to the difference in noise amplitudes in the transformed basis images, a selective filtering method was proposed with the low-noise transformed basis image as guidance. The method was evaluated using both numerical simulation and real clinical dual-energy CT data. Results demonstrated that compared with existing methods, the proposed method performs better in preserving the spatial resolution and the soft tissue contrast while suppressing the image noise. The proposed method is also computationally efficient and can realize real-time noise suppression for clinical spectral CT images.
12 June 2024 in IEEE Transactions on Instrumentation and Measurement
Dual-energy computed tomography (DECT) plays a crucial role in clinical practice due to its capabilities in material identification and quantification. However, complete DECT scans expose patients to additional radiation. To mitigate such a problem, one method is to reduce the CT scan angular range, which may cause limited-angle artifacts. This work utilized Multi-stage dual-domain networks (MsDu-Nets) for dual-energy limited-angle reconstruction that only requires a 180-degree scan. MsDu-Nets consists of multiple stages, where data processing is performed in both the sinogram domain and image domain within each stage. A filtered back projection (FBP) module is used to connect these two domains. MsDu-Nets leveraged the informative prior obtained by directly concatenating the dual-energy projection data, and directly reconstructing it after applying Parker Weights, which helps the network focus more on anatomical information. Self-augmentation is also employed to mitigate the streak artifacts introduced by the informative prior and enables the transmission of original information across stages. Comparison experiments and material decomposition experiments demonstrate that the proposed method is capable of obtaining high-quality dual-energy reconstructed images. The ablation experiments also validate the roles of different modules or components of the method.