Hongting Zhao

Hongting Zhao

Auto-generated profile, based on publicly available information

Hongting Zhao

Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2023 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
HZHongting Zhao
Hongting Zhao
ESEashani Sathialingam
Eashani Sathialingam
KCKyle R. Cowdrick
Kyle R. Cowdrick
TUTara Urner
Tara Urner
SLSeung Yup Lee
Seung Yup Lee
EBErin Buckley
Erin Buckley
Diffuse correlation spectroscopy (DCS) is a low-cost, non-invasive optical technology for measuring blood flow. DCS measures the temporal intensity autocorrelation (g2(τ)) of multiply scattered light that has traveled from the source to the tissue surface. The decay rate of this curve is related to the motion of red blood cells in the underlying tissue.1,2 Correlation diffusion theory is used to estimate an index of blood flow (cm2/s) from g2(τ). When DCS is applied in the brain, detected photons that carry information about cerebral hemodynamics have also interacted with extracerebral layers (i.e., skull, scalp, and cerebral spinal fluid) by the nature of the non-invasive measurement. Thus, signal contamination from extracerebral layers is a challenge with DCS.3,4

23 May 2024 in Blood
Verified
Journal Article
Open access
PDF file
RBRowan O. Brothers
Rowan O. Brothers
KTKatherine B. Turrentine
Katherine B. Turrentine
MAMariam Akbar
Mariam Akbar
STSydney Triplett
Sydney Triplett
HZHongting Zhao
Hongting Zhao
EBErin Buckley
Erin Buckley
Voxelotor is an inhibitor of sickle hemoglobin polymerization that is used to treat sickle cell disease. Although voxelotor has been shown to improve anemia, the clinical benefit on the brain remains to be determined. This study quantified the cerebral hemodynamic effects of voxelotor in children with sickle cell anemia (SCA) using noninvasive diffuse optical spectroscopies. Specifically, frequency-domain near-infrared spectroscopy combined with diffuse correlation spectroscopy were used to noninvasively assess regional oxygen extraction fraction (OEF), cerebral blood volume, and an index of cerebral blood flow (CBFi). Estimates of CBFi were first validated against arterial spin–labeled magnetic resonance imaging (ASL-MRI) in 8 children with SCA aged 8 to 18 years. CBFi was significantly positively correlated with ASL-MRI–measured blood flow (R2 = 0.651; P = .015). Next, a single-center, open-label pilot study was completed in 8 children with SCA aged 4 to 17 years on voxelotor, monitored before treatment initiation and at 4, 8, and 12 weeks (NCT05018728). By 4 weeks, both OEF and CBFi significantly decreased, and these decreases persisted to 12 weeks (both P < .05). Decreases in CBFi were significantly correlated with increases in blood hemoglobin (Hb) concentration (P = .025), whereas the correlation between decreases in OEF and increases in Hb trended toward significance (P = .12). Given that previous work has shown that oxygen extraction and blood flow are elevated in pediatric SCA compared with controls, these results suggest that voxelotor may reduce cerebral hemodynamic impairments. This trial was registered at www.ClinicalTrials.gov as #NCT05018728.

1 January 2023 in Neurophotonics
Verified
Journal Article
Open access
PDF file
HZHongting Zhao
Hongting Zhao
EBErin Buckley
Erin Buckley
SignificanceDiffuse correlation spectroscopy (DCS) is an emerging optical modality for non-invasive assessment of an index of regional cerebral blood flow. By the nature of this noninvasive measurement, light must pass through extracerebral layers (i.e., skull, scalp, and cerebral spinal fluid) before detection at the tissue surface. To minimize the contribution of these extracerebral layers to the measured signal, an analytical model has been developed that treats the head as a series of three parallel and infinitely extending slabs (mimicking scalp, skull, and brain). The three-layer model has been shown to provide a significant improvement in cerebral blood flow estimation over the typically used model that treats the head as a bulk homogenous medium. However, the three-layer model is still a gross oversimplification of the head geometry that ignores head curvature, the presence of cerebrospinal fluid (CSF), and heterogeneity in layer thickness.AimDetermine the influence of oversimplifying the head geometry on cerebral blood flow estimated with the three-layer model.ApproachData were simulated with Monte Carlo in a four-layer slab medium and a three-layer sphere medium to isolate the influence of CSF and curvature, respectively. Additionally, simulations were performed on magnetic resonance imaging (MRI) head templates spanning a wide-range of ages. Simulated data were fit to both the homogenous and three-layer model for CBF. Finally, to mitigate the errors in potential CBF estimation due to the difficulty in defining layer thickness, we investigated an approach to identify an equivalent, “optimized” thickness via a pressure modulation.ResultsBoth head curvature and failing to account for CSF lead to significant errors in the estimation of CBF. However, the effect of curvature and CSF on relative changes in CBF is minimal. Further, we found that CBF was underestimated in all MRI-templates, although the magnitude of these underestimations was highly influenced by small variations in the source and detector optode positioning. The optimized thickness obtained from pressure modulation did not improve estimation accuracy of CBF, although it did significantly improve the estimation accuracy of relative changes in CBF.ConclusionsIn sum, these findings suggest that the three-layer model holds promise for improving estimation of relative changes in cerebral blood flow; however, estimations of absolute cerebral blood flow with the approach should be viewed with caution given that it is difficult to account for appreciable sources of error, such as curvature and CSF.

20 July 2026 in The Journal of Pediatrics
Verified
Journal Article
Closed access
HZHongting Zhao
Hongting Zhao
CDCaitlyn Davis
Caitlyn Davis
DADarci Anderson
Darci Anderson
BBBriston Bayle
Briston Bayle
ASAlexis Schulz
Alexis Schulz
Jennifer M. LynchJennifer M. Lynch
Jennifer M. Lynch