Juliana Fernandes Matos

Juliana Fernandes Matos

Auto-generated profile, based on publicly available information

Juliana Fernandes Matos

Biosciences Institute of Botucatu, São Paulo State University, Botucatu, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2017 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
APANDRE GONCALVES Prospero
ANDRE GONCALVES Prospero
CQCaio C. Quini
Caio C. Quini
ABAndris Bakuzis
Andris Bakuzis
PFPatrícia Fidelis-De-Oliveira
Patrícia Fidelis-De-Oliveira
GMGustavo M. Moretto
Gustavo M. Moretto
JMjose Ricardo Arruda Miranda
jose Ricardo Arruda Miranda
We introduce and demonstrate that the AC biosusceptometry (ACB) technique enables real-time monitoring of magnetic nanoparticles (MNPs) in the bloodstream. We present an ACB system as a simple, portable, versatile, non-invasive, and accessible tool to study pharmacokinetic parameters of MNPs, such as circulation time, in real time. We synthesized and monitored manganese doped iron oxide nanoparticles in the bloodstream of Wistar rats using two different injection protocols. Aiming towards a translational approach, we also simultaneously evaluated cardiovascular parameters, including mean arterial pressure, heart rate, and episodes of arrhythmia in order to secure the well-being of all animals. We found that serial injections increased the circulation time compared with single injections. Immediately after each injection, we observed a transitory drop in arterial pressure, a small drop in heart rate, and no episodes of arrhythmia. Although some cardiovascular effects were observed, they were transitory and easily recovered in both protocols. These results indicate that the ACB system may be a valuable tool for in vivo, real-time MNP monitoring that allows associations with other techniques, such as pulsatile arterial pressure and electrocardiogram recordings, helping ensuring the protocol safety, which is a fundamental step towards clinical applications.

1 January 2016 in World Journal of Gastroenterology
Verified
Journal Article
Open access
JMJuliana Fernandes Matos
Juliana Fernandes Matos
MAMadileine Francely Americo
Madileine Francely Americo
YSYuri Karen Sinzato
Yuri Karen Sinzato
GVGustavo Tadeu Volpato
Gustavo Tadeu Volpato
LCLuciana Cora
Luciana Cora
JMJose Ricardo Arruda Miranda
Jose Ricardo Arruda Miranda
AIM: To correlate gastric contractility, gastrointestinal transit, and hormone levels in non-pregnant (estrous cycle) and pregnant rats using noninvasive techniques. METHODS: Female rats (n = 23) were randomly divided into (1) non-pregnant, (contractility, n = 6; transit, n = 6); and (2) pregnant (contractility, n = 5; transit, n = 6). In each estrous cycle phase or at 0, 7, 14, and 20 d after the confirmation of pregnancy, gastrointestinal transit was recorded by AC biosusceptometry (ACB), and gastric contractility was recorded by ACB and electromyography. After each recording, blood samples were obtained for progesterone and estradiol determination. RESULTS: In the estrous cycle, despite fluctuations of sex hormone levels, no significant changes in gastrointestinal motility were observed. Days 7 and 14 of pregnancy were characterized by significant changes in the frequency of contractions (3.90 ± 0.42 cpm and 3.60 ± 0.36 cpm vs 4.33 ± 0.25 cpm) and gastric emptying (168 ± 17 min and 165 ± 15 min vs 113 ± 15 min) compared with day 0. On these same days, progesterone levels significantly increased compared with control (54.23 ± 15.14 ng/mL and 129.96 ± 30.52 ng/mL vs 13.25 ± 6.31 ng/mL). On day 14, we observed the highest level of progesterone and the lowest level of estradiol compared with day 0 (44.3 ± 15.18 pg/mL vs 24.96 ± 5.96 pg/mL). CONCLUSION: Gastrointestinal motility was unaffected by the estrous cycle. In our data, high progesterone and low estradiol levels can be associated with decreased contraction frequency and slow gastric emptying.

25 August 2015 in Neurogastroenterology & Motility
Verified
Journal Article
Closed access
PDF file
MCM. F. F. Calabresi
M. F. F. Calabresi
CQC. C. Quini
C. C. Quini
JMJ. F. Matos
J. F. Matos
GMG. M. Moretto
G. M. Moretto
MAM. F. Americo
M. F. Americo
JMjose Ricardo Arruda Miranda
jose Ricardo Arruda Miranda

1 April 2015 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
CQCaio C. Quini
Caio C. Quini
JMJuliana F. Matos
Juliana F. Matos
APANDRE GONCALVES Prospero
ANDRE GONCALVES Prospero
MCMarcos Felipe F. Calabresi
Marcos Felipe F. Calabresi
NZNicholas Zufelato
Nicholas Zufelato
JMJosé Ricardo A. Miranda
José Ricardo A. Miranda

1 March 2015 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
MMMurillo Martins
Murillo Martins
MCMarcos F. Calabresi
Marcos F. Calabresi
CQCaio Quini
Caio Quini
JMJuliana F. Matos
Juliana F. Matos
JMJosé R.A. Miranda
José R.A. Miranda
Heloisa BordalloHeloisa Bordallo
Heloisa Bordallo

1 April 2015 in Placenta
Verified
Journal Article
Closed access
JMJ.F. Matos
J.F. Matos
JMJ.R.A. Miranda
J.R.A. Miranda
MAM. Américo
M. Américo
YSY.K. Sinzato
Y.K. Sinzato
DDD.C. Damasceno
D.C. Damasceno