Xiangqi Meng

Xiangqi Meng

Auto-generated profile, based on publicly available information

Xiangqi Meng

School of Electric Power, Civil Engineering and Architecture, Shanxi University, Taiyuan, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XMXiangqi Meng
Xiangqi Meng
YJYanbing Jia
Yanbing Jia
Qianwen XuQianwen Xu
Qianwen Xu
CRChunguang Ren
Chunguang Ren
XHXiaoqing Han
Xiaoqing Han
Peng WangPeng Wang
Peng Wang
The stability of dual active bridge converter (DAB) is threatened when feeding the constant power loads (CPLs). This article proposes a deep reinforcement learning-based backstepping control strategy to solve this problem. First, a nonlinear disturbance observer is adopted to estimate the large-signal nonlinear disturbance. Then, a backstepping controller is used to stabilize the voltage response of the DAB under the large-signal disturbance. Finally, a compensation method based on deep reinforcement learning is developed to intelligently minimize output voltage tracking error and improve the operating efficiency of the system. The proposed controller can guarantee system stability under the large-signal disturbance of the CPL and achieve a fast dynamic response with accurate voltage tracking; it is more adaptive by using the deep reinforcement learning technique through the learning of its neural networks. The effectiveness of the proposed controller is verified by experiments.

20 June 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
XMXiangqi Meng
Xiangqi Meng
YJYanbing Jia
Yanbing Jia
CRChunguang Ren
Chunguang Ren
PZPei Zhao
Pei Zhao
XHXiaoqing Han
Xiaoqing Han
Peng WangPeng Wang
Peng Wang
The DC solid-state transformer (DCSST) is a key component of the DC microgrid, and stability issues due to operation with constant power loads (CPLs) have become increasingly prominent. To stabilize the system of DCSST with CPLs, in this paper, a novel intelligent backstepping controller based on a nonlinear disturbance observer (NDO) is proposed, and the control coefficients of the backstepping control are automatically adjusted by an auxiliary deep deterministic policy gradient (DDPG) controller. More specifically, the NDO estimates the large-signal nonlinear disturbance of the load power variation, and a backstepping controller is designed to improve the stability of the system under the estimated large-signal disturbance. Then, an input voltage equalizing compensator is added to ensure the identical input voltage to each sub-module of DCSST. Furthermore, a DDPG sub-controller is introduced into the backstepping control to intelligently adjust the control coefficients to improve the operating efficiency of the system. The results of the simulation and experiment show that the system is more robust due to the learning ability of the proposed controller, and the proposed controller can improve the stability of the system under the large-signal disturbance and intelligently ensure fast dynamic response with accurate tracking over different operating environments.

24 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XMXiangqi Meng
Xiangqi Meng
YJYanbing Jia
Yanbing Jia
CRChunguang Ren
Chunguang Ren
XHXiaoqing Han
Xiaoqing Han
Peng WangPeng Wang
Peng Wang
This article proposes a circulating current and second harmonic current (SHC) suppression method by introducing virtual impedance into the circulating current and output current feedback control loops of the dc solid-state transformer (DCSST). The virtual impedance is employed to adjust impedance in the circulating current feedback control loop to decrease the circulating current when the transmission efficiency of each dual active bridge is different. And a SHC suppression method, which introduces the virtual impedance containing a bandpass filter, is adopted to reduce the SHC and improve the dynamic performance of the DCSST. Moreover, a relatively independent modular control method, which is conducive to the modular expansion of the DCSST, is proposed. Compared with traditional DCSST control methods, the proposed method can simultaneously realize the output current sharing and effectively reduce the SHC with modular control. Finally, a DCSST prototype is built and the results of the experiment verify the validity and effectiveness of the proposed control strategy and solutions.

30 April 2026 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
XMXiangqi Meng
Xiangqi Meng
PZPei Zhao
Pei Zhao
CRChunguang Ren
Chunguang Ren
XHXiaoqing Han
Xiaoqing Han
Peng WangPeng Wang
Peng Wang
To address the challenges of controlling a dual active bridge (DAB) converter under nonlinear loads that cannot be accurately modeled, this paper proposes a hybrid control method combining deep reinforcement learning (DRL) and ultra-local model-free control (ULMC). The proposed approach eliminates the need for precise mathematical models, ensures accurate regulation of the DAB under nonlinear loads and large disturbances, and enhances system adaptability. First, a model free Kalman filter (MFKF) is developed to filter out noise and estimate uncertain disturbances. Next, the ULMC is designed to ensure system stability without relying on an accurate model of the system, even under large-signal disturbances. Finally, a DRL-based sub-controller using proximal policy optimization (PPO) is designed, which is capable of learning robust and risk-sensitive control policies under model uncertainty and large disturbances. Moreover, the PPO-based sub-controller is integrated into the ULMC to intelligently adjust the control parameter, further improving adaptability and performance. The experimental results demonstrate that the proposed control method can adaptively maintain the stability of the system under large signal disturbance without requiring an accurate model, and achieve excellent dynamic and steady-state performance.

1 July 2019
Verified
Conference Paper
Closed access
SLShengwen Li
Shengwen Li
XMXiangqi Meng
Xiangqi Meng
XHXiaoqing Han
Xiaoqing Han
PWPeng Wang
Peng Wang
YJYanbing Jia
Yanbing Jia
CRChunguang Ren
Chunguang Ren
Aiming at the poor dynamic performance of DC solid transformer with dual-loop control, a three-loop control method is proposed for the DC transformer to improve the system dynamic performance. The proposed control method is implemented by introducing an output current loop to the traditional dual-loop control system. Simulation results show the effective of the proposed method.

23 October 2025 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
XMXiangqi Meng
Xiangqi Meng
YJYanbing Jia
Yanbing Jia
CRChunguang Ren
Chunguang Ren
PZPei Zhao
Pei Zhao
JLJingkuan Li
Jingkuan Li
Peng WangPeng Wang
Peng Wang
The DC solid-state transformer (DCSST) serves as a key component for connecting power supplies, loads, and other elements in a DC microgrid system. With the integration of new energy sources and random loads, the system has become increasingly complex, making accurate modeling challenging due to high modeling costs. The randomness of the loads introduces various disturbances, compromising system stability. To address these challenges, this paper proposes a data-driven model-free control (DMFC) approach based on deep reinforcement learning (DRL) and an improved Kalman filter (IKF) for the DCSST. First, a data-driven model of the DCSST is established. Next, the IKF is designed, which is tailored for DMFC to correct measurement errors, filter noise, and estimate uncertain disturbances. Subsequently, the DMFC is introduced, which ensures stability under large signal disturbances without relying on an accurate system model. Finally, a DRL sub-controller is integrated into the DMFC to intelligently adjust the control signal and enhance the system’s operational adaptability. Experimental results demonstrate that the proposed control method can adaptively ensure the stability of the system under large signal disturbances without requiring an accurate model, while also exhibiting good dynamic and steady-state performance.