Context: The aims of the study are to compare characteristics of subacute thyroiditis (SAT) related to different etiologies, and to identify predictors of recurrence of SAT and incident hypothyroidism. Methods: This nationwide, multicenter, retrospective cohort study included 53 endocrinology centers in Turkey. The study participants were divided into either COVID-19–related SAT (Cov-SAT), SARS-CoV-2 vaccine–related SAT (Vac-SAT), or control SAT (Cont-SAT) groups. Results: Of the 811 patients, 258 (31.8%) were included in the Vac-SAT group, 98 (12.1%) in the Cov-SAT group, and 455 (56.1%) in the Cont-SAT group. No difference was found between the groups with regard to laboratory and imaging findings. SAT etiology was not an independent predictor of recurrence or hypothyroidism. In the entire cohort, steroid therapy requirement and younger age were statistically significant predictors for SAT recurrence. C-reactive protein measured during SAT onset, female sex, absence of antithyroid peroxidase (TPO) positivity, and absence of steroid therapy were statistically significant predictors of incident (early) hypothyroidism, irrespective of SAT etiology. On the other hand, probable predictors of established hypothyroidism differed from that of incident hypothyroidism. Conclusion: Since there is no difference in terms of follow-up parameters and outcomes, COVID-19– and SARS-CoV-2 vaccine–related SAT can be treated and followed up like classic SATs. Recurrence was determined by younger age and steroid therapy requirement. Steroid therapy independently predicts incident hypothyroidism that may sometimes be transient in overall SAT and is also associated with a lower risk of established hypothyroidism.
Purpose: To determine whether early repeat fine needle aspiration biopsy (FNA) has an effect on adequate or atypia of undetermined significance (AUS) cytology rates in thyroid nodules with inadequate or AUS result in the first FNA. Methods: Nodules of patients who underwent repeat biopsy due to insufficient or AUS cytology between 2019–2022 were included. Data of the patients and ultrasonographic, cytological and histopathological results of the nodules were recorded. Additionally, the time between the two biopsies was noted. The first was called “initial” and the second was called “rebiopsy”. Five different paired groups were formed according to the time between two consecutive biopsies; before and after 1 month, 45 days, 2 months, 3 months, and 6 months. The groups were compared in terms of adequate and AUS cytological results. Results: We evaluated 1129 patients with 2187 nodules undergoing FNAB. After excluding nodules with one FNA result and/or missing data, 966 nodules of 628 patients who underwent FNA at least twice were included. Initial cytology was nondiagnostic (ND) in 665 (30.4%) and AUS in 301 (13.8%) nodules. The mean age of the patients was 52.0 ± 11.9 years, and the female sex ratio was 78.8% (n = 495). There were no differences in adequate or AUS rebiopsy results according to the different time interval groups (p > 0.05 for all). AUS result was statistically insignificantly more frequent in nodules with initially AUS nodules when rebiopsy was performed before 1 month in comparison to after 1 month (53.8%, 27.1%; p = 0.054). Accuracy of rebiopsy was also similar in the time intervals groups (p > 0.05 for all). Conclusion: In patients with inadequate or AUS initial biopsy, the rate of adequate or AUS cytology results at rebiopsy did not vary with the timing of repeat biopsy indicating that there may be no need to wait 1 month for a repeat biopsy. In patients with suspicious nodules, biopsy might be repeated before 1 month.
Accurate tumor localization is necessary for the application of minimally invasive surgery, which is preferred in the treatment of primary hyperparathyroidism. Parathormone-washout (PTH-WO) is parathyroid fine-needle aspiration followed by PTH measurement in the needle washout fluid. This study aimed to determine appropriate cutoff values for the PTH-WO method. A total of 402 PTH-WO assays from 339 patients were included in the study. The diagnostic accuracy of the test was assessed by accepting as a positive result a PTH-WO result higher than the serum PTH level [PTH-WO/serum PTH(PTH ratio)>1]. In addition, a cutoff value for the test was established by evaluating the PTH washout results obtained in comparison with postoperative histopathology. Undiluted test results were not included to obtain a clear numerical value in this evaluation. The results of parathyroid scintigraphy and fine needle aspiration biopsy (FNAB) were compared with postoperative histopathology. While 309 (76.86%) of the PTH-WO procedures were considered positive, 93 (23.13%) were considered negative if the PTH ratio was > 1. When these results were compared with the postoperative histopathology, the test's sensitivity was 92.51%, and the specificity was 100.00%. In the analysis of the remaining 292 PTH-WO samples after excluding the undiluted ones, the sensitivity and specificity of the method were 92.3% and 94.1%, respectively, with a PTH ratio > 0.99. With a cutoff value of 99.5 ng/l for PTH-WO value, 93.1% sensitivity and 94.3% specificity were obtained. The sensitivities of parathyroid scintigraphy and FNAB were 53.4% and 15.3%, respectively. The PTH-WO method is safe and cheap, with high sensitivity and specificity in localizing parathyroid tumor. In cases where radiological methods cannot achieve localization with specified cutoff values, it has high diagnostic accuracy.
Medullary thyroid carcinoma (MTC) treatment guidelines recommend surgical extent based primarily on calcitonin levels, yet the oncologic impact of deviatin