Kaustav Kalita

Kaustav Kalita

Auto-generated profile, based on publicly available information

Kaustav Kalita

Indian Inst Technol, Dept Elect Engn, Patna, India

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KKKaustav Kalita
Kaustav Kalita
SAShubham Anand
Shubham Anand
SPSanjoy Parida
Sanjoy Parida
This letter presents a novel non-iterative impedance based two-terminal fault location algorithm with unsynchronized terminals. The novelty of this method lies in the fact that it is noni-terative, does not require signal alignment, are independent of fault classification, suitable for both transposed and untransposed lines with distributed line model. Several results of simulations on standard and practical data of Power Grid Corporation of India Limited (PGCIL). The test results verifies the validity and accuracy of the developed fault location algorithm.

4 August 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KKKaustav Kalita
Kaustav Kalita
SAShubham Anand
Shubham Anand
SPSanjoy Parida
Sanjoy Parida
This paper presents a novel two-terminal fault location algorithm without using line parameters. The algorithm is formulated using unsynchronized voltage and current phasors of the fundamental frequency at both ends. The novelty of the proposed method lies in the fact that it takes into account different angles of synchronism mismatch in pre-fault and fault conditions while considering distributed parameter line model and its solution is in closed form. Simulation results and performance comparison with existing methodology are presented under different fault conditions. The simulations were performed on EMTP-RV platform. The algorithm has also been tested with practical data of Power Grid Corporation of India Limited (PGCIL). The test result shows the validity and accuracy of the developed fault location algorithm.

25 October 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
KKKaustav Kalita
Kaustav Kalita
SAShubham Anand
Shubham Anand
SPS. K. Parida
S. K. Parida
This paper presents an impedance-based non-iterative fault location algorithm for a two-terminal line considering unsynchronized measurements to account for the loss of Global Positioning System (GPS) signal. Based on the availability of pre-fault signals two algorithms are proposed, one using pre-fault data and the other without using pre-fault data. The algorithms are formulated by using fundamental frequency phasor based decoupled modal components of the measured signals at both ends of the line while considering distributed line model. Application of decoupled modal components with distributed model enhances the accuracy of the presented algorithms in both transposed and untransposed configuration of the line. The proposed algorithms have been tested and analyzed with different fault conditions simulated in EMTP-RV platform. Comparative analysis with existing methods is also presented to establish prominent features of the proposed methods. The algorithms have also been tested with practical data of Power Grid Corporation of India Limited (PGCIL) and the test result validates the accuracy of the developed fault location algorithms.

8 June 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KKKaustav Kalita
Kaustav Kalita
SAShubham Anand
Shubham Anand
SPS. K. Parida
S. K. Parida
This letter presents a parameter-free fault location algorithm on a two-terminal double-circuit transposed line with unsynchronized terminals. The presented algorithm is formulated using positive-sequence components of measurands at both terminals. The salient features of the proposed method are that it is non-iterative and does not require pre-fault data. Also, it considers distributed parameter model of a line unlike existing techniques, which adopt lumped model of a line. Simulation results using EMTP-RV platform alongside the results with field data of Power Grid Corporation of India Limited (PGCIL) are presented. The test results established the validity and accuracy of the proposed algorithm.

15 September 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KKKaustav Kalita
Kaustav Kalita
SAShubham Anand
Shubham Anand
SPSanjoy K. Parida
Sanjoy K. Parida
This letter presents a novel parameter-free fault location algorithm for a two-terminal single circuit untransposed line with flat and delta conductor configurations while considering unsynchronized measurements. It improves the existing works by introducing unequal angles of synchronism mismatch in pre-fault and fault conditions. EMTP-RV based simulation results corroborate the validity and accuracy of the developed fault location algorithm. Simulation results are also compared with existing methods to demonstrate improved features of the proposed algorithm. Field test results are also presented to further validate the performance of the proposed algorithm.

17 July 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KKKaustav Kalita
Kaustav Kalita
SAShubham Anand
Shubham Anand
SPS. K. Parida
S. K. Parida
This letter presents a novel fault location algorithm for single circuit untransposed line, which is independent of transmission line parameters and unsynchronized measurement. The novelty of proposed algorithm is that it considers asymmetry in untransposed line while considering unequal angles of synchronism mismatch in pre-fault and fault conditions. Thus, in contrast to existing techniques the proposed algorithm can be applied to conductor configuration other than delta/flat configuration of untransposed line. Simulation results using EMTP-RV platform along with those obtained using field data are presented. The test results verify the accuracy and validity of the proposed method.