Outdoor thermal comfort affects the health of the people and the quality of life in urban areas. This is the reason why in the past few years different mitigation strategies for the microclimate have been studied and examined. These strategies depend on those passive factors characterizing the urban setting that are able to affect the values of local meteorological variables, as the limit surfaces of the urban space (parterre and façades of the buildings). This paper examines the Cloister by Giuliano da Sangallo, which is part of the Faculty of Engineering of Sapienza University of Rome. The case study compares the present configuration of the Cloister with four other configurations characterized by some vegetation and materials with a high albedo by taking into consideration the PMV (Predicted Mean Vote) model. Microclimatic variables are calculated through numerical simulations performed by the ENVI-met software. Such a comparison is performed during a typical summer day. While examining the results it can be noticed how the strategy presenting the best results is the one with some vegetation, whereas the materials with a high albedo improve the microclimate if applied on surfaces characterized by a high sky view factor.
A road tunnel is an enclosed and covered infrastructure for the vehicular traffic. Its lighting system provides 24 h of artificial sources only, with a higher amount of electric power used during the day. Due to safety reasons, when there is natural lighting outside the tunnel, the lighting levels in the stretches right after the entrance and before the exit must be high, in order to guide the driver’s eye towards the middle of the tunnel where the luminance must guarantee safe driving, avoid any over-dimensioning of the lighting systems, and produce energy savings. Such effects can be reached not only through the technological advances in the field of artificial lighting sources with high luminous efficiency, but also through new materials for road paving characterized by a higher reflection coefficient than other ordinary asphalts. This case study examines different technical scenarios, analyzing and comparing possible energy and economic savings. Traditional solutions are thus compared with scenarios suggesting the solutions previously mentioned. Special asphalts are interesting from an economic point of view, whereas the high costs of LED sources nowadays represent an obstacle for their implementation.
The simulation of the energy consumptions in an hourly regime is necessary in order to perform calculations on residential buildings of particular relevance for volume or for architectural features. In such cases, the simplified methodology provided by the regulations may be inadequate, and the use of software like EnergyPlus is needed. To obtain reliable results, usually, significant time is spent on the meticulous insertion of the geometrical inputs of the building, together with the properties of the envelope materials and systems. Less attention is paid to the climate database. The databases available on the EnergyPlus website refer to airports located in rural areas near major cities. If the building to be simulated is located in a metropolitan area, it may be affected by the local heat island, and the database used as input to the software should take this phenomenon into account. To this end, it is useful to use a meteorological model such as the Weather Research and Forecasting (WRF) model to construct an appropriate input climate file. A case study based on a building located in the city center of Rome (Italy) shows that, if the climatic forcing linked to the heat island is not considered, the estimated consumption due to the cooling is underestimated by 35–50%. In particular, the analysis and the seasonal comparison between the energy needs of the building simulated by EnergyPlus, with the climatic inputs related to two airports in the rural area of Rome and with the inputs provided by the WRF model related to the center of Rome, show discrepancies of about (i) WRF vs. Fiumicino (FCO): Δ = −3.48% for heating, Δ = 49.25% for cooling; (ii) WRF vs. Ciampino (CIA): Δ = −7.38% for heating, Δ = +35.52% for cooling.
Outdoor thermal comfort is an essential factor of people’s everyday life and deeply affects the habitability of outdoor spaces. However the indices used for its evaluation were usually developed for indoor environments assuming still air conditions and absence of solar radiation and were only later adapted to outdoor spaces. For this reason, in a previous study the Mediterranean Outdoor Comfort Index (MOCI) was developed, which is an empirical index able to estimate the thermal perception of people living in the Mediterranean area. In this study it was compared numerically (by using the data obtained through a field survey) with other selected thermal indices. This comparison, performed in terms of Spearman’s rho correlation coefficient, association Gamma, percentage of correct predictions and cross-tabulation analysis, led to identify the MOCI as the most suitable index to examine outdoor thermal comfort in the interested area. As a matter of fact it showed a total percentage of correct predictions of 35.5%. Good performances were reported even in thermophysiological indices as the Physiological Equivalent Temperature (PET) and Predicted Mean Vote (PMV). Moreover it was revealed that adaptation and acclimatization phenomena tend to have a certain influence as well.