Shimei Wang

Shimei Wang

Auto-generated profile, based on publicly available information

Shimei Wang

Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
MZMinjie Zhao
Minjie Zhao
FSFuqi Si
Fuqi Si
YWYu Wang
Yu Wang
HZHaijin Zhou
Haijin Zhou
SWShiMei Wang
ShiMei Wang
WLWenqing Liu
Wenqing Liu
Environmental trace gas monitoring instrument (EMI) onboard GaoFen-5 was launched in May 2018 and has successfully operated on-orbit for more than a year. EMI contains four grating spectrometers, covering wavelengths in the range 240-710 nm with a spectral resolution of 0.3-0.5 nm, and enables one-day global coverage. For EMI on-orbit calibration, two onboard solar diffusers (SD), one surface reflectance aluminum diffuser, and one quartz volume diffuser (QVD) are used to measure solar spectra. The solar spectra are used to perform accurate spectral and radiometric calibrations. EMI on-orbit spectral calibration contains wavelength calibration and instrument spectral response function (ISRF), both of which are the key quantities in trace gas retrievals based on differential optical absorption spectroscopy (DOAS) analysis. The wavelength calibration is performed using the Fraunhofer lines in the solar spectrum, and the ISRF parameters are obtained by fitting high-resolution and EMI-measured solar spectra. Based on the known solar irradiation and characteristic of SD, SD radiance can be calculated and is used for EMI on-orbit radiometric calibration. The radiometric calibration also determines the absolute Earth reflectance spectra that are used as inputs for atmospheric retrieval algorithms. For EMI on-orbit radiometric monitoring, aluminum diffuser is used as reference SD to monitor QVD degradation. An internal white light source is used to detect pixel performance and monitor radiometric throughput.

20 July 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
MZMinjie Zhao
Minjie Zhao
FSFuqi Si
Fuqi Si
HZHaijin Zhou
Haijin Zhou
YJYu Jiang
Yu Jiang
CJchunyan ji
chunyan ji
WLWenqing Liu
Wenqing Liu
The environmental trace gas monitoring instrument (EMI) is a space-borne imaging spectrometer onboard GaoFen-5, which was launched in May 2018, covering wavelengths in the range of 240–710 nm to measure NO2, O3, HCHO, and SO2. An advanced EMI-2 instrument with a higher spatial resolution and sufficient signal-to-noise is currently planned for launch on the GaoFen-5(02) satellite in 2021. The EMI-2 instrument bidirectional scattering distribution function (BSDF) is obtained from the absolute irradiance and radiance calibration on-ground. Based on EMI-2 earth and sun optical paths, the key factors of BSDF parameters are introduced. An NIST-calibrated 1000 W FEL quartz tungsten halogen lamp and a 2D turntable are adopted for the absolute irradiance calibration. A large aperture integrating sphere system is used for the absolute radiance calibration. Based on absolute irradiance and radiance calibration functions, the BSDF parameters are obtained, with accuracy of 4.9% for UV1, 4.3% for UV2, 4.1% for VIS1, and 4.2% for VIS2. The on-ground measurement results show that the reflectance spectrum can be calculated from BSDF parameters. On-orbit application of the EMI-2 instrument BSDF are also discussed.

13 February 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
MZMinjie Zhao
Minjie Zhao
HZHaijin Zhou
Haijin Zhou
YJYu Jiang
Yu Jiang
SHShuhua Huang
Shuhua Huang
XZXIN ZHAO
XIN ZHAO
FSFuqi Si
Fuqi Si
This paper presents a space-based limb-imaging spectrometer (LIS) for detecting atmospheric O2 airglow; it scans the atmosphere with a vertical range of 10–100 km and has a vertical resolution of 2 km. The LIS’s detection performance needs to be examined before launch. A forward radiative transfer model (RTM) of airglow is studied to determine the airglow emission intensity. Spectral and radiation calibration is conducted to obtain the response parameters. Based on the airglow emission intensity, calibration results, and airglow spectral lines, the LIS’s simulated spectra are obtained, and then an optimal estimation inversion method for the LIS is studied. The results show that the LIS’s spectral range is 498.1 nm–802.3 nm, with a spectral resolution of 1.38 nm. Simulation results show that the LIS can detect airglow emission spectral lines, which characterize their dependence on temperature. The digital number response value is 20% to 50% of the saturation value. An inversion error analysis shows that, when the signal-to-noise ratio (SNR) of the LIS is 1000 and the prior temperature error is 10%, the inversion errors are 6.2 and 3 K at 63 and 77 km, respectively. This study shows that the LIS can achieve good SNR detection for airglow.