A novel predictive rotor current control scheme for a doubly fed induction generator (DFIG) is implemented to perform the DFIG grid synchronization with a fast dynamic response. With this control strategy applied to an experimental setup, the rotor currents swiftly follow the necessary reference for grid synchronization in the range ±30% of the generator rated shaft speed. The DFIG and converter discrete models are used to predict the behavior of the rotor currents. By minimizing the error between the references and the predictive rotor currents for each of the valid states of the converter, the best-suited switching state is selected and applied at the next sampling time. To validate the feasibility of implementing this approach, simulations and experiments were carried out for various shaft speed profiles.
A simple and intuitive Doubly Fed Induction Generator (DFIG) predictive rotor current control scheme is presented. Predictive control of an Indirect Matrix Converter (IMC) is combined with predictive rotor current control of a DFIG to achieve a very good dynamic response as the rotor currents smoothly follow the applied reference in a ±30% range of the generator nominal rpm. Simulation results are presented for constant torque and rotational speed, as well as for variable rotational speed corresponding to a 10 kW generator dynamic response. Derivation and conjunction of each model equations are also presented along with a delay error compensation strategy to counter the practical implementation issue implicit in discrete time control computation.
17 November 2020 in IEEE Transactions on Energy Conversion
This paper presents a new control strategy using model-based predictive current control (MB-PCC) for a doubly fed induction machine (DFIM) driven by an indirect matrix converter (IMC). This strategy proposes the control of rotor currents, whose references are calculated from active and reactive stator power set points and the dynamic model of the DFIM. The control strategy works well in the four P-Q operating regions of the DFIM. The grid synchronization process is carried out by setting the P-Q power set points to zero. The results presented include the DFIM synchronization procedure as well as the active and reactive power control at variable shaft speed to validate the feasibility of the proposed strategy.
Wind energy use has shown a remarkable increase in last years. In order to achieve the highest efficiency with the best characteristics in wind turbines, it is necessary to analyze relevant factors in wind energy conversion. In this review a state of the art is presented focused on modeling, constitutive elements, structure and control of wind generation systems and the increasing use of wind energy worldwide is evidenced.
In this paper two control techniques: Finite States - Model Based Predictive Control (FS - MBPC) and Fuzzy Logic Control (FLC) are developed to obtain arbitrary output currents, needed in a variable speed Wind Energy Conversion System (WECS). In this study, the simulation performance between FS-MBPC and FLC of the rotor current in a Doubly Fed Induction Generator (DFIG) with an Indirect Matrix Converter is evaluated. The simulations were carried out with constant shaft speed, and constant ramp speed with arbitrary rotor current references. Both FS-MBPC and FLC showed very high performance, following smoothly and rapidly the current reference with a very low error. The FS-MBPC dynamic response is slightly better than of the FLC. However, fewer mathematical calculations, and less measured data, and fewer computational requirements suggest that FLC can be easier to implement in FPGAs instead of composite microprocessor-based control platforms.
This paper presents a soft-computing technique to control the rotor current of a Doubly Fed Induction Generator (DFIG) using an Indirect Matrix Converter (IMC). The technique developed uses fuzzy logic to successfully control the rotor current, even with abnormal grid conditions, by governing the IMC rectifier and inverter sides. Although this control problem has been already analyzed and solved with conventional vector control and with Finite States Model Based Predictive Control (FS-MBPC), the fuzzy logic based controllers have a very acceptable response. The advantages of the developed technique are simpler code without the need of a specific mathematical model and robustness under grid abnormalities. These benefits decrease system costs, increase overall reliability and allow the control scheme to be implemented easily and entirely in FPGAs instead of DSPs-FPGA control systems.