6 March 2019 in IEEE Transactions on Power Systems
Transmission faults caused by recent wildfires in California induced the disconnection of utility-scale converters in photovoltaic (PV) power plants. Postmortem investigations reported that tripping commands were caused by phase-locked loops (PLLs) and dc-side dynamics, which are typically unmodeled in transient stability studies. Since existing simulation packages rely on simplified models that neglect these dynamics, they have a limited capability to predict converter behavior during faults. To address this shortcoming, we set forth a positive-sequence model for PV power plants that is derived from physics and controls first principles. As seen on utility-scale three-phase converters, the model includes PLLs, dc-side dynamics, and closed-loop controllers. Instances of the developed model are integrated into illustrative power systems containing also conventional generators. Numerical simulations of the obtained multi-machine multi-converter power systems are assessed via a suitable set of stability and performance metrics.
7 April 2022 in IEEE Transactions on Power Systems
Photovoltaic (PV) power plants with grid-forming technology must withstand severe disturbances and remain operational. To address this challenge, this paper sets forth a grid-forming strategy for PV solar power plants so that they can ride through power system faults. This capability is accomplished by leveraging two-axis proportional-integral regulators with anti-windup functionality. This paper also demonstrates that fluctuations of solar irradiance can cause significant dc-link voltage variations and loss of synchronism of grid-forming PV plants. Hence, we develop an active dc-link protection method which depends on estimation of solar irradiance. The contributions of this paper are demonstrated via positive-sequence simulations of modified versions of the WSCC 9- and IEEE 39-bus grids.
10 May 2022 in IEEE Transactions on Energy Conversion
The blackstart capability of wind turbines is critical for the recovery of wind-dominant power systems from blackouts. If wind power plants are not able to restore a power system, the incorporation of wind resources into electric grids could be limited by blackstart capability. This paper tackles this problem by setting forth a grid-forming controller for Type 4 wind turbines which employ fully rated power converters. To this end, we engineer two-axis anti-windup proportional-integral regulators that serve to ride through restoration disturbances. We also design an active protection system to prevent wind turbines from stalling during recovery from blackouts. We demonstrate in a high-fidelity simulation environment that Type 4 wind turbines with the developed controllers and protection subsystem can: (i) re-energize a notional wind-dominant grid; (ii) ride through asymmetrical faults; and (iii) survive low wind speed events.
12 October 2022 in IEEE Transactions on Smart Grid
Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. The controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.
3 January 2023 in IEEE Transactions on Transportation Electrification
An emerging problem in power engineering pertains to ascertaining the impacts of fast-charging processes of all-electric vehicles (EVs) on electric grids. This problem exacerbates in subzero climates because it is necessary to pre-heat battery cells within EVs before fast charging to mitigate lithium plating. To study such processes, we set forth detailed and reduced-order simulation models as to determine grid power requirements for ac-heating and fast-charging of EVs. The detailed representation considers ac and dc control loops, a four-quadrant power converter, and an estimator of the state of charge of the EV battery pack. The reduced-order model has close agreement with detailed real-time simulation and laboratory experimentation.
4 June 2024 in IEEE Electrification Magazine
The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. This has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.