Brian Johnson

Brian Johnson

Auto-generated profile, based on publicly available information

Brian Johnson

Chandra Family Department of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
NBNathan Baeckeland
Nathan Baeckeland
DCDebjyoti Chatterjee
Debjyoti Chatterjee
MLMinghui Lu
Minghui Lu
BJBrian Johnson
Brian Johnson
Gab-Su SeoGab-Su Seo
Gab-Su Seo
Grid-forming (GFM) inverters are increasingly recognized as a solution to facilitate massive grid integration of inverter-based resources and enable 100% power-electronics-based power systems. However, the overcurrent characteristics of GFM inverters exhibit major differences from those of conventional synchronous machines. Accordingly, an in-depth characterization of GFM current-limiting strategies is needed to ascertain their performance during off-nominal conditions. Although GFM current-limiting controls are primarily necessary to protect the inverter power stage, they determine the inverter behavior during and after an off-nominal system disturbance. As a result, they can profoundly impact device-level stability, transient system stability, power system protection, and fault recovery. This article offers a comprehensive review of state-of-the-art current-limiting techniques for GFM inverters and outlines open challenges where innovative solutions are needed. One key contribution of this article is the use of graphical methods that allow for intuitive understanding and visually aided comparisons of current-limiting methods. With this approach, we evaluate various performance criteria for different limiting methods, such as fault current contribution, voltage support, stability, and post-fault recovery. We also discuss the latest standards and trends as they require inverter dynamics under off-nominal conditions and outline pathways for future developments.

25 March 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MLMinghui Lu
Minghui Lu
SDSairaj Dhople
Sairaj Dhople
BJBrian Johnson
Brian Johnson
Virtual oscillator control (VOC) is a time-domain strategy that leverages the dynamics of nonlinear oscillator circuits for synchronizing and regulating grid-forming inverters. In this article, we examine a class of second-order circuits composed of a harmonic oscillator and nonlinear state-dependent damping that has found extensive interest in the context of VOC. We center our analysis on the Van der Pol, Dead-zone, and Andronov-Hopf oscillators; these are characterized by several distinguishing attributes but they all share the common structure noted above. Analytical methods based on averaging and perturbation theory are outlined to derive several performance metrics related to harmonic and dynamic properties of these oscillators under a unified framework. Our results reveal that the Andronov-Hopf oscillator is well suited for grid-forming inverter applications since it can yield harmonics-free waveforms without compromising dynamic performance. Analytical results are validated with numerical simulations and experiments, and a multiinverter hardware setup is used to illustrate a practical use case.

6 March 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
HPHugo Nestor Villegas Pico
Hugo Nestor Villegas Pico
BJBrian B. Johnson
Brian B. Johnson
Transmission faults caused by recent wildfires in California induced the disconnection of utility-scale converters in photovoltaic (PV) power plants. Postmortem investigations reported that tripping commands were caused by phase-locked loops (PLLs) and dc-side dynamics, which are typically unmodeled in transient stability studies. Since existing simulation packages rely on simplified models that neglect these dynamics, they have a limited capability to predict converter behavior during faults. To address this shortcoming, we set forth a positive-sequence model for PV power plants that is derived from physics and controls first principles. As seen on utility-scale three-phase converters, the model includes PLLs, dc-side dynamics, and closed-loop controllers. Instances of the developed model are integrated into illustrative power systems containing also conventional generators. Numerical simulations of the obtained multi-machine multi-converter power systems are assessed via a suitable set of stability and performance metrics.

16 November 2018 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
VPVictor Purba
Victor Purba
BJBrian B. Johnson
Brian B. Johnson
MRMiguel Rodriguez
Miguel Rodriguez
SJSaber Jafarpour
Saber Jafarpour
FBFrancesco Bullo
Francesco Bullo
SDSairaj V. Dhople
Sairaj V. Dhople
This paper outlines a reduced-order aggregate dynamical model for parallel-connected single-phase grid-connected inverters. For each inverter, we place no restrictions on the converter topology and merely assume that the ac-side switch-averaged voltage can be controlled via pulse width modulation. The ac output of each inverter interfaces through an LCL filter to the grid. The closed-loop system contains a phase locked loop for grid synchronization, and real- and reactive-power control are realized with inner and outer PI current- and power-control loops. We derive a necessary and sufficient set of parametric relationships to ensure that a reduced-order aggregated state-space model for an arbitrary number of such paralleled inverters has the same model order and structure as any single inverter. We also present reduced-order models for the settings where the real- and reactive-power setpoints are different and where the inverters have different power ratings. We anticipate the proposed model being useful in analyzing the dynamics of large collections of parallel-connected inverters with minimal computational complexity. The aggregate model is validated against measurements obtained from a multi-inverter experimental setup consisting of three 750 VA paralleled grid-connected inverters, hence establishing robustness of the analytical result to parametric variations seen in practice.

4 September 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MSMohit Sinha
Mohit Sinha
JPJason Poon
Jason Poon
BJBrian B. Johnson
Brian B. Johnson
MRMiguel Rodriguez
Miguel Rodriguez
SDSairaj V. Dhople
Sairaj V. Dhople
We present a decentralized control strategy that yields switch interleaving for parallel-connected dc-dc buck converters. Compared to state-of-the-art methods that are distributed at best, the proposed architecture requires no communication and hence presents a variety of advantages with regard to reliability, modularity, and cost. The method is based on the digital implementation of the dynamics of a Lienard-type oscillator circuit as the controller for the converters. Each controller only requires the locally measured output current to synthesize the pulse width modulation (PWM) carrier waveform. The intrinsic electrical coupling between converters drives the nonlinear oscillator-based controllers to converge to an interleaved state with uniform phase-spacing across PWM carriers, independent of the number of converters, the load, and initial conditions. We provide analytical guarantees for existence and stability of the interleaved state as well as extensive hardware results for a system of five 120 W, 48 V to 12 V dc-dc buck converters that demonstrate convergence to the interleaved state in the face of a variety of large-signal disturbances.

25 May 2021 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
OAOlaoluwapo Ajala
Olaoluwapo Ajala
MLMinghui Lu
Minghui Lu
BJBrian B Johnson
Brian B Johnson
SDSairaj V. Dhople
Sairaj V. Dhople
ADAlejandro Dominguez-Garcia
Alejandro Dominguez-Garcia
This paper outlines reduced-order models for grid-forming virtual-oscillator-controlled inverters with nested current- and voltage-control loops, and current-limiting action for over-current protection. While a variety of model-reduction methods have been proposed to tame complexity in inverter models, previous efforts have not included the impact of current-reference limiting. In addition to acknowledging the current-limiting action, the reduced-order models we outline are tailored to networks with resistive and inductive interconnecting lines. Our analytical approach is centered on a smooth function approximation for the current-reference limiter, participation factor analysis to identify slow- and fast-varying states, and singular perturbation to systematically eliminate the fast states. Computational benefits and accuracy of the reduced-order models are benchmarked via numerical simulations that compare them to higher-order averaged and switched models.