Yadong Feng

Yadong Feng

Auto-generated profile, based on publicly available information

Yadong Feng

NR Electric, Nanjing, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2016 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
BLBin Li
Bin Li
JHJiawei He
Jiawei He
JTJie Tian
Jie Tian
YFYadong Feng
Yadong Feng
YDYunlong Dong
Yunlong Dong
DC fault protection is the key technique for the development of the DC distribution and transmission system. This paper analyzes the transient characteristics of DC faults in a modular multilevel converter (MMC) based DC system combining with the numerical method. Meanwhile, lots of simulation tests based on MATLAB/Simulink are carried out to verify the correctness of the theoretical analysis. Finally, the technological difficulties of and requirements for the protection and isolation are discussed to provide the theoretical foundation for the design of dc fault protection strategy.