Yvette Seppenwoolde

Yvette Seppenwoolde

Auto-generated profile, based on publicly available information

Yvette Seppenwoolde

Department of Radiotherapy, The Netherlands Cancer Institute/Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2002 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
YSYvette Seppenwoolde
Yvette Seppenwoolde
HSHiroki Shirato
Hiroki Shirato
KKKei Kitamura
Kei Kitamura
SSShinichi Shimizu
Shinichi Shimizu
MHMarcel van Herk
Marcel van Herk
KMKazuo Miyasaka
Kazuo Miyasaka

1 March 2003 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
YSYvette Seppenwoolde
Yvette Seppenwoolde
JLJoos V. Lebesque
Joos V. Lebesque
KJKatrien de Jaeger
Katrien de Jaeger
JBJosé S.A. Belderbos
José S.A. Belderbos
LBLiesbeth J. Boersma
Liesbeth J. Boersma
RHRandall K. Ten Haken
Randall K. Ten Haken

1 January 2004 in Seminars in Radiation Oncology
Verified
Journal Article
Closed access
HSHiroki Shirato
Hiroki Shirato
YSYvette Seppenwoolde
Yvette Seppenwoolde
KKKei Kitamura
Kei Kitamura
RORikiya Onimura
Rikiya Onimura
SSShinichi Shimizu
Shinichi Shimizu

13 June 2007 in Medical Physics
Verified
Journal Article
Closed access
YSYvette Seppenwoolde
Yvette Seppenwoolde
RBRoss I. Berbeco
Ross I. Berbeco
SNSeiko Nishioka
Seiko Nishioka
HSHiroki Shirato
Hiroki Shirato
BHBen Heijmen
Ben Heijmen

1 January 2003 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
SESara C Erridge
Sara C Erridge
YSYvette Seppenwoolde
Yvette Seppenwoolde
SMSara H Muller
Sara H Muller
MHMarcel van Herk
Marcel van Herk
KJKatrien De Jaeger
Katrien De Jaeger
JLJoos V Lebesque
Joos V Lebesque

17 February 2003 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
TNToni Neicu
Toni Neicu
HSHiroki Shirato
Hiroki Shirato
YSYvette Seppenwoolde
Yvette Seppenwoolde
SJSteve B Jiang
Steve B Jiang
Synchronized moving aperture radiation therapy (SMART) is a new technique for treating mobile tumours under development at Massachusetts General Hospital (MGH). The basic idea of SMART is to synchronize the moving radiation beam aperture formed by a dynamic multileaf collimator (DMLC) with the tumour motion induced by respiration. SMART is based on the concept of the average tumour trajectory (ATT) exhibited by a tumour during respiration. During the treatment simulation stage, tumour motion is measured and the ATT is derived. Then, the original IMRT MLC leaf sequence is modified using the ATT to compensate for tumour motion. During treatment, the tumour motion is monitored. The treatment starts when leaf motion and tumour motion are synchronized at a specific breathing phase. The treatment will halt when the tumour drifts away from the ATT and will resume when the synchronization between tumour motion and radiation beam is re-established. In this paper, we present a method to derive the ATT from measured tumour trajectory data. We also investigate the validity of the ATT concept for lung tumours during normal breathing. The lung tumour trajectory data were acquired during actual radiotherapy sessions using a real-time tumour-tracking system. SMART treatment is simulated by assuming that the radiation beam follows the derived ATT and the tumour follows the measured trajectory. In simulation, the treatment starts at exhale phase. The duty cycle of SMART delivery was calculated for various treatment times and gating thresholds, as well as for various exhale phases where the treatment begins. The simulation results show that in the case of free breathing, for 4 out of 11 lung datasets with tumour motion greater than 1 cm from peak to peak, the error in tumour tracking can be controlled to within a couple of millimetres while maintaining a reasonable delivery efficiency. That is to say, without any breath coaching/control, the ATT is a valid concept for some lung tumours. However, to make SMART an efficient technique in general, it is found that breath coaching techniques are required.