2 April 2024 in Agricultural Water Management
14 July 2021 in IEEE Transactions on Industrial Electronics
Low-voltage multiterminal dc system is one of the important forms in distribution network. Its stability issue has drawn worldwide attention for the characteristics of low inertia and weak damping. This article aims to analyze the interactive behavior between the voltage source converter (VSC) and the oscillation mode of the dc network. First, this article proposed a modeling method for dc voltage control loop considering the time-lag effect of inductor energy storage behavior on the ac side of the VSC. Based on this model, the interactive behavior between VSC and dc network, including the influence of droop coefficients and load power under dc voltage–ac power ( V dc – P ac ) droop control mode and under dc voltage–dc power ( V dc – P dc ) droop control mode, is studied. Then, the overall state-space model of the system is established. Furthermore, the stability of a low-voltage three-terminal dc system under different control modes and parameters is compared and analyzed in detail. Finally, the corresponding simulation and experimental verification validate the theoretical analysis. The research results show that under the same capacity and control parameters, V dc – P ac mode can better improve the capability of power regulation and system stability. This research can provide an effective method for system control modes design.
23 August 2023 in IEEE Transactions on Smart Grid
The low damping of a multi-terminal low-voltage direct current (MT-LVDC) system with the influence of negative impedance characteristic in DC network, can reduce the system stability. This study aims to find an additional control method to extend the system stable operating region on the premise of not changing the local control system of each converter and not affecting the accurate tracking of each converter’s power command under their normal dispatching, thereby significantly extending the stable operating region of a MT-LVDC system by small damping powers, and ensuring the stable DC voltage when operating point changes. First, an additional control method based on feedback linearization is proposed. Then an analytical expression of damping powers required to realize additional control is built, and a method to obtain the overall stable operating region is established. Furthermore, a multi-objective optimization model for additional control is proposed, and the optimized additional controller is obtained using Pareto front solution. The proposed method is experimentally verified to be able to provide an effective method to improve the system stability with simple control structure and low complexity, which can be conveniently implemented in the MT-LVDC system.
27 October 2025 in IEEE Transactions on Industry Applications
How to achieve urban power restoration with the help of microgrid (MG) in the face of natural disasters has become a research hotspot. This paper aims to research a flexible interconnection method to enhance power supply capacity. First, a flexible DC interconnection method covering a large spatial area is proposed. Then, based on a modular modeling method for high-order systems considering interaction characteristics of Voltage Source Converter (VSC) ports, an interconnection selection method is built to compare the power supply performance of system under star structure and hand-in-hand structure. Furthermore, a dynamic adjustment strategy based on control mode is formed. Finally, the corresponding simulation and experimental verification shows that the proposed method is able to obtain optimal structure and master station to get the maximum power supply capability, while still ensuring high reliability in the face of secondary disasters.
1 January 2005 in Journal of Software
Dynamic power management (DPM) is a design methodology aiming at reducing power consumption of electronic systems. The effectiveness of a power management scheme depends critically on the power management policy and control algorithm. In this work, it is found that the exponential distribution supposition taken by traditional queuing theory is not suitable to DPM, and the timeout policy is enough for DMP. The reason that the simple timeout policy could reduce much energy consumption of computer devices is the self-similarity nature of computer service requests. This paper proposes an adaptive control algorithm for DPM of embedded operating system when the idle time length fits Pareto distribution. It adopts the Trimmed Mean Estimator to realize the robust efficient estimation of the tail index parameter of Pareto distribution for small sample size, and is implemented using window-size-based adaptive control method. Simulation results show that the algorithm presented in this paper is robust. The competitive ratio is reduced to 1.24 and even 1.47 when the delay is smaller than 0.10. Overhead of the adaptive control algorithm is low.
24 March 2022 in Energy Reports