Potassium (K) is among the macronutrients required for crop production and it is absorbed through plant roots from the soil solution. Replenishment of soil K is usually done by fertilizer application; therefore, it is crucial to know the amount of this nutrient that's available in the soil. There's very little literature reporting a turbidimetric method for K determination, and even less in soil samples. The objective of this work is to evaluate a portable low-cost system that allows turbidimetric determination to assess the amount of available K in soil. The turbidimetric method consists of K precipitation with sodium tetraphenylborate (NaTPB). The time and Mehlich-1, Mehlich-1 diluted 1 : 1 and water solutions for the extraction procedure were evaluated. The effect of pH, along with NaTPB volume and sensor signal stability, was also evaluated. With the optimized conditions, calibration of the sensor showed a good linearity (r2 = 0.9982), and the limits of detection and quantification were 0.1 and 0.3 mg L−1 of K, respectively. No significant difference (t test with 95% confidence level) is observed between the results obtained with the sensor and the MP-AES and ICP OES determinations using Mehlich-1 solution for K extraction. The results presented here demonstrate that it is possible to use simple equipment to measure available K in soil on the field by using low amounts of reagents, which could make this analysis more accessible.
26 October 2022 in Brazilian Journal of Analytical Chemistry
Rice is a food consumed worldwide and there is a grown concern about its nutritional value, as well as the concentration of contaminant elements. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was employed in the present work for determination and imaging of Mg, Mn, Cu, Co, Fe, Zn, As, Sr, Sb, Ba and Pb in grains of white, parboiled, and whole (brown) rice. The elements quantification was achieved by using external calibration whereas filter paper discs served as support for the reference solutions and matrix matching. Accuracy was ensured by analysing two certified reference materials (CRMs) pressed into pellets. Investigations were carried out to evaluate the distribution of the elements on the surface and external layers of the grains. For that purpose, the surface of rice grains fixed on a glass support was ablated line-by-line and the ablation repeated three times. The images generated from laser ablation revealed that the investigated elements were not homogeneously distributed in the analysed parts of the grains. Except for Pb, the investigated elements were detected in three layers of the rice grains, but it was observed that the elements concentrations decreased from the surface to more internal layers. Lead was detected only in the first layer of white and whole rice and in the first and second layers of parboiled rice.
This work focuses on the development of a simple and sensitive voltammetric method for the antidepressant mirtazapine (MIR) determination in aqueous environmental samples by using carbon screen printed electrodes (SPE). Electrochemical characteristics of MIR were evaluated by cyclic voltammetry (CV). The results indicate an irreversible oxidation process controlled by diffusion, involving a ratio of 1:1 of electrons and protons exchange. Differential pulse voltammetry (DPV) and square wave voltammetry (SWV) were used for MIR quantification. Phosphate, Tris-HCl and BR buffers were evaluated in order to establish the best supporting electrolyte, where the good analytical performance was achieved by DPV using BR 0.1 mol L-1 at pH 7.0. The method showed good linearity in the concentration range of 0.94 to 28.76 μmol L-1 MIR, with good repeatability (RSD less than 10%), sensitivity, accuracy and robustness. Limits of detection and quantification were 0.22 and 0.67 μmol L-1, respectively. The method was applied for MIR determination in drinking water, surface water and domestic effluent. Samples were only filtered before analysis. MIR was not detected. Analyte recovery and comparison of the results with UV spectrophotometry were used to check interferences and accuracy of the method. Analyte recovery is in the range of 99% to 106%, and good agreement of the results from UV was achieved. The work shows the viability of using carbon SPEs as a rapid analytical method for emerging contaminant determination with minimal sample treatment, turning the method useful for in field application.
1 January 2026 in Journal of the Brazilian Chemical Society
Madeira River (Rondônia State, Brazil) is known to be contaminated with mercury (Hg), which can be biomagnified and bioaccumulated through the food chain. The situation raises concern given there are riverside inhabitants that consume fish. Therefore, 18 fish species with a broad spectrum of eating habits were investigated. Mercury concentrations in fish muscle were evaluated according to the limits established by the Brazilian National Health Surveillance Agency (ANVISA) and the European Union (EU). ANVISA sets maximum limits of 1.0 µg g-1 for predator species and 0.5 µg g-1 for non-predator species (Brazil), whereas EU establishes a maximum limit of 0.5 µg g-1 (EU). Thirteen species have Hg levels above the maximum recommended (ANVISA limits). The Hg concentration ranged from 0.15 to 20.7 and 0.012 to 1.14 µg g-1 for predatory and non‑predatory fish, respectively. A flow batch chemical vapor generation-inductively coupled plasma mass spectrometric (CV-ICP-MS) method was used, with limit of detection (LOD) of 0.012 µg g-1, value below the maximum limit for mercury in fish established by ANVISA and the European Union. Accuracy was evaluated by analyzing certified refence material (CRM), with precision better than 5% (relative standard deviation, n = 5). The results demonstrate the current status of Hg in fish and highlight the seriousness of environmental contamination, as mercury concentrations in several species exceed expected levels. In addition, Hg levels in fish muscle are comparable to or higher than those reported in studies conducted in the same region since 2000.