Cristiane Pappis

Cristiane Pappis

Auto-generated profile, based on publicly available information

Cristiane Pappis

Universidade de Santa Cruz do Sul

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Brazilian Journal of Analytical Chemistry
Verified
Journal Article
Closed access
Adilson Ben CostaAdilson Ben Costa
Adilson Ben Costa
CPCristiane Pappis
Cristiane Pappis
MLMarcia Librelotto
Marcia Librelotto
LBLuiza Baumann
Luiza Baumann
APAlessandra Parckert
Alessandra Parckert
ELEduardo Alcayaga Lobo
Eduardo Alcayaga Lobo

8 April 2021 in Revista Jovens Pesquisadores
Verified
Journal Article
Open access
PDF file
LBLuiza Baumann
Luiza Baumann
EPEduarda Ferreira Pessel
Eduarda Ferreira Pessel
CPCristiane Pappis
Cristiane Pappis
LFLetícia Ana Fischborn
Letícia Ana Fischborn
MLMarcia Librelotto
Marcia Librelotto
Adilson Ben CostaAdilson Ben Costa
Adilson Ben Costa
Com o aumento da demanda por métodos que seguem os princípios da química analítica verde e devido a necessidade de maior produtividade das áreas cultivadas, novas técnicas de análise em tecido vegetal têm sido estudadas. Ultimamente, o uso da espectroscopia molecular vem se destacando, principalmente por apresentar resposta rápida em diversos tipos de análises, além de apresentar gastos significativamente menores em relação a outros métodos convencionais de laboratório. Assim, o presente estudo tem o objetivo de avaliar o uso da espectroscopia no infravermelho próximo aliado a métodos quimiométricos, para análise de nitrogênio em tecido vegetal. Para tanto, espectros de infravermelho na faixa de 960-2.400 nm de diversas espécies, foram obtidos a partir de uma mesa auto-amostradora. O equipamento produz um espectro de varredura com área de superfície de 4 cm2, na região entre 450-2450 nm, com capacidade de 40 amostras e frequência analítica da ordem 6 amostras por minuto. Os modelos de calibração foram realizados utilizando o software SOLO+MIA (Eigenvector Research, Inc), 8.6.1, com diferentes técnicas de pré-tratamentos dos espectros. Os resultados de concentração de nitrogênio não diferiram estatisticamente (p = 0,987) daqueles obtidos pelo método oficial. O modelo desenvolvido apresentou os seguintes erros, RMSEC 1,25 g kg-1; RMSECV 2,22 g kg-1 e R2 cal 0,986. Deste modo, observa-se que os resultados foram satisfatórios, legitimando que é possível o uso de espectroscopia NIR para estes tipos de análise.

27 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
AVAna Barbosa Viana
Ana Barbosa Viana
CPCristian Kelling Pereira
Cristian Kelling Pereira
TRTaynara Bonfim Riquiere
Taynara Bonfim Riquiere
IPIonara Pizzutti
Ionara Pizzutti
CPCristiane Pappis
Cristiane Pappis
VDValderi Luiz Dressler
Valderi Luiz Dressler
This work focuses on the development of a simple and sensitive voltammetric method for the antidepressant mirtazapine (MIR) determination in aqueous environmental samples by using carbon screen printed electrodes (SPE). Electrochemical characteristics of MIR were evaluated by cyclic voltammetry (CV). The results indicate an irreversible oxidation process controlled by diffusion, involving a ratio of 1:1 of electrons and protons exchange. Differential pulse voltammetry (DPV) and square wave voltammetry (SWV) were used for MIR quantification. Phosphate, Tris-HCl and BR buffers were evaluated in order to establish the best supporting electrolyte, where the good analytical performance was achieved by DPV using BR 0.1 mol L-1 at pH 7.0. The method showed good linearity in the concentration range of 0.94 to 28.76 μmol L-1 MIR, with good repeatability (RSD less than 10%), sensitivity, accuracy and robustness. Limits of detection and quantification were 0.22 and 0.67 μmol L-1, respectively. The method was applied for MIR determination in drinking water, surface water and domestic effluent. Samples were only filtered before analysis. MIR was not detected. Analyte recovery and comparison of the results with UV spectrophotometry were used to check interferences and accuracy of the method. Analyte recovery is in the range of 99% to 106%, and good agreement of the results from UV was achieved. The work shows the viability of using carbon SPEs as a rapid analytical method for emerging contaminant determination with minimal sample treatment, turning the method useful for in field application.