Precise dispensing of microdroplets is an important process for droplet-based microfluidics. The droplet formation by shear force between two immiscible fluids depends on their flow rates, the viscosities, and the interfacial tension. In this letter, the authors report the use of integrated microheater and temperature sensor for controlling the droplet formation process. The technique exploits the dependency on temperature of viscosities and interfacial tension. Using a relatively low heating temperature ranging from 25to70°C, the droplet diameter can be adjusted to over two times of its original value. The relatively low temperature range makes sure that this concept is applicable for droplets containing biological samples.
The authors used thermally induced surface tension gradients to manipulate aqueous droplets in microchannels. Control of the droplet breakup process was demonstrated. Droplet sorting can be achieved with temperatures above a critical value. Numerical simulation using a two-dimensional model agrees qualitatively well with the experimental results. The used control temperature of less than shows that this active control concept is suitable for biochemical applications. Thermal control promises to be a simple and effective manipulation method for droplet-based lab on a chip.
2 March 2009 in Journal of Physics D: Applied Physics