Wim Sijbers

Wim Sijbers

Auto-generated profile, based on publicly available information

Wim Sijbers

IMEC, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2019 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Shuang SongShuang Song
Shuang Song
PVPeter Vis
Peter Vis
CLChris van Liempd
Chris van Liempd
CHChris Van Hoof
Chris Van Hoof
NHNick Van Helleputte
Nick Van Helleputte
ABArjan Breeschoten
Arjan Breeschoten
An all-in-one battery powered low-power SoC for measuring multiple vital signs with wearables is proposed. All functionality needed in a typical wearable use case scenario, including dedicated readouts, power management circuitry, digital signal processing and wireless communication (BLE) is integrated in a single die. This high level of integration allows an unprecedented level of miniaturization leading to smaller component count which reduces cost and improves comfort and signal integrity. The SoC includes an ECG, Bio-Impedance and a fully differential PPG readout and can interface with external sensors (like an IMU). In a typical application scenario where all sensor readouts are enabled and key features (like heart rate) are calculated on the chip and streamed over the radio, the SoC consumes only 769μW from the regulated 1.2V supply.

19 September 2019 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Shiwei WangShiwei Wang
Shiwei Wang
CLCarolina Mora Lopez
Carolina Mora Lopez
SGSeyed Kasra Garakoui
Seyed Kasra Garakoui
HCHosung Chun
Hosung Chun
DSDídac Gómez Salinas
Dídac Gómez Salinas
NHNick Van Helleputte
Nick Van Helleputte
Large-scale $in\ vivo$ electrophysiology requires tools that enable simultaneous recording of multiple brain regions at single-neuron level. This calls for the design of more compact neural probes that offer even larger arrays of addressable sites and high channel counts. With this aim, we present in this paper a quad-shank approach to integrate as many as 5,120 sites on a single probe. Compact fully-differential recording channels were designed using a single-gain-stage neural amplifier with a 14-bit ADC, achieving a mean input-referred noise of 7.44 μ $\text{V}_{\text{rms}}$ in the action-potential band and 7.65 μ $\text{V}_{\text{rms}}$ in the local-field-potential band, a mean total harmonic distortion of 0.17% at 1 kHz and a mean input-referred offset of 169 μV. The probe base incorporates 384 channels with on-chip power management, reference-voltage generation and digital control, thus achieving the highest level of integration in a neural probe and excellent channel-to-channel uniformity. Therefore, no calibration or external circuitry are required to achieve the above-mentioned performance. With a total area of $2.2 \times 8.67\text{ mm}^2$ and a power consumption of 36.5 mW, the presented probe enables full-system miniaturization for acute or chronic use in small rodents.

15 January 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
QLQiuyang Lin
Qiuyang Lin
Shuang SongShuang Song
Shuang Song
ICIvan Castro
Ivan Castro
HJHui Jiang
Hui Jiang
MKMario Konijnenburg
Mario Konijnenburg
NHNick Van Helleputte
Nick Van Helleputte
Remote home monitoring via wearables is rapidly gaining popularity, thanks to ever more complex vital signs recording and data analytics that are embedded into single devices. True system-on-chips (SoCs) push the envelope of power and form factor, while wearables are becoming more common-place, novel health sensing paradigms appear. Non-contact sensing technologies enable vital signs sensing without requiring any physical contact with the human body. This paper reviews existing multiple-modality bio-signal recording and processing SoCs, circuit techniques for individual bio-signal readout channels including electrocardiography (ECG), Electroencephalography (EEG), Bio-impedance (BioZ), photoplethysmography (PPG), and non-contact sensing with high user comfort. The stateof- the-art wearable sensor interfaces and systems together with future development trends are provided.

23 September 2019 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
HHHyunsoo Ha
Hyunsoo Ha
WSWim Sijbers
Wim Sijbers
RWRoland Van Wegberg
Roland Van Wegberg
JXJiawei Xu
Jiawei Xu
MKMario Konijnenburg
Mario Konijnenburg
NHNick Van Helleputte
Nick Van Helleputte
The measurement of the tissue or bio-impedance (BIOZ) is a safe and power-efficient sensing modality that can be adopted for the acquisition of vital signals, such as respiration and heartbeat. A BIOZ readout IC with a wide-input impedance range is proposed. The IC supports vital signal acquisition through a two-electrode setup which requires a larger dynamic range than the conventional four-electrode setup. A digital-assisted baseline impedance cancellation method is implemented to measure small tissue impedance variations originating from respiration and heartbeat in the presence of larger baseline impedances. The proposed technique also mitigates the input-dependent noise behavior of the readout front-end by minimizing the effective input signal to the instrumentation amplifier (IA). The baseline cancellation loop further improves the noise performance by cancelling the reference current noise from the current generator (CG). Hence, one single solution--baseline cancellation--resolves two issues facilitating two-electrode BIOZ setups achieving similar impedance resolution performance compared with more four-electrode setups. The IC, fabricated in a 55-nm CMOS, can measure tissue impedances over a frequency range from 1 kHz to 1 MHz and can achieve a maximum input range of 24 kΩ (at the impedance measurement frequency) and a best-case resolution of 2 mΩ RMS (for a 100-Ω input). This increases to 14.0 mΩRMS for a 2-kΩ input impedance. The ASIC consumes 18.9-34.9 and 31.4-154.7 μW for the readout front-end and the CG, respectively. The power depends on the injected current amplitudes. A successful demonstration on the human body through a two-electrode (gel and dry) setup confirms the effectivity of the proposed work in a real use case.

1 December 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
QLQiuyang Lin
Qiuyang Lin
Shuang SongShuang Song
Shuang Song
RWRoland Van Wegberg
Roland Van Wegberg
WSWim Sijbers
Wim Sijbers
Dwaipayan BiswasDwaipayan Biswas
Dwaipayan Biswas
NHNick Van Helleputte
Nick Van Helleputte
This paper presents a low power, high dynamic range (DR), light-to-digital converter (LDC) for wearable chest photoplethysmogram (PPG) applications. The proposed LDC utilizes a novel 2nd-order noise-shaping slope architecture, directly converting the photocurrent to a digital code. This LDC applies a high-resolution dual-slope quantizer for data conversion. An auxiliary noise shaping loop is used to shape the residual quantization noise. Moreover, a DC compensation loop is implemented to cancel the PPG signals DC component, thus further boosting the DR. The prototype is fabricated with 0.18 m standard CMOS and characterized experimentally. The LDC consumes 28W per readout channel while achieving maximum 134 dB DR. The LDC is also validated with on-body chest PPG measurement.

24 July 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
NHNick Van Helleputte
Nick Van Helleputte
AEAniek J. G. Even
Aniek J. G. Even
Francesca LeonardiFrancesca Leonardi
Francesca Leonardi
SSStefano Stanzione
Stefano Stanzione
MSMinyoung Song
Minyoung Song
CHChris Van Hoof
Chris Van Hoof
The gastro-intestinal (GI) tract is a very important part of the human digestive system but remains largely inaccessible for unobtrusive monitoring. Ingestible electronic devices are a very interesting concept to address this need. This paper discusses the current state of ingestible electronic devices and explores the potential they hold to provide unprecedented insight by measuring several aspects of the complex bio-chemical processes that happen in the GI tract in real-time. This will require novel sensor technology capable of measuring relevant markers with adequate specificity and accuracy. In order to be able to scale this functionality down to a form factor of an easily digestible pill, ultra-low-power wireless interface electronics are needed. This poses certain challenges and innovation opportunities related to sensing, wireless communication and powering to enable the next generation of ingestible electronic devices. [2020-0164]