Shinhyung Kang

Shinhyung Kang

Auto-generated profile, based on publicly available information

Shinhyung Kang

GE Healthcare Co., Ltd., Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
ILIn Sook Lee
In Sook Lee
YSYou Seon Song
You Seon Song
YCYoung Jin Choi
Young Jin Choi
JKJeung Il Kim
Jeung Il Kim
KCKyung Un Choi
Kyung Un Choi
MNMarcel Dominik Nickel
Marcel Dominik Nickel
Lee IS, et al. Korean J Radiol. 2025 Nov;26(11):1054-1074. https://doi.org/10.3348/kjr.2025.0643

1 January 2024 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
MHMinhee Hwang
Minhee Hwang
SKShinhyung Kang
Shinhyung Kang
JLJi Won Lee
Ji Won Lee
GLGeewon Lee
Geewon Lee
Hwang MH, et al. Korean J Radiol. 2024 Sep;25(9):833-842. https://doi.org/10.3348/kjr.2024.0472


7 May 2026 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
HMHan Song Mun
Han Song Mun
SLSanghyeok Lim
Sanghyeok Lim
SKShinhyung Kang
Shinhyung Kang
Objective: To evaluate the effects of arm positioning and reconstruction algorithms on radiation dose and image quality of abdominal CT. Materials and methods: Abdominal CT scans were performed using a customized body phantom at 100 kVp with automatic tube current modulation based on noise indices (NI) of 9, 11, and 13 across seven arm positions: arms up (AU), arms down (AD), arms down with one or two-layered air cushions (ADAC, ADAC2), arms on the belly (AB), and arms on the belly with one or two-layered air cushions (ABAC, ABAC2). Images were reconstructed using filtered back projection (FBP), iterative reconstruction, and deep learning-based reconstruction (DLIR). Radiation dose was recorded. Quantitative image quality metrics included image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), sharpness, and structural similarity. Qualitative assessment of sharpness, noise, artifacts, and overall image quality was performed using fixed-dose AU-FBP images as the reference standard. Results: Compared with the AU position, radiation dose increased by up to 83% in non-AU configurations, with similar trends across all NI settings. In contrast, air cushion use caused only minor, configuration-dependent dose changes. Qualitatively, non-AU FBP images showed marked degradation, whereas DLIR enabled selected non-AU configurations to approach near-reference diagnostic quality. Air cushion-related benefits were modest overall but more apparent in AB than AD configurations. Conclusion: Arm positioning is the primary determinant of radiation dose and image quality in abdominal CT. When arm elevation is not feasible, DLIR effectively mitigates image quality degradation, while air cushions provide limited, configuration-dependent benefits. Relevance statement: When arms cannot be raised during abdominal CT, avoiding arms-on-belly and using air cushions may help maintain image quality without substantially increasing radiation dose, while deep learning image reconstruction further enhances diagnostic performance under restricted positioning conditions. Key Points: Arm positioning is a major determinant of radiation dose and image quality in abdominal CT. Arms-on-belly positioning produces poorer image quality despite increased radiation dose. DLIR improves image quality across arm positions but does not eliminate positioning-related degradation.