Andomar Bruno Fernandes Vilela

Andomar Bruno Fernandes Vilela

Auto-generated profile, based on publicly available information

Andomar Bruno Fernandes Vilela

Department of Operative Dentistry and Dental Materials Dental School Federal University of Uberlândia Uberlândia Brazil

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2017 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
CSCarlos José Osé Soares
Carlos José Osé Soares
AFAndre L Faria-e-Silva
Andre L Faria-e-Silva
MRMonise de Paula Rodrigues
Monise de Paula Rodrigues
AVAndomar Bruno Fernandes Vilela
Andomar Bruno Fernandes Vilela
CPCarmem S Pfeifer
Carmem S Pfeifer
AVAntheunis Versluis
Antheunis Versluis
Polymerization shrinkage stress of resin-based materials have been related to several unwanted clinical consequences, such as enamel crack propagation, cusp deflection, marginal and internal gaps, and decreased bond strength. Despite the absence of strong evidence relating polymerization shrinkage to secondary caries or fracture of posterior teeth, shrinkage stress has been associated with post-operative sensitivity and marginal stain. The latter is often erroneously used as a criterion for replacement of composite restorations. Therefore, an indirect correlation can emerge between shrinkage stress and the longevity of composite restorations or resin-bonded ceramic restorations. The relationship between shrinkage and stress can be best studied in laboratory experiments and a combination of various methodologies. The objective of this review article is to discuss the concept and consequences of polymerization shrinkage and shrinkage stress of composite resins and resin cements. Literature relating to polymerization shrinkage and shrinkage stress generation, research methodologies, and contributing factors are selected and reviewed. Clinical techniques that could reduce shrinkage stress and new developments on low-shrink dental materials are also discussed.

1 February 2017 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
CSCarlos José Osé Soares
Carlos José Osé Soares
MRMonise de Paula Rodrigues
Monise de Paula Rodrigues
AVAndomar Bruno Fernandes Vilela
Andomar Bruno Fernandes Vilela
ERErick René Cerda Rizo
Erick René Cerda Rizo
LFLorraine Braga Ferreira
Lorraine Braga Ferreira
Richard Bengt PriceRichard Bengt Price
Richard Bengt Price
The high irradiance and the different emission spectra from contemporary light curing units (LCU) may cause ocular damage. This study evaluated the ability of 15 eye protection filters: 2 glasses, 1 paddle design, and 12 dedicated filters to block out harmful light from a monowave (HP-3M ESPE) and a broad-spectrum (Valo, Ultradent) LED LCU. Using the anterior sensor in the MARC-Patient Simulator (BlueLight Analytics) the irradiance that was delivered through different eye protection filters was measured three times. The LCUs delivered a similar irradiance to the top of the filter. The mean values of the light that passed through the filters as percent of the original irradiance were analyzed using two-way ANOVA followed by Tukey test (a= 0.05). The emission spectra from the LCUs and through the filters were also obtained. Two-way ANOVA showed that the interaction between protective filters and LCUs significantly influenced the amount of light transmitted (p< 0.001). Tukey test showed that the amount of light transmitted through the protective filters when using the HP-3M-ESPE was significantly greater compared to when using the Valo, irrespective of the protective filter tested. When using the HP-3M-ESPE, the Glasses filter allowed significantly more light through, followed by XL 3000, ORTUS, Google Professional, Gnatus filters. The Valo filter was the most effective at blocking out the harmful light. Some protective filters were less effective at blocking the lower wavelengths of light (<420 nm). However, even in the worst scenario, the filters were able to block at least 97% of the irradiance.

18 December 2018 in Dental Traumatology
Verified
Journal Article
Closed access
PDF file
AVAndomar Bruno Fernandes Vilela
Andomar Bruno Fernandes Vilela
PSPriscilla Barbosa Ferreira Soares
Priscilla Barbosa Ferreira Soares
FOFabiana Sodré de Oliveira
Fabiana Sodré de Oliveira
TGTales Candido Garcia‐Silva
Tales Candido Garcia‐Silva
CECarlos Estrela
Carlos Estrela
CSCarlos José Osé Soares
Carlos José Osé Soares

22 November 2018 in Dental Traumatology
Verified
Journal Article
Closed access
PDF file
AVAndomar B. F. Vilela
Andomar B. F. Vilela
PSPriscilla B. F. Soares
Priscilla B. F. Soares
GAGuilherme A. Almeida
Guilherme A. Almeida
CVCrisnicaw Veríssimo
Crisnicaw Veríssimo
MRMonise P. Rodrigues
Monise P. Rodrigues
CSCarlos José Osé Soares
Carlos José Osé Soares

20 November 2020 in Dental Traumatology
Verified
Journal Article
Closed access
PDF file
GBGabriel Felipe de Bragança
Gabriel Felipe de Bragança
AVAndomar Bruno Fernandes Vilela
Andomar Bruno Fernandes Vilela
PSPriscilla Barbosa Ferreira Soares
Priscilla Barbosa Ferreira Soares
DVDaranee Versluis
Daranee Versluis
AVAntheunis Versluis
Antheunis Versluis
CSCarlos José Osé Soares
Carlos José Osé Soares

1 January 2021 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
LGLuis Gustavo González-Osuna
Luis Gustavo González-Osuna
CSCarlos José Osé Soares
Carlos José Osé Soares
AVAndomar Bruno Fernandes Vilela
Andomar Bruno Fernandes Vilela
MIMilena Suemi Irie
Milena Suemi Irie
AVAntheunis Versluis
Antheunis Versluis
PSPriscilla Barbosa Ferreira Soares
Priscilla Barbosa Ferreira Soares
Three-point bending test is the most common mechanical test used for quantifying the biomechanical quality of bone tissue and bone healing in small animals. However, there is a lack of standardization for evaluation of bone repair by cortical perforation. The aim of this study was to determine the influence of bone defect position in the proximal metaphysis of rat tibias during load application and different span configuration on the three-point bending test outcomes. Cortical defects with 1.6 mm diameter were created at a standardized location on the medial surface of 60 tibias of male Wistar rats. The animals were euthanized 7 days after surgery. Five specimens were used to create 3D models for finite element analysis using high-resolution micro-CT images. Two spans (6 and 10mm) and three positions of the bone defect in relation to the load application (upward, frontal and downward) were evaluated experimentally (n = 10) and in finite element analysis (n = 5). Maximum load (N) and stiffness (N/mm) were statistically analyzed with 2-way ANOVA and Tukey test (α = 0.05). The results demonstrated that span and orientation of the bone defect significantly influenced the fracture pattern, stress distribution and force versus displacement relation. Therefore, reliable outcome can be achieved creating the bone defect at 8 mm from the extremity of the proximal epiphysis; placing a 10 mm distance span and downward facing defect position to allow a better distribution of stress and more fracture patterns that reached the bone defect target area with less intra-group variability.